Loading...
15370-R-TRAF-2017-11-09-Driveway Access Addendum re 2 lots-Popp.pdfWilliam Popp Associates November 9, 2017 To: Phong Le Clear Vision Homes, Inc. Renton, WA C/o: Katy Dacanay Attorney at Law Wilson & Neal, PLLC From: William Popp Jr. Senior Transportation Engineer William Popp Associates Transportation Engineers/Planners (425)401-1030 FAX (425) 401-2125 e-mail: info@wmpoppassoc.com Subject: Edmonds Short Plat: 18227 801h Ave W Two Single -Family Residential Lots (formerly 3 lots) City of Edmonds, WA Re: DRIVEWAY ACCESS SAFETY ASSESSMENT UPDATE A Driveway Access Safety Assessment Update study was submitted to the City dated 10/28/15. In that analysis, the development included three single family lots with all three lots taking access to 80th Ave W at the north end of the site. This access location became the recommended access point based on the aforementioned safety analysis. The 10/28/15 analysis included discussion of: Roadway Inventory, Nearby Residential Driveways, Site Trip Generation, Sight Distance, and Accident History. The subsequent update of the subject plat from 3 single family lots to 2 single family lots is discussed herein. The sections of the 10/28/15 report identifying roadway inventory, nearby residential driveways, and accident history would remain unchanged as a result of the plat change from 3 lots to 2. However, the trip generation section's estimate of trips would drop from 14-400 Building . Suite 206 . 14400 Bel -Red Road . Bellevue, WA 98007 Driveway Access Assessment Study Update 18227 80`h Ave W 1119117 Page 2 30 daily trips to 20. The net new trips to/from the plat was formerly 20 daily trips and now it is 10. The estimated traffic increase (gross or net new) to the surrounding street system should be considered insignificant in either case. The primary focus of the 10/28/15 analysis was to identify the optimum shared use access for the plat. The results of that traffic safety analysis concluded that the recommended access for all the lots (formerly 3) would be at the north end of the site to 80th Ave W. With the current proposed 2-lot plat layout, the plat's shared access remains at the same location. The current layout of the plat's shared access is shown in Attachment 1 (TEC Drawing 3.1) Therefore, it is our conclusion that the findings and conclusions, as well as the (mitigation) recommendations noted in the 10/28/15 are still applicable. Attachment 1. TEC Drawing 3.1 — displays Lot 1 and Lot 2 shared access detail William Popp Associates Page 2 HE IM SEC I('„ nTp 27H, RHG 4E� mmll v,r I I 1.. I � j I.. I O (TYP) I I i I � % 10 + (10 I IE 324.50 RIM 318.33 n/c i, ,) IE 316.35 P P-�_�� . %ED 4 ...... ..�10 SS o SS SS o SS, SS ]T�TJ - P P \ P \ \ \ I'. — _ JJJ_i�d'IJ�JO�� �'J_WJJJ_ _�IJJ_II JJJJ�JJ J 00 J N G —�� N �— ��:�h. M M J M' I I r M I I I I M_ to N J �`,n S�J / \ \ JJJJJJ'J�JJJJJ��JJJ J. �.J JJ JJJ_J _J wJ 2+5 I. OWERI JJJJJJJJJJJJJJ JJJ \ �> J J J-1J, JJ�JJ�JJ J - - - W/LUMINAIREIQ LE I �41D WS WS ° WS JJ�J J. °JJ J I TRANSFORMER I `n \ �?, �— J J J ����JJJI J�J,,J 7 J I I g'� .-teas I JJJ l D I �OJJ� JJJJ ► III JJJJJ JJJJJJJJJJ s' II WATER ':': :':':'':':':':(r JJ�JJJJJJJJ I CB #1 TYPE 2 XOO f METER J imIJ J J J J J J J I I L a I (DRYWELL) / JJ,JJJJJJJJ i I N� 1� 0' ° I RIM 319.00 ��_.. L� JJJJJJJJJJ I I I IE 316.00 J J J -J J SXISTING HOUSE I JJ-1J I 5 ' Q " I JJJ (18227 80TH AVE W I cb i 26.50' '' 1 J J J EDMONDS, WA 98026) % � I N 66 LF 6" SD SD STKJ 0 T 2 _ X I.... o _ _ JJJ I � I rj 0.120 ft/ft(� IE 31�.618,636 SF _I_ ( \ I' ;.L I LOT 1 Jrr I I I FUTURE HOUSE �i... 4.0' n Tiro Tv REMAIN : J: I , __,- ..'.'