16108 75TH PL W.PDF1111111111111115036 16108 75TH PL W • 'a 16106 7S�Z-kl CITY OF EDMONDS STREETRA F 121 5TH AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 COMMUNITY SERVICES DEPARTMENT Public Works • Planning/Building • Parks and Recreation • Engineering • Wastewater Treatment Plant jnC.18°1� November 2, 1998 RECEIVED NO V 2 - 1998 Mr. Mark Dodds, P.E. EN,'C1i1l!zr-:,F?ING Dodds Geosciences, Inc. Post Office Box 2385 Kirkland, Washington 98083 RE: Nguyen SFR @ 16108 75th Avenue West; Lot, 3 S23-90, Plan Check #98-356 1 Dear Mr. Dodds, Regarding your soils report dated 5/26/98 for the subject property, included in the analysis are the following statements; "the City of Edmonds is responsible for ensuring stability of their property along the roadway" and "...A permanent soldier pile wall ... to support the slope -behind the house is required. This will provide some stability to the slope although the City of Edmonds must stabilize the road subgrade above the property, and they are responsible for their road." Although the Geotechnical Report Guidelines included in the Earth Subsidence Landslide Hazard packet requires that the soils report for Meadowdale development include an analysis of potential impacts on surrounding adjacent properties, it does not require or force adjacent properties to be improved or stabilized in order for a particular site to be developed. Rather,. geotechnical improvements must installed within individual sites in order for the geotech of record to render the decision of a safe and stable site as defined in City Ordinance #2661. Regardless of whether the City or a private citizen is the adjacent property owner, Mr. Nguyen must install those improvements that you require, on his own property, in order for you,to determine that the site is safe and stable. If you believe that adjacent property must be stabilized before the Nguyen property can be rendered safe and stable, then the building permit could not be issued at this time since no future projects are under consideration for this area as noted on the City six year Capital Improvement plan. Please be aware, the City Engineer Jim Walker, in a letter dated 5/21/98 has already informed Mr. Nguyen of this information. Please clarify for the City in writing, whether work is required on 75`h Place West before the Nguyen site can be certified as stable. e Incorporated August 11, 1890 Sister Cities International — Hekinan, Japan Mr. Dodds Page Two November 2, 1998 As a reminder, City Ordinance 42661 requires the geotechnical engineer to certify that the site is stable in order for the City to grant a building permit. An unreasonable risk of damage to a single family structure is that the probability is greater than 30% in a 25 year period. If you have any questions please feel free to contact me at 425-771-0220. Thank you, Jeannine L. Graf Building Official Cc: Fredrick Chen @ 3855 26th Ave W, Seattle 98199 Chien Ding Nguyen @ 18311 71s` Ave W, Lynnwood 98037 Bill Evans,. Landau Associates 'Jim -Walker, City'Engineer - Paul Mar, Community Services Director r•{f . 04/ 26/ 1999 12: 51 425828 DEOSCIENCES INC. Post Office Box 2385 Kirkland, WA 98083 Telephone (4Q5) 827-1084 Facsimile (425) 828-9443 Chien Dinh Nguyen 18311 — 71 'd Avenue West Lynnwood, WA 98037 HAVE A GREAT 4 PAGE 01 16 STREET FILE , RECEIVED AUG , 3,999 DEVELOPMENT SERVICES CTFL CITY OF EDMONDS CITY y Subject: Addendum No. 2 160XX 75's Place West Edmonds, Washington Reference: Initial Geotechnical Review By Landau Associates, Inc., dated 12/15/98 Dear Mr, Chien: Job Number 8042 February 19, 1999 This letter presents recommendations to allow construction of your family residence. i Pro sed single - Po � The current proposal is to incorporate a soldier pile wall into the eastern wall of the residence and then backfill behind the soldier piles to the elevation where a 4:1 (Horizontal:Vertical) slope is created. This proposal will provide a safe environment for the residence. The soldier piles should consist. of