Loading...
12-1098 Plan Review Comments.pdf th C ITY OF E DMONDS•1215A VENUE N ORTH •E DMONDS,WA98020 P HONE: 425.771.0220 • F AX: 425.771.0221 • W EB:www.edmondswa.gov D EVELOPMENT S ERVICES D EPARTMENT:P LANNING •E NGINEERING •B UILDING December 18,2012 Mr. Robert Rinehart Email: Rines54@comcast.net RE: PLAN REVIEW COMMENTSFOR PLANCHECK #BLD20121098 RINEHART CARPORT LOCATEDAT21127 SHELL VALLEY RD. Dear Mr. Rinehart: I have reviewed the above building permit applicationfor the Planning Division,and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: 1.SitePlan:Please make the following revisions/corrections to your site plan: a.You submitted two different site plans with your application.The two site plans indicate conflicting information in respect to thefootprint of the existing residence and in respect to theminimum distances from the existing residence and proposed carport to the property lines. It is the applicant’s responsibility to submit a true and accurate site plan. As such, please consolidate the information indicated on both site plans, and submit one site plan thatyou have verified to be true and accurate. b.Refer to enclosed Handout #B57 for a sample site plan and checklist of items that must be shown on your site plan. Please be sure to include all applicable items from this checklist on your revised site plan. c.The critical areas determination for your property (File No. CRA20100054) found that a stream may be located on/adjacent to the southernside of the property. Please indicate the location of this stream on your revised site plan. d.Indicate the lot area on the revised site plan. 2.Setbacks:The subject site is located within theRS-8 zone, which requires the following minimum setbacks: Street = 25’ (from the southern property line), Sides = 7.5’ (from the eastern and western property lines), Rear = 15’ (from the northern property line). One of the site plans submitted with the subject application indicates that the face of the garage is 32’ from the southern property line. This distance is consistent with the measurements indicated on the site plan that the City has on file from your 2010 building permit application for a patio cover over the rear deck (File No. BLD201000348). If the existing garage is in fact 32’from the southern property line, there would only be 7’ of width to construct a structure between the face of the garage and the 25’ street setback line. Please reduce the size of the proposed carport if necessary in order to comply with setback requirements, and provide accurate measurements on your revised site plan indicating the shortest distancesfrom the existing residence and proposed carport to all property lines. 3.Lot Coverage:Lot coverage is defined as the total ground coverage of all buildings or structures on a site measuredfrom the outside of external walls or supporting members or from a point two and one-half feet in from the outside edge of a cantilevered roof, whichever covers the greatest area. The maximum allowed lot coverage for the RS-8 zone is 35 percent of the net lot area. Please provide a breakdown of the lot coverage calculations (including the footprints of the existing residence, covered patio,proposed carport, and all other existing and proposed structures). Please indicate the proposed lot coverage in square feet and calculated as a percentage of the net lotarea. 4.Height:Please address the following comments regarding the height of the proposed carport: a.Provide height calculations on the site plan. Refer to Handout #B41 (enclosed) for guidance. Since the carport is proposed to be attached to the residence, the height rectangle for the height calculations must be the smallest rectangle that encompassesall of the existing structure together with the proposed carport. b.In addition to providing the height calculations, the height rectangle and elevations of all four corners of the height rectangle must be indicated on the site plan. c.Indicate the datum point (including what it is and its elevation) on the site plan. d.The maximum allowed height for the residence and attached structures within the RS-8 zone is 25feet above original grade. Indicate the average grade, maximum allowed height, and proposed height on the site plan as well asonthe building elevations. Please submit three copiesof your revised site plan and two copies of all revised building plan sheetsto a Development Services Permit Coordinator,Monday through Friday,between8:00 am and4:30 pm. If you have any questions, feel freeto contact me at (425) 771-0220. Sincerely, Development Services Department -Planning Division JenMachuga, Associate Planner Enclosures:Handouts#B41and #B57