Loading...
14-0381 Plan review comments 2.pdfCrry OF EDMONDS ® 121 51h AVENUE NORTH ® EDMONDS, WA 98020 PHONE: 425.771.0220 ®FAX: 425.771.0221 ® WEB: www.edmondswa.gov DEVELOPMENT SERVICES DEPARTMENT: PLANNING ® BUILDING May 20, 2014 July 21, 2014 Todd Echelbarger todd@echelbarger.com RE: PLAN REVIEW COMMENTS 2 FOR PLAN CHECK # 2014-0381 NEW SFR AT 1037 MAIN STREET Dear Todd, I have again reviewed the above building permit application for the Planning Division. Before I can sign off on the permit, however, the following information needs to be clarified in a written response and through submittal of updated plans. July 21 comments are in italics: 1. Geotechnical report: Thank you for submitting the Earth Solutions report dated June 23, 2014. It was noted in the report that the geotech had not had the opportunity to review the associated grading plans; please have Earth Solutions review the grading and TESC plan (Sheet C2) and the associated drainage and utility plan (Sheet C1). Because the proposed 4' retaining wall will be constructed in a critical area or buffer, it must be designed by a licensed engineer. Submit section and elevation views for the wall along with design calculations and a letter from the engineer as identified in Building Division Handout #B62. Finally, on the Site Plan and Sheets C1 and C2, please show and label the 10' buffer and 15' building setback that the geotech identified on page 5 of the report. Because the northern portion of the site has been identified as a potential landslide hazard area or buffer, please submit a geotechnical report prepared according to the requirements of ECDC 23.40 and 23.80 that describes the proposed project in relation to the critical area. The report must be prepared in accordance with ECDC 23.40.090 and ECDC 23.80.050 and must specifically address the requirements in ECDC 23.80.060 and ECDC 23.80.070. 2. Datum point: ADDRESSED. Please use the CB rim at 202.56' for the TBM. It is very near the `chiseled square' but is a permanent point. Rework the height calculations on the Site Plan and Sheets A7 & A8 as appropriate. 3. Height calculations: ADDRESSED. Please revise the height rectangle on the Site Plan to include the porch posts at the south entry and the extent of the entry to the patio on the north. Revise the height calculations on the Site Plan and lines of average original grade, maximum allowed height, and proposed height on Sheets A7 & A8. 4. Setbacks: ADDRESSED. Show the required setbacks of the RS -6 zone on Sheet A4. 5. Trees and tree protection: UNADDRESSED. Please have a certified arborist or landscape architect determine the drip line of the trees along the north property boundary and show the drip lines for the retained trees on Sheet C2. Have that professional comment on the grading and placement of utility lines proposed to occur within the identified drip lines. Add the tree protection measures in ECDC 18.45.050.H(1)-(6) to Sheet C2 and any mitigation and protection measures identified by the arborist/landscape architect. Protected trees must be fenced to include at least the drip line of the tree according to ECDC 18.45.050.H. Please locate the drip line of all retained trees and show the proposed protective fencing in the drip line location on Sheet C2. 6. Retaining walls: ADDRESSED. For all retaining walls and rockeries on Sheet C2, show the top of wall/rockery and original grade at locations every 10' along the feature where located within a required setback. 7. Structural lot coverage: ADDRESSED. Maximum structural lot coverage is 35% for all single family residential zone but 36% is proposed on the Site Plan. Please verify and revise as necessary. According to ECDC 21.15.110, "[c]overage means the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point two and one-half feet in from the outside edge of a cantilevered roof, whichever covers the greatest area." All referenced code sections are available here: http://www.codepublishing.com/wa/edmonds/. Please submit three copies of your updated site plan and two sets of any updated sheets of the building plans. Please make all submittals to a Permit Coordinator, Monday through Friday, 8:00 am to 4:30 pm (8:00 am to 12:00 pm on Wednesdays only). If you have any questions, please contact me at (425) 771-0220. Sincerely, Mike Clugston, AICD Associate Planner