steel H-beams which are embedded in concrete -filled drilled holes of adequate depth. The soldier piles should stick up above the finish exterior grade a minimum of one foot. As soldier piles do typically shift on the order of one half inch or more, we recommend the structural engineer rigidify the frame of the house behind the soldier piles to decrease potential movement. The soldier pile wall should consist of minimum twenty -four -inch -diameter steel -beam - reinforced concrete augercast piles embedded a minimum depth of fifteen feet into the underlying hard clayey soils. Minimum pile lengths of forty-five feet should be anticipated. Permanent lagging should be utilized between the piles. Provisions should be made to accommodate drainage which may percolate through the wall. I nu6. V G 40 CHIENADDENDUM.NO. 21 February 19, 1999 Job Number 8042 Page 2 The following design pressures can be used by the structural engineer for the structural design of the wall: 1) An Active Equivalent Fluid Pressure of 65 pounds per cubic foot (pcf) acting from the top of the pile to a depth of five feet below the lower floor slab elevation. 2) A Passive Equivalent Fluid Pressure of 125 pcf acting over 1.5 times the pile diameter starting at a depth of five feet below the floor slab elevation and extending to a depth of twenty feet below the floor slab elevation. 3) A Passive Equivalent Fluid Pressure of 225 pcf acting over twice the pile diameter starting at twenty feet below the lower floor slab elevation. Criteria given for installation and inspection of the augercast soldier piles is equivalent to that presented in our original report for augercast pile foundations. The slope on either side of the residence can either be reinforced with additional soldier piles or perhaps with a geogrid buttress depending on the required bearing pressure at the base of the buttress. We disagree with the conclusions of Reference No. 1 that some sort of deep landslide mass may exist through the subject site. To come to this conclusion requires ignoring encountered subsurface conditions. If there are any questions concerning this letter, please contact the undersigned at (425) 827-1084. Thank you, DODDS Geosciences Inc. M . Mark K. Dodds: P.E. 07/T2/20�1•, ""17 4257713549 ZIPPER ZEMAN ASSOCIA PAGE 02 10leY A/ Zipper Zeman Associates, Inc. Geotechnical and Environmental Consulting STREET BILE City of Edmonds Community Services Department 250 — 5th Avenue North Edmonds, Washington 98020 RECEIVED Attention: Jeannine Graf, Building Official J-76' July 12,.200' JUL 12 2001 Subject: Supplement to Geotechnical Review Proposed Nguyen Residence DEVELOPMENTCITY OF EDMONDS CTR. 16108 75th Avenue West Edmonds, Washington Dear Ms. Graf: This letter supplements our August 10, 2000 geotechnical review for the reference project. Additional submittal information was received with your transmittal dated March 161 2001. The plan review number for this project is 00-287. i A letter from Dodds Geo Sciences, Inc. dated March 16, 2001 was submitted. The lettetl responded to specific items addressed in our August 10, 2000 geotechnical review. Structural and architectural plans were submitted, with limited revisions from the previously reviewed set. Conclusions and Recommendations The March 16, 2001 Dodds letter implies that the soldier pile retaining wall will stabilize' the present instability of the road prism. Note 3 on the structural plans for the soldier pile wall i not consistent with this conclusion. We recommend that this be clarified, and the note deleted The stairs on the slope above the wall are subject to damage if soil movement occurs; mitigation recommendations should be provided. The geotechnical engineer provided additional information, including the log of a additional boring and the results of stability analyses, sufficient to confirm that geotechnic� analyses of the planned soldier pile retaining wall along the east side of the property wer completed in accordance with generally