Loading...
12-0170 Plan Review Comments.pdfv CITY OF EDMONDS • 121 5" AVENUE NORTH • EDMONDS, WA 98020 PHONE: 425.771.0220 • FAX: 425.771.0221 • WEB: www.edmondswa.gov DEVELOPMENT SERVICES DEPARTMENT: PLANNING • BUILDING March 23, 2012 William Page pagearch@whidbeyisland.com RE: PLAN REVIEW COMMENTS FOR PLAN CHECK # 2012-0170 ADDITION/REMODEL AT 832 PINE STREET Dear Mr. Page, I have reviewed the above building permit application for the Planning Division. Before I can sign off on the permit, however, the following information needs to be clarified in a written response: 1. Datum point: It looks like the NW property corner is being used as the datum point for the project. If there is a permanent point of reference there, that's fine, but please label what it is. Otherwise, please select a permanent point, such the top of the nearby fire hydrant or the water meter near the western property line, for the datum. 2. Erosion hazard area: The site contains slopes identified as erosion hazard areas. As a result, according to ECDC 23.80.050.G, please submit the following information: "Report requirements for stable erosion hazard areas may be met through construction documents that shall include at a minimum an erosion and sediment control plan prepared in compliance with the requirements set forth in Chapter 18.30 ECDC." 3. Tree retention and protection: Please submit a tree retention plan prepared according to ECDC 18.45.045.A.6 and describe how the protection standards of ECDC 18.45.050.1-1 will be met. 4. Retaining wall and fence: A retaining wall and fence are proposed near the pedestrian entrance off the alley. For that portion of the structure within the required 10' side setback, the wall and fence may only be 3' and 4', respectively, according to ECDC 17.30.000.D. Please reconfigure the wall and fence to satisfy this code requirement. Retaining wall: A portion of the new eastern retaining wall is shown to extend into the 10' side property line setback on the south. Retaining walls may only be three feet in height above original grade within setback areas. Please provide a top and toe elevation for the wall at a location in the setback. 6. Elevations: Please label and include the heights for the average original grade, the proposed height, and the maximum allowed height on the Elevation sheets. All referenced code sections are available at the following website: http://www.mrsc.org/mc/edmonds/Edmondsnt.html. Please submit three copies of your updated site plan (one being reduced size of 11 x17 or smaller) and two sets of any updated sheets of the building plans. Please make all submittals to a Permit Coordinator, Monday through Friday, 8:00 am to 4:30 pm. If you have any questions, please contact me at (425) 771-0220. Sincerely, Odldl� Mike Clugston, AICP Associate Planner