Loading...
15-0994 Plan review comments #3.pdfCITY OF EDnnoNDs • 1215th AVENUE NORTH • EDMONDS, WA 98020 l/ PHONE: 425.771.0220 • FAX: 425.771.0221 • WEB: WWW,edrnondswa. ov DEVELOPMENT SERVICES DEPARTMENT: PLANNING • BUILDING January 27, 2016 Warren LaFon warrenlafon@earthlink.net RE: PLAN REVIEW COMMENTS #3 FOR PLAN CHECK # 2015-0994.40 20 -15 -0 - ADDITION AT 160 W. DAYTON AND SHED AT 154 W DAYTON' (HARBOR SQUARE ATHLETIC CLUB) Dear Mr. LaFon, I have reviewed the December 14, 2015 resubmittal in support of the referenced building permit applications. It is noted that building permit BLD20150995 for a shed has been withdrawn — all plan documents need to be updated to show the removal of that element. For the remaining permit, please submit updated plans with changes called out as appropriate addressing the updated scope of BLD20150094: 1. HVAC units: Four new HVAC units are now proposed on the roof - please provide height calculations (refer to Handout B41 for further details on what needs to be shown). It should be noted that the contract rezone limits height in the development to 35 feet. 2. Tennis court -to -parking lot: Changing the tennis court to a parking area cannot be approved because it is not keeping with the current critical areas ordinance. The wetland report from Wetland Resources dated December 3, 2015 describes the change as an Allowed Activity per ECDC 23.50.020.E which states: Permitted alteration to a legally constructed structure existing within a wetland or wetland buffer that does not increase the footprint of development or impervious surfacing or increase the impact to a wetland or wetland buffer. However, the tennis court is not a 'structure' according to the Edmonds Community Development Code: Structure means a combination of materials constructed and erected permanently on the ground or attached to something having a permanent location on the ground. Not included are residential fences less than six feet in height, retaining walls, rockeries, and similar improvements of a minor character less than three feet in height. (ECDC 21.90.150) Because the tennis court is not a structure "erected" permanently on the ground, changing the court to a parking area cannot be considered to be an Allowed Activity, Further, updating the wetland report to use buffer width reduction or buffer averaging could also not be approved. The Category 1 buffers of the Edmonds Marsh cannot be reduced according to ECDC 23.50.040.F.3. Similarly, buffer averaging per ECDC 23.50.040.F.4 is not possible because all of the criteria for reduction could not be met in this case. 3. Additions to locker room/changing room: These proposed additions cannot be permitted due to the contract rezone conditions that are in place for the development. The language of the rezone contract in PLN19790004 is specific with regards to changing building square footages: The number, arrangement, and shape of buildings may be altered without increasing the gross floor area, general distribution of buildings, or significantly altering the looped circulation system. (Page 2, Condition 1.A.1) The proposal for an approximately 645 sq. ft. addition to Harbor Square Athletic Club would increase the gross floor area and therefore does not meet the referenced condition. A change to the contract restrictions would need to be made through the rezone process before any further additions could be permitted. All referenced code sections are available here: tfp�fwww.code ublishin .com wa edmonds . Please submit three copies of your updated site plan and two sets of any updated sheets of the building plans. Please make all submittals to a Permit Coordinator, Monday through Friday, 8:00 am to 4:30 pm (closed Wednesdays for permit intake). If you have any questions, please contact me at (425) 771-0220. Sinerely, 1//7 Mike Clugston, AICP Associate Planner Cc: Bob McChesney, Executive Director Port of Edmonds 336 Admiral Way Edmonds, WA 98020 September 30 comments 1. Scope of work: Update the scope of work for the project to include changing the existing south tennis court to parking. Indicate how many parking stalls are to be removed and how many replaced. 2. Site : Please submit a true and accurate site plan. Show and label all existing features and call out proposed changes, including the proposed bathroom addition where the parking stalls are currently located under the building which was left off the September 10 resub. 3. Wetland report: Please submit a wetland report prepared by a qualified professional in accordance with ECDC 23.50.030 and 23.40.090 that identifies the scope of the tennis court/parking lot project, impacts to the wetland and buffer, and proposed mitigation in accordance with the critical areas codes in ECDC 23.50 and 23.40. September 3 comments 1. Addition to Athletic Club: UNADDRESSED. The larger Harbor Square site is subject to a contract rezone recorded on AFN8005060198. Covenant A.2 on page two of the rezone contract states: "Parking areas may be modified without reducing the number of spaces provided, the general distribution of spaces, or the amount of landscaping." It appears 2-3 parking spaces are proposed to be removed as part of the addition under the south portion of the building. At the same time, while not called out on the site plan, it appears that 46 additional parking spaces are proposed in a revised area near the outdoor tennis courts — the one tennis court is shifted north and an extensive new parking area is proposed. While this would appear to resolve the parking space issue, the presence of Edmonds Marsh and its buffer prohibit this site revision. Creation of additional impervious surfaces within the 200' wetland buffer is an alteration to a critical area. While mitigation can in some cases be offered for such alterations, the proposed work cannot be mitigated for because buffer width reductions are not allowed for the Marsh buffer since it is not a Category 3 or 4 wetland (ECDC 23.50.040). If the parking spaces removed by the proposed addition can be created elsewhere near the building on existing impervious area (not in areas of removed landscaping), it is possible the addition could be approved. As proposed, however, the addition cannot be approved. The revision to the tennis court and parking near the Marsh cannot be approved either. 2. North windows: New windows are shown on Sheet A-4. Will the materials used match the existing windows on the north facade? If not, what materials will be used? 3. Shed: If the addition proposal is abandoned, please revise all plan sheets to show the shed permit request only.