accepted engineering practice. However, the structure plans contain information that contradicts the recommendations for the wall contained in th August, 2000 Dodds report. The pressure diagram referred to in the Dodds March 16, 2001 lette was not submitted for review. We recommend that the structural plans for the project be revised to reflect the wall design recommendations of the June, 2000 Dodds report (unless modifications to the design are reviewed and analyzed by Dodds). Because of the critical nature of this wall, and because the structural plans and geotechnical report don't correspond to each other on specifics of the wall 18905-33'd Avenue Wcst, Suitt 117 Lynnwood, Washington 98036 (425) 771 - 3304 07/12:�2001 '08:17, 4257713549 ZIPPER ZEMAN ASSOCIA PAGE 03 ,Nguyen Residence, 16108 7 lace West J-767 Edmonds, Washington July 12, 2001 Page 2 design, we recommend that the earth pressure diagram used for the structural design of the wall be submitted for review. Analyses of the western portion of the property have not been submitted. Utilities and other elements subject to possible damage will be installed in this area. We recommend that the engineer provide mitigation recommendations for potential instability in the western portion of the site. The landslide probability both during and after construction should be restated based on the supplemental data and analyses. Temporary excavation within the west side of the property for construction of the basement foundations should be analyzed, and excavation criteria to minimize instability risk should be provided in the soils report and on the plans. We appreciate the opportunity to have been of service on this project and would be pleased to discuss the contents of this report or other aspects of this project with you at your convenience. Respectfully submitted, ZIPPER ZEMAN ASSOCIA IC John E. Zipper, P.E. President (EXPIRES 1 124 l 0 18905-33rd Avenue West, Suite 117 Lynnwood, Washington 98036 (425) 771 - 3304 LO DODDS RECEIVED GeoSciences Inc. MAR 1 6 2001 Post Office Box 2385 STREET FILE Kirkland, WA 98083 BUILDING DEPT. Tel: 425.827.1.084 Fax: 425.828.9443 Chien Dinh Nguyen Job Number 8042 18311 - 713t Avenue West October 30, 2000 Lynnwood, WA 98037 Subject: Addendum No. 5 STREET FILE- Edmonds, 160XX 75th Place West Washington Dear Mr. Chien: In accordance with your request, we have completed an additional test boring and engineering analysis of the slope above the proposed retaining wall. The test boring data is enclosed. In addition, significant laboratory testing was completed to verify accuracy of the field soil classifications and designations. Computer stability analysis of the slope above (east of) your property was completed. We assumed for this analysis that the standing groundwater table was at six feet below grades at the location of Test Boring #3 as that was the highest depth at which we observed oxidation in the soils. Further, we observed a zone of heavy fracturing at about 22.5 feet below existing grades in Test Boring #3. Our analysis assumed a failure surface which included three critical points. First, the crack in the roadway was assumed to be on the failure scarp. Second, the fractured zone noted in Test Boring #3 was assumed to be in the failure circle. And finally, it was assumed the failure surface would also be somewhere near the toe of the existing slope. Our analysis parameters were selected for the specific failure circle and are not meant to be general parameters for the soil layers. First, we performed a parameteric study of the input parameters until we got a static Factor of Safety (F.S.) of 1.06. We felt, this was within the ballpark for the observed conditions. Then we added a horizontal and vertical load to simulate earthquake loading in a moderate earthquake. A horizontal coefficient of 0.2g and a vertical coefficient of 0.1 g was deemed adequate for this site. This resulted in a dynamic F.S. of 0.57, or failure. • • CHIEN ADDENDUM # 5 October 30, 2000 