Loading...
15-0278 Lake Ballinger Planning Comments.doc CE ITY OF DMONDS th • 1215 AN•E,WA98020 VENUE ORTH DMONDS P: 425.771.0220 • F: 425.771.0221 • W: www.edmondswa.gov HONEAXEB DSD: P•B EVELOPMENT ERVICES EPARTMENTLANNING UILDING April 7, 2015 Gabbert Architects Planners c/o David Pagel rd 18422 103 Ave NE Bothell, WA 98011 RE: PLAN REVIEW COMMENTS FOR BUILDING PERMIT #BLD2015-0278 AND BLD2015-0279 NEW RESIDENCE AND DETACHED GARAGE AT 7317 LAKE BALLINGER WAY Dear Mr. Pagel I have reviewed the above building permit application for the Planning Division, and it was found that the following information, corrections, or clarifications need to be addressed before review can continue: Critical Areas 1. : The project site abuts Lake Ballinger. The critical area checklist associated with the address (CRA-2015-0016) noted this and indicated the possible presence of wetlands adjacent to the lake. In addition, there is a mapped Zone A flood hazard at the subject location according to FIRM Map Panel 1315. As a result, critical area studies are required as part of this development project. While a wetland report was included with the building permit application several items are absent from the report that are required by code. In addition to the wetland report a flood hazard study prepared according to Chapter 23.70 Edmonds Community Development Code (ECDC). Proposed rain garden in the wetland and wetland buffer 2. : A rain garden and associated landscaping is shown within the Category IV wetland and the associated buffer per Grading Plan, Stormwater Site Plan and Landscape Sheets submitted to the City on March 3, 2015. According to ECDC 23.50.040.F.8.c: Storm water management facilities, limited to outfalls, pipes and conveyance systems, storm water dispersion outfalls and bioswales, may be allowed within the outer 25 percent of a standard or modified buffer for Category 3 or 4 wetlands only; provided, that: i. No other location is feasible; and ii. The location and function of such facilities will not degrade the functions or values of the wetland. Rain gardens are not a permitted use within the wetland or wetland buffer. The rain garden location will need to change with the exact location determined by your engineers and approved by the City’s Engineering Division of Public Works. If a stormwater facility will be located in the wetland buffer with landscaping, the associated Wetland Delineation Report completed by Altmann Oliver Associated, LLC will need to address the potential stormwater facilities and any associated landscaping. Please have the consultant review any proposed stormwater plans and landscaping that would occur in the wetland buffer and provide an addendum to their December 28, 2011 report describing the impact of the stormwater on the wetland in accordance with sub (ii) referenced above. If the functions and values of the wetland would be degraded by the location of an allowed stormwater facility, the consultant will need to propose mitigation based on the requirements of ECDC Section 23.50.050 and Sections 23.40.110 – 130. Wetland buffer reduction: 3. The wetland report notes that a Category IV wetland is present on the property with an associated buffer of 35 feet. A 15-foot building setback is required in addition to the wetland buffer per ECDC 23.40.280. The site plan submitted with the building permit notes a 17 ½ foot wetland buffer with an associated 15-foot building setback. A reduction in the standard 35-foot wetland buffer is permitted in ECDC 23.50.040.F.3. However, the wetland report does not address any of the criteria required for the wetland reduction. Please amend the report to address the requirements of ECDC 23.50.040.F.3 or adhere to the standard 35-foot buffer. Height Calculations: 4. Indicate the location and elevation of the datum point used for the height calculations on your site plan. Also, please correct the maximum height allowed for the garage, 15 feet instead of the 25 feet as noted on the site plan. In addition to amending the site plan, please verify the height calculations (average grade, actual height, and maximum height) are accurately reflected on the house and garage elevations. Lot Coverage: 5. Lot coverage is defined as the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members excluding a maximum of 30” of eaves. Please provide a breakdown of the lot coverage amount shown on the site plan. Setbacks: 6. Edmonds Community Development Code Section 16.20.040.C permits uncovered and unenclosed porches, steps, patios, and decks into a required setback not more than one-third of the required setback, or four feet, whichever is less; provided that they are no more than 30 inches above ground level at any point. A portion of the front entry to the house is located within the front yard setback and is covered by the second story roof. The portion of the porch within the setback may be covered by eaves up to 30 inches in width, however, the site plan shows a portion of the porch covered in the building setback beyond the permitted 30 inches. Please amend the site plan and other relevant building pages accordingly to comply with the above cited code section. A portion of the north wall of the detached garage is shown on and slightly within the 15- foot building setback from the wetland buffer. Pursuant to ECDC 23.40.280 the wall of a building is not permitted within the setback. Please amend the site plan and garage detail plans accordingly to comply with the cited code section. Please Note: Additional comments from the Building Division and Engineering Division may require additional changes to the site plan beyond those discussed above. A revised site plan addressing the above cited issues should be completed once you have received comments from the other reviewing divisions. Please submit three copies of your revised site plan (including one reduced copy) and two copies of any revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays, Tuesdays, Thursdays, and Fridays between 8:00am and 4:30pm, and Wednesdays between 8:00am and noon. If you have any questions, feel free to contact me at (425) 771-0220. Sincerely, Development Services Department - Planning Division Sean Conrad Associate Planner