. ''' a• . � I 18,555 SF METER •:. �:'... <' . I I I �' F.F. 322.0 (MIN) � o ---- / �• - I /���7L/ A. I25.0' I - OVA I `I ..... N..' ` / + I III / �. It.. I L _ _ _ _ _ I / 50.00' i1//11,' f ............... .............I....... kk .a d ASPHALT DRIVEWAY �� 'TO BE REMOVED) I N \ \\ " = = WATER.' .......I I N z o ° A I N 8/0 .BOX .. VIAILB(~ — — — — — — — _ \ } f12"CHES� o —------- FENCE RAIL o a 1 I 5' WOOD FEN(`E a SSMH ' "' 1 \ RIM= 342.80'-- ' T / 8CE TERN OF I O ADVIAI ADCd CHANNEL=328.08' I .'I'.' _ ^-77 --////////, n K11 IKIV CCAVl' AnAI .nn Zen Onn lln. Inn •.,' 1.... ...... .... --- ...... n' :..• •.a. 1.. .. Q.....NII................. a. •• i'.: .. I ... .... .... ..._.... .. ....... +r....... .. / ....'.. . N GRADING AND DRAINAGE PLAN SCALE: 1 "=20' 34 34 33 33 32 32 31 31 ATTACHMENT 1 RIM 326.50 ACCESS DRIVES GRADING PROFILE HSCALE: 1 "=20' // VSCALE:1 "=5' W OIL/WATER SEP CALL BEFORE YOU DIG 811 FOR FIELD OF UNDERGROU DCATION UTIILTIES GRAPHIC SCALES 0 10 20 40 (HORIZONTAL) 1 in. _ 20 ft. 0 2.5 5 10 (VERTICAL) 1 in. = 5 ft. IMPERVIOUS AREAS SUMMARY: LOT LOT AREA 35% MAX LOT COVERAGE RESTRICTED FOOTPRINT 1 18,555 SF 6,494 SF 5,389 SF — 2 18,636 SF 6,523 SF 3,838 SF 37,191 SF 13,017 SF 9,227 SF +I 1 SHEET NOTES: 1. AMEND ALL SOILS THAT ARE TO BE USED FOR FINISH GRADE SURFACE PER WSDOE SMMWW BMT 5.13 CONSTRUCTION NOTES: CATCH BASIN TYPE 1 0 CATCH BASIN TYPE 1 WITH "FURN-DOWN ELBOW" OIL/WATER SEPARATOR AND DOMED GRATE PER DETAIL 3/SHT 3.1 CUT-OFF TRENCH PER DETAIL 1 /SHT 3.1 D4 22'x22'x3' INFILTRATION DRY WELL PER DETAIL 4/SHT 3.1 6"0 STORM DRAINAGE SERVICE PIPE FOR CONNECTION OF ALL ROOF DRAINAGE @6) 6"0 PVC OR DOUBLE WALLED CPEP STORM DRAIN PIPE 0.020 ft/ft MINIMUM SLOPE (UNLESS OTHERWISE INDICATED) ( 7� LINE SIZED CLEANOUT PER DETAIL 1/5.1 (� 27' DISPERSION TRENCH SIMILAR TO DETAIL 2/5.1 ni 27'x100' NATIVE GROWTH FLOW AREA (AMEND SOIL & REPLANT AS NECESSARY) 0;1 CONCRETE WEDGE CURB FLOWLINE (,11 DRIVEWAY CROSS SLOPE - SEE TYPICAL SECTION 2/SHT3.1 IE (IN) -EXISTING GRADE 'DEPRESS TRENCH GRADE SLIGHTLY BELOW SURROUNDING MAINTAIN LEVEL GRADE +I AT OVERFLOW EDGE 11 0000000000 0coo 000 2" MINUS °o°o°o°o°o°o°o° WASHED RIVER o°o°o ROCK °°° °° FILTER FABRIC PROTECTION o°o°o°o°o°o°o°o 0°0°0°0° °00 0 °°°°°° ° -PEA GRAVEL OR FREE °°°° °°°° DRAINING CRUSHED ROCK 0°O°O ODOD 000000000000 °o °°o°o°o°o°o°o°o 0 0 0 0 -4"� PERFORATED 1' I PVC DRAIN PIPE SURFACE CUTOFF TRENCH SCALE: N.T.S. WEDGE CURB- SIDE SLOPE TO N PL APPROX 2% (TYP) VARIES VARIES `CATCH SLOPE TO EXISTING VARIES TYPICAL DRIVEWAY GRADING SECTION SCALE: 1 "=5' CB TYPE 1 OR OTHER SD STRUCTURE AS INDICATED ON PLAN NOTES: 1. TRAP TO BE MADE OF 23 Go. (0.0336") GALVANIZED SHEET METAL OR 18 Go. (0.050") ALUMINUM. 2. ALL JOINTS TO BE SEAMED AND SOLDERED, OR WELDED. 3. ALL LONGITUDINAL JOINTS TO BE RIVITED, OR WELDED. 4. DIAMETER "D" IS NOMINAL DIAMETER OF OUTLET PIPE. A — OUTLET TRAP CB W/ OIL -WATER SEPARATOR ELBOW N.T.S. SD PIPE PER PLAN 22' Z a� 00 J O Q m M J M O W 3:oE 0 FINISH GRADE WASHED ROCK 3/4" TO �6" PVC PERFORATED DRAIN 1-1/2" PER COE STD DETAIL PIPES (8) ARRAYED FROM —i CENTER OF DRYWELL CB ANTICIPATED ELEVATION OF HIGH GROUND WATER OR DENSE SOILS INFILTRATION DRYWELL 4 SCALE: 1 "=5' Taylor Engineering Consultants 485 Rainier Blvd N, Ste 201 P.O. Box 1787 Issaquah, WA 98027 tel. 425-391-1415 Project: EDMONDS 2-LOT SHORT PLAT 18227 80TH AVE W EDMONDS, WA 98026 Developer: Phong Le 1123 SW Maple Ave, Suite 110 Renton, WA 98057 206-851-7777 Job Data: TEC Job # 629-DDD Designed.- WN T Checked.- LM T Authorized Use: This drawing is issued for use in the titled project only. It sholl not be used for any other purpose without the express authorization and/or adaptation by TEC. Permit Agency: CITY OF EDMONDS Issued for: PERMIT 10/25/17 Rev. Date Sheet Title: w GRADING AND > DRAINAGE PLAN Q J Sheet No: Q Z 2LUI 301 J 0- Sheet of