Job Number 8042 Page 2 Analysis was then completed of the driving and resisting forces in the dynamic (earthquake) situation. This resulted in an unresolved driving force of 20113 pounds for the slice being considered during an earthquake. Using , the 65 pounds per cubic foot designated in our Addendum 02 for the height and depth specified resulted .in modeled active load of 28,283 pounds for the earthquake condition. It is therefore our opinion that the geotechnical engineering parameters which have been previously specified for this wall are adequate and appropriate. Please contact the undersigned if there are any questions. Thank you, DODDS Geosciences Inc. ppnP... a WA < f Mark K. Dodds, P.E. ` Hole No. 8-3 • PROJECT: T5th Place West WATE DRILLED: 09/29/00 DRILL RIG: Trailer Mounted Rig LOGGED BY: MKD ' HOLE DIA: 8 in. SAMPLER: SPT INITIAL WATER DEPTH: 16.0 ft. HOLE ELEV: 1 71.0 MSL FINAL WATER DEPTH: 18.0 ft. TOTAL DEPTH: 28.0 ft. w DESCRIPTION SOIL GRAPHIC = BLOWS REMARKS TYPE LOG C /FT. N Brown Silty Sand with some Gravel, moist, loose. SM Gray -brown with oxidation Clayey Silty Sand with some Gravel, moist, SM loose. - rgM Brown Silty Clay with lenses and layers of Silty Sand and Silt, wet, CL soft to firm. Groundwater table at 18.0 feet during drilling. . Gray Silty Clay, highly plastic, wet to saturated, stiff. CH Small lens (I.5" thick) of heavy fracturing. cotcom or test voting at zo.0 feet. urounowater taoie near iti.0 reet during drilling. 0 2 4 6 8 10 12 14 16 18 20 22 26 28 5 7 2 6 8 5 8 8 21 23 Moisture Content = 11.9% Moisture Content = 14.8% Moisture Content = 28.5% Moisture lContent = 31.7% Moisture Content = 34.4% Moisture Content = 39.6% Moisture Content = 35.1% Moisture Content = 34.6% Moisture Content = 31.7% Moisture Content = 30.0% DODDS GEOSCIENCES INC.. PA15E 1 OF 1 BORING LOG SB-SLOPE Simplified Bishop Slope Stability Analysis PROJECT: LOCATION: 75th Place West, Edmonds,, Washington FILE: CHIEN COMPLETE SLOPE CROSS SECTION CIRCLE X Y RADIUS FS 1 231.7 111.4 GG.9 0.58 360 320 280 240 Z O H Q 200 w J W 160 126 Be 40 0 -40 40 80 120 160 200 240 280 320 360 HORIZONTAL DISTANCE DODDS GEOSCIENCES INC. DODDS GEOSCIENCES INC. r a.►� Ica B-2 y ■ ® ■®m ■ a emm City of Edmonds Permit No:-�' RIGIJT=CPF-WAY CONSTRUCTION PERMIT Issue Date: q— A a — A. Address or Vibinity of Constructtiion: Wrj2) y 7 5' Y la" WL+ ` K1-xAot zAaU_ B.,Type of Work �(be specific): Llr� t�1�-�1 CRQ �t" 0., 10 tr'*Ke am in :.roar, { . ;dc i A:.IS4 '` rII� Q C. Contractor: k\o)'A �t� s�- �c,'.Vr,1Q Contac � ,�� �ri� G"1 , ► • �. Mailing Address: I la -7n L i'" Adtr Wes" ltbO Phonef 1�1�i:-S.-^� 7 i - D[06 State License #: NI Ar ° Liability Insurance: Bond: $ D. Building Permit # (if applicable): Side Sewer Permit # (if applicable): i E. ❑ Commercial ❑�'Subdivision El City Project ❑ EUC (PUD, VA�RIZON, PS�E,,�T& T, OVWD) ❑ Multi -Family Single Family ❑ Other INSPECTOR: F. PAVEMENT CUT: ❑ YES 910 G. SIZE OF CUT X CONCRETE CUT: ❑ YES 10 / _lc°-, INDEMNITY: Applicant understands by hislher signature to this application helshe holds the City of Edmonds' harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen; . that may be made against the City of Edmonds or any of its. departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit.. r THE CONTRACTOR IS RESPONSIBLE FOR WORKMANSHIP AND MATERIALS �OR A PERIOD OF ONE YEAR FOLLOWING THE FINAL" INAPECTION AND ACCEPTANCE OF THE WORK. ESTIMATED RESTORATION FEES WILL BE HELD UNTIL THE FINAL STREET PATCH IS COMPLETED BYCITY FORCES, AT WHICH TIME A DEBIT OR CREDIT WILL BE PROCESSED FOR ISSUANCE TO THE APPLICANT. ♦ Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. �. Restoration is to be in accordance with City codes. All'street-cut trench work shall be patched with asphalt or City - approved material prior to the end of the workday — NO EXCEPTIONS. ♦ Three sets of construction drawings of proposed work are required with the permit application. QIQ(41 800-424-5555) PRIOR TO BEGINNING WORK I HAVE READ THE ABOVE STATEMENTS AND UNVERSTAND THE PERMIT REQUIREMENTS AND ACKNOWLEDGE THAT I MUST MAKE THE PINK COPY OF THE PERMIT AVAILABLE ON SITE AT ALL TIMES FOR INSPECTIONS Signature: Date: (Contractor or Agent) FOR CITY USE -ONLY Approved by:i'°'' Right-of-way Fee: 7` Time Authorized: Void'After14P? E!o / Disruption Fee/Fund 111: Special Conditions: Restoration Fee:'. G t ��;aiui ' .