14-0300 Plan review comments 2.pdfCITY OF EDMONDS ® 1215" AVENUE NORTH ® EDMONDS, WA 98020
PHONE: 425.771.0220 ® FAX: 425.771.0221 ® WEB: www.edmondswa.gov
DEVELOPMENT SERVICES DEPARTMENT: PLANNING ® BUILDING
April 9, 2014
June 16, 2014
Designs Northwest Architects
dan@designsnw.com
Dear Mr. Nelson,
I have again reviewed the above building permit application for the Planning Division. Before I
can sign off on the permit, however, the following information needs to be clarified in a written
response and through submittal of updated plans. Comments of June 16 are italicized:
1. Seismic hazard geotechnical report: Unaddressed. Please submit the requested
geotechnical report addressing the seismic hazard.
Because the western portion of the site has been identified as a potential seismic
hazard area, please submit a geotechnical report prepared according to the
requirements of ECDC 23.40 and 23.80 that describes the proposed project. The
report must be prepared in accordance with ECDC 23.40.090 and ECDC 23.80.050 and
must specifically address the requirements in ECDC 23.80.050.1-1 and ECDC 23.80.060.
2. Scale: Addressed.
The scale on Sheet A1.0 is shown as 1" = 20' but it seems it should be 1" = 10'. Please
verify.
3. Datum point: Unaddressed. Please label the datum point as noted below.
Please label the datum point used for height calculations on Sheet A1.0 and indicate
whether the point's elevation is actual or assumed.
4. Proiect Data - Setbacks: Addressed.
On Sheet A0.0, the setbacks shown in the Project Data box are incorrect. In the RS -6
zone, the street setback is 20', sides are 5' and rear is 15'.
5. South side setback: Addressed.
The south 5' side setback must be taken from the edge of the access easement.
Please verify.
6. Setback call out: Addressed.
1
Call out the actual distances proposed from each property line (or access easement) to
the closest portion of building or terrace post along that line.
7. Structural lot coverage: Addressed.
Structural lot coverage is calculated against net lot area so the coverage on Sheet A1.0
will need to be recalculated after subtracting out the area of the access easement.
This will lead to a maximum structural lot coverage allowed for the site of 3,421
square feet (11,500 —1,725 = 9,775 x 0.35 = 3,421).
Also, please verify that the structural lot coverage calculation for the proposal includes
the house, covered terraces, and covered porches. ECDC 21.15.110, "[c]overage
means the total ground coverage of all buildings or structures on a site measured from
the outside of external walls or supporting members or from a point two and one-half
feet in from the outside edge of a cantilevered roof, whichever covers the greatest
area."
8. Height calculations: Partially addressed. The height rectangle on Sheet A1.0 was not
revised. Please verify and update as necessary.
It appears on Sheet A1.0 that the height rectangle corners are set at the outer edge of
the roof as opposed to the walls of the building. Please move the rectangle corners in
slightly to enclose the building and terrace posts. Make any adjustments necessary to
the height calculations on Sheet A1.0 as well as the building plan elevation sheets
(A3.1 and A3.2). Also on the elevation sheets, please show the lines of average
original grade, proposed elevation of the house, and maximum allowed height for the
project.
9. Setback encroachment: Partially Addressed. Show the applicable property line
setbacks on Sheets A2.1 and S2.1 and verify that all structures other than those
allowed exceptions in ECDC 16.20.040(8) and (C) meet the setback requirements for
the RS -6 zone. For example, all arbor features (posts, wraps and beams) must meet
setback requirements. Update the patio dimensions on Sheet A2.1 as well.
It appears that the patio off the northwest corner of the house will not meet code
requirements for setbacks. For patios, ECDC 16.20.040.0 states, "Uncovered and
unenclosed porches, steps, patios, and decks may project into a required setback not
more than one-third of the required setback, or four feet, whichever is less; provided,
that they are no more than 30 inches above ground level at any point." The north side
setback is 5' so the patio may only encroach into the north setback a maximum of
1.65' rather than the 4' shown on Sheet A1.0. Please verify and revise the site and
building plans accordingly.
All referenced code sections are available here:
http://www.codepublishing.com/wa/edmonds/.
Please submit three copies of your updated site plan and two sets of any updated sheets of
the building plans. Please make all submittals to a Permit Coordinator, Monday through
Friday, 8:00 am to 4:30 pm (8:00 am to 12:00 pm on Wednesdays only). If you have any
questions, please contact me at (425) 771-0220.
Sincerely,
1"111t
J
it
Mike Clugston, AICP
Associate Planner