Loading...
14-0778 Plan review comments 2 w mark up.pdfCITY OF EDMONDS ® 1215" AVENUE NORTH ® EDMONDS, WA 98020 PHONE: 425.771.0220 ® FAX: 425.771.0221 ® WEB: www.edmondswa.g DEVELOPMENT SERVICES DEPARTMENT: PLANNING ® BUILDING August 11, 2014 September 18, 2014 David Kleven deckpro.decks@comcast.net RE: PLAN REVIEW COMMENTS #2 FOR PLAN CHECK # 2014-0778 NEW DECK, PATIO COVER AT 8534 210TH PLACE WEST Dear Mr. Kleven, I have again reviewed this building permit application for the Planning Division. The following information in italics still needs to be clarified in a written response and through submittal of updated plans. I marked up a copy of the 9/17 site plan with the comments numbers for reference: 1. Geotech buffer and setback: The buffer and setback shown on the September 17 resub are cumulative; however, that distance (10'+15') does not equal the 25' distance shown immediately to the south to the covered patio. Please revise and show the measurements to be the some if that's what they are. On the Plot Plan, please show and label the cumulative 10' buffer and 15' setback distances from the top of the steep slope that are identified on page 6 of the Galli Group's geotechnical report dated July 10, 2014. 2. Zoning setback: If the site plan is to scale, it appears that the patio cover will be closer than 5' to a portion of the south property line. Please verify and revise the site plan as necessary. The proposed patio cover must meet the 5' side setback established by PRD -02-171/P- 02-172. Please call out the actual distance proposed from the southwest patio cover post to the south property line. Also, show how the eaves comply with the setback exception in ECDC 16.20.040.13 which indicates that eaves may not project into a required setback by more than 30 inches. 3. Lot coverage: Is the 'lot coverage' shown structural or impervious? It seems to be structural but please label accordingly. 4. Height calculations: Height cornerA looks to have been updated correctly but corner 8 needs to be positioned as shown on the mark up. Revise the height calcs as appropriate and then show the lines of elevation for the 'average original grade, 'maximum allowed height; and 'proposed height' of the patio cover on the 'Front View' elevation. It appears that the 'actual' or 'proposed' height of the patio cover also needs to be updated on the plot plan. Height corners A and B need to be moved to the west to enclosed the patio cover. Update the height calculations as necessary based on new elevations, as appropriate. On the elevation drawing (`front view') show the line of elevation for the `average original grade', 'maximum allowed height', and 'proposed height' of the patio cover determined from the height calculations shown on the Plot Plan. All referenced code sections are available here: http://www.codepublishing.com/wa/edmonds/. Please submit three copies of your updated site plan and two sets of any updated sheets of the building plans. Please make all submittals to a Permit Coordinator, Monday through Friday, 8:00 am to 4:30 pm (8:00 am to 12:00 pm on Wednesdays only). If you have any questions, please contact me at (425) 771-0220. Sincerely, Mike Clugston, Clugston, AICP Associate Planner S/ 7 PLA r1i 4 Lnxy S 1Rawmjr=?-- 053q, X10 P1-- -S V) IE-OITADO,D,�j \Nfk - ?Anet..4 aloo,'70ooemsem zc) 4A Ittiol AH -2- L-0-r co v t� Wr N -AkCjj�- 115911, OD OF Zone Sides ...... Rear Offier pt,�P-vf �y x L� I VIA C I -J'br ev I Po. 12i Tv I'D 44F- j C--flj 9,0u, - -TOG) . I Ci cn, vle4- N -6776 R E SEP 17 2014, ary'i r" �YTAIDNDS