��'`�` Total Fee: 1?�a LYTVA WC-eot.- 710p) 1-0r1V i Hi T7'ii,)oq Receipt No: -20493 A tea, TAw_6. - Issued by:' UPON COMPLETION OF PERMITTED. -WORK, AN ENGINEERING FINAL INSPECTION IS REQUIRED.PER CHAPTER 18.00 OF THE-EDMONDS . COMMUNITY DEVELOPMENT CODE (Phone 425-771-0220, Ext.1326) FINAL APPROVAL OFPERMITTED WORK. _OASSin�pu t Pcrmrt �x iD �� DATE• /oh -del Inspector's Signature J (,ofliKS For•inspection reauirements see Engineering Inspection Information handout. NO WORK SHALL BEGIN PRIOR TO PERMIT ISSl1ANCE August 30, 2002 HNVA Project No. 2002-099-21 City of Edmonds Development Services, Engineering Division 121 5°i Avenue North Edmonds, Washington 98020 Subject: Street Use Permit Application Nguyen Residence at 16108 75th Place «lest Edmonds (AfeadoNvdale), R'ashington Attention: Darrell Smith, P.E., Traffic Engineer ulu1 HWAGEOSCIENCES INC. 19730-64TH AVE. W., SUITE 200 LYNNWOOD,WA 98036-5957 TEL.425-774-0106 FAX.425-774-2714 www.hwageosciences.com The enclosed Right -of -Way Construction Permit application is submitted in preparation for a geotechrucal boring program at the above -referenced property. The purpose of our work is to explore and evaluate subsurface conditions on the Nguyen property and the adjacent slope to the east. We propose to drill one test boring along the west shoulder of 75"' Place West, within City right -of --way. Two other test borings will be drilled within the Nguyen property. The borings will be drilled by a drilling subcontractor under full-time supervision of an HWA geotechrvcal engineer. The attached site map shoes the approximate proposed location of the boring along 75"' Place West. The actual location may be adjusted as required to avoid existing utilities. Because the proposed boring is located in the -ravel shoulder and off of the pavement, we anticipate minimal impacts to traffic, i.e., no lane closures are necessary. Waming signs and cones will be used in accordance with the attached "Typical Application 6" traffic control plan (for shoulder work with minor encroachment). A 23/<-inch diameter, ABS slope inclinometer casing will be installed in the borehole. The annulus between the casing and the borehole will be grouted, and the top of the casino, will be covered/protected with a flush -mount, locking steel monument cover, set in concrete. All soil cuttings generated during the drillina process will be placed in steel drums and removed. There will be minimal impacts to the site. We estimated it will take approximately three to four hours to complete the boring. . If you have any questions or require additional information, please contact the undersigned at your convenience. O ° O Sincerely, HWA GEOSCIENCES INC. -a 0, cj"' Erik O. Andersen, P.E. Project Manager Attachnimts: Right -of -Way Construction Permit Application and S75.00 processing fee. Site Plan — Proposed Boring Location Traffic Control Plan TA-6 GEOLOGY GEOENVIRONMENTAL SERVICES HY.DROGEOLOGY GEOTECHNICAL ENGINEERING TESTING & INSPECTION I Ir PERMIT #: CP-- Z4 t DATE APPLICATION RECEIVED: 2— WORK ADDRESS: 1/0600 -74`' 1q- kd CONTRACTOR: INA- RECEWED DATE TO PUBLIC WORKS FOR REVIEW.- SEP V 2 2007 PUBLIC GYORKS DEPI STREET DIVISIO(,-`f Date: -10 -01- Signature of Approval Comments:. WATER/SEWER: Date: Signature of Approval Comments: PW DIRECTOR: Date: -10, 6,)- Signature of Approval RECEIVED Comments: SFP 112002 REMINDER: Comments made on any of the attachments need to be done with a red pen on ALL 3 COPIES. Date and initial all changes or comments. PLEASE RETURN TO R:\engr\forms\ROW permit routing December 2000 Page 6H-17 Figure 6H-6. Shoulder Work with Minor Encroachment (TA-6) �v � �1t1��3' �•A � _ .h A MMNote: See Tables 6H-2 and 61-1-3 - for the meaning of the symbols and/or letter Pet KZ;codes used in this figure. `="fit tea"- 3 j�y IQ� ; Truck -Mounted 4 Attenuator (aoional) a: E ,V a rz' Au rr�•,; 5 i or 17 Typical Application 6 Sect. 6H.01 I O •� O O O A m n O mv 10 7— 070 a z m { 1 0 0 go -k —n 3n m 0 u � °O mo .. „w p n K = n o � r n m < N tNn m a o � a O O O w N O♦ ^ 01 0 { 0 a O O y S w pp9+� O N VI m .O O m v O N c D T Z � � � ®� m %� r s Z �P 2 Z 110 O g 8 40 7C � M r P N Z SP P a O a w 0- so H N 4 { w O ♦ f 7 ,I O ^{3 B 7 c �l m,°t u m 017 100 a(7 O'm 7c -• so O uV--60 NA o7 0m 0u0 OA Nm o�o n �o c —mom u. to �. Q. CLO uu v0 niO 3° tin A 0 7 r, .aim m e 3m ,o < u w O 07 { { 0 0 3 7 o a ^m �o a 0 nAOQy 0' { {v �+c 0 0{{ 7 nOi O 0m Nn o9-in n O w u0'<, O ex m C 7 -m n 0 { m 7^ { 41 Cl i — :O n ^ a0 ^Omn 0 m u (7me m nl MO N 0 7 M a ° miM w c -L4-1 { - a a pao < m n:3I " o ' a 7 c a ='O>> E a 0 . 7 3 m 0 �m Q. va c N • f n or y m t 050 C 3 O {m { n J [O 7 O 76 u to E O i° o v + O f o �< 0 ou O � n Lm u . 00 G9 0 u o .06 + a u 0 n O 10 { w —0 —� f 0 v0 { n. 0 m M M �� 0 a'I to c o n ,c 7 Z_ :,� 29 _j zz u W 0 w TO N\0 ULL 0 UO 5) w W>- 0- om LLJ En �z Cf) Ix WZ w 0 W XX w z _�c W Cf) U-) 0 LL w w W Z W -,h 00 ?o so— tosz BO --t W, co CD COLD— Lrl N Lu 4) � fr 0 —1 0 a_ _Z H loc. 1890 CITY OF EDMONDS . BARBARAFAHEY 121 5TH AVENUE NORTH • EDMONDS. WA 98M • (425) 771-OM • FAX (425) 771-0221 MAYOR COMMUNITY SERVICES DEPARTMENT Public Works • Planning/Building • Parks and Recreation • Engineering • Wastewater Treatment Plant May 21, 1998 Chien Dinh Nguyen 18311 71 $r Ave W Lynnwood, WA 98037 CHHON COPY Faxed RE: ROAD STABILITY ON 75TH PL W ADJACENT TO PARCEL 51310590060001 (LOT3) MCCORIKLE SHORT PLAT S-23-90 Dear Mr. Nguyen, We received your letter dated May 10, 1998 and recognize the portion of the Meadowdale Landslide Hazard area described in your letter. Slope failures have occurred at the area identified in your pictures. A major slide occurred in 1956, and the area continues to subside. Approximately four years ago, the Public Works Department repaired that portion of 75`h Place W by removing the pavement, compacting the soil, and paving that section to provide a smooth driving surface. Soil movement and instability is an ever-present problem in the Meadowdale area. The City will continue to do interim repairs when required. If you have any more questions, please call Don Fiene at 425-771-0220, ext 323. Sincerely?, James C. Walker, P.E. City Engineer Cc: Jeannine Graf *.Incorporated August 11, 1890 • Sister Cities International —, Hekinan, Japan Critical Areas Checklistfs- --------- g ------------------ Site Information oils/topography/hydrology/ve etation) 1. Site Address/sLocatio /(o!� g &re t57'-- 2. Property Tax Account Number: 5g 1, ti D Dr7 3. Approximate Site Size (acres or square feet): 19 20 14S. iff— 4. Is this site currently developed? _ yes; __�/no. If yes; how is site developed? 1 /29 XJA,�/W 5. Describe the general site topography. Check all that apply. ►--� Flat: less than 5-feet elevation change over entire site. __LZRolling: slopes on site generally less than 15 °% (a vertical rise of 10-feet over a horizontal distance of 66-feet). t/ Hilly: slopes present on site of more than 15% and less than 30% (a vertical rise of 10-feet over a horizontal distance of 33 to 66-feet). Steep: grades of greater than 30°% present on site (a vertical rise of 10-feet over a horizontal distance of less than 33-feet). Other (please describe): 6. Site contains areas of year-round standing water: --F ; Approx. Depth: 7. Site contains areas of seasonal standing water: �(� ; Approx. Depth. What season(s) of the year? 8. Site is in the floodway-4ZO_ floodplain_d� of a water course. 9. Site contains a creek or an area where water flows across the grounds surface? Flows are year-round? _ Flows are seasonal? --, 0 (What time of year? ). 10. Site is primarily: forested ; meadow V" ; shrubs ; mixed urban landscaped (lawn,shrubs etc) 11. Obvious wetland is present on site: f �4 ForGi Staff _IJse.Ori1 ZC� r �r y 1. Site is Zoned? Q I -SCS mapped soil :type(s)? (o� '�.. r if . !ii:., �`j 7`) r 3; Wetland inventory or C.A.map indicates wet] nd pres on site? � 4: Critical Areas inventory or. C.A.. map indicates Critical Area 5. Site within designated earth'suhsidence landslide haiard areal Q?,,, 6: Site designated on,the.Environmentally:.Sensitive Areas Map? ( ?,` DETERMINATION Reviewe ^ca chkdoc; ;CONDITIONPiL'WAIVER D e I a 0 ,� CA FILE NO. Critical Areas Checklist ------------------- Site Information (soils/topography/hydrology/vegetation) 1. Site Address/ Location: L�Zr5 ESQ ; 11-- 2. Property Tax Account Number: 0n 4 ©6(�) 3. Approximate Site Size (acres or square feet): /--'-3 20` S. if 4. Is this site currently developed? _ yes; _�/no. If yes; how is site developed? f/%7g X,4,�7,W SI& ,� ILV /P6_S10-r_ 5. Describe the general site topography. Check all that apply. ►� Flat: less than 5-feet elevation change over entire site. �olling: slopes on site generally less than 15% (a vertical rise of 10-feet over a horizontal distance of 66-feet). I/Hilly: slopes present on site of more than 15% and less than 30% ( a vertical rise of 10-feet over a horizontal distance of 33 to 66-feet). Steep: grades of greater than 30% present on site (a vertical rise of 10-feet over a horizontal distance of less than 33-feet). Other (please describe): 6. Site contains areas of year-round standing water: - ; Approx. Depth: 7. Site contains areas of seasonal standing water: �r� ; Approx. Depth: What season(s) of the year? 8. Site is in the floodway— "/— floodplain_of a water course. 9. Site contains a creek or an area where water flows across the grounds surface? Flows are year-round? _ Flows are seasonal? AhQ (What time of year? ). 10. Site is primarily: forested ; meadow ✓ ; shrubs ; mixed urban landscaped (lawn,shrubs etc) 11. Obvious wetland is present on site: -------- _----------------==---=---- - ----- For City St af .Use. Qnly------------------- ------------- -- 1... Site is Zoned? K� .`` .. U 2. -SCS mapped soil:type(s)7 .` , f �lVF10, o . N''4t' c,;: -, Q t S 3; . Wetland inventory or C.A. map: indicates wetland prese40ri site.?��: 4: Critical Areas inventory or. C.A. map indicates Critical Area on site: 5: Site within designated earth subsidence landslide hazard area?. 6. Site designated on:the Environmentally:.Sensitive Areas Map? l p i Inop- -A DETERMINATION Reviewed 1 ^ca_chk.doc; Rev RECEIVED City of Edmonds OCT o , 1998 CRITICAL AREAS CHECKLIST The Critical Areas Checklist contained on this form is to be filled out by any person preparing a Development Permit Application for the City of Edmonds prior to his/her submittal of a development permit to the City. The purpose of the Checklist is to enable City staff to determine whether any potential Critical Areas are, or may be, present on the subject property. The information needed to complete the Checklist should be easily available from observations of the site or data available at City Hall (Critical Areas inventories, maps, or soil surveys). An applicant, or his/her representative, must fill out the checklist, sign and date it, and submit it to the City. The City will review the checklist, make a precursory site visit, and make a determination of the subsequent steps necessary to complete a development permit application. Please submit a vicinity map along with the signed copy of this form to assist City staff in finding and locating the specific piece of property described on this form. In addition, the applicant shall include other pertinent information (e.g., site plan, topography map, etc.) or studies in conjunction with this Checklist to assist staff in completing their preliminary assessment of the site I have completed the attached Critical Areas Checklist and attest that the answers provided are factual, to the best of my knowledge (fill out the appropriate column below). Owner/Applicant: Name /Y-3/1 7/,5�'- Avg - Street Address ZVAZLAZMQu/r Ci y �../^State Zip ('-� / / �✓ J / ��� Telephone; Sigriat rue o ?--/ 7, Date c: receptionlj an alcacl. doc Applicant Representative: Name ,&4M,(4"C,�41� 41 Street Address �._.IAnonq _ 10 . City State Date (over) CITY OF EDMONDS BARBARA FAHEY MAYOR 121 5TH AVENUE NORTH - EDMONDS, WA 98020 - (425) 771-0220 - FAX (425) 771-0221 COMMUNITY SERVICES DEPARTMENT Public Works * Planning/Building * Parks and Recreation - Engineering a Wastewater Treatment Plant October 12, 1998 Chien Dinh Nguyen 18311 71 st Ave. West Lynnwood, WA 98037 Subject: Determination regarding Critical Areas Checklist # 98-245 Dear Applicant: Enclosed please find a copy of the Critical Areas Checklist you submitted. The "DETERMINATION" reached by the City is located on the reverse side of the form (bottom of page). It is very important for you to retain a copy of this Critical Areas Checklist "DETERMINATION" for your records. _.. _.. _... ........ IMPORTANT INFORMATION TO BE NOTED: PLEASE EXAMINE THIS" DETERMINATION" FOR ADDITIONAL REQUIREMENTS, YOU MAY NEED TO SUBMIT ADDITIONAL INFORMATION SUCH AS AN ENVIRONMENTAL CHECKLIST OR CRITICAL AREAS STUDY. The 'DETERMINATION' for the Critical Areas Checklist you submitted is a site -specific determination not a project -specific determination. You must submit a copy of the CRITICAL AREAS CHECKLIST and DETERMINATION WITH ALL .4111111111 PERMIT APPLICATIONS or YOUR APPLICATION WILL NOT BE PROCESSED. Permit applications include the following: Building Permits Conditional Use Permits Subdivisions Variances Applications to the ADB* Land Use Applications Any other development permit applications. Eric: Critical Areas Determination * Architectural Design Board Thank you, Sharla Graham Planning Secretary C: ReceptlonUana\CRLTR.doc 0 Incorporated August 11, 1890 0 Sister Cities International — Hekinan, Japan �j . City of Edmonds PermitNo: RIGHT -'OF -WAY CONSTRUCTION PERMIT Issue Date: 1 (310a A. Address or Vicinity of Construction: l _ /,.a NCR— B. Type of Work (be specific): 1J a c O N e- ` * L �' & C. Contractor: D D N b S R _5Ui'JC ' Contact: X4.4 k /.)o d d Mailing Address: O 1 2� $S (L' ��1 Phoneo State License #: A/A Liability Insurance: Bond: $ D. Building Permit # (if applicable): Side Sewer Permit # (if applicable): E. ❑ Commercial ❑ Subdivision ❑ CityProject ❑ EUC (PUD, GTE, PSE, CHAMBERS, OVWD) ❑ Multi -Family Single Family ❑ Other INSPECTOR- lye i F. PAVEMENT: ❑ YES aNO G: -..,,SIZE OF CUT AM X H. Charge: $ CONCRETE CUT: ❑ YES ❑ NO APPLICANTTO READ 1'.: SIGN IDEMNITY: Applicant understands by his/her signature to this application helshe holds the City of Edmonds harmless from injuries, damages or claims -of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorneyfees by reason ofgranting this permit. THE CONTRACTOR IS RESPONSIBLE FOR WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FOLLOWING THE FINAL INSPECTION AND ACCEPTANCE OF THE WORK. ESTIMATED RESTORATION FEES WILL BE HELD UNTIL THE FINAL STREET PATCH IS COMPLETED BY CITY FORCES, AT WHICH TIME A DEBIT OR CREDIT WILL BE PROCESSED FOR ISSUANCE TO THE APPLICANT. ♦ Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296455-305 and must have certification verifying completion, of the required training in their possession. - ♦ Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end.of the workday — NO EXCEPTIONS. ♦ Three sets of construction drawings of proposed work are required with the permit application. I HAVE READ THE ABOVE STATEMENTS AND UNDERSTAND THE PERMIT REQUIREMENTS AND ACKNOWLEDGE THAT I MUST MAKE THE PINK COPY OF THE PERMIT AVAILABLE ON SITE AT ALL TIMES/FOR) INSPECTIONS Signature: / ~� �.►^S"� & -5 Date: 9 °p CALL DIAL -A -DIG (1-800424-5555) PRIOR TO BEGINNING WORK Approved by:.. Time Authorized': Void AfteiC ..Special t o ditions: �c.�Q GJ L V1NLY Right-of-way Fee: Disruption Fee/Fund 111' Restoration Fee: Total Fee-., Issued UPON COMPLETION OF PERMITTED WORK, AN ENGINEERING FINAL INSPECTION IS REQUIRED PER CHAPTER 18.00 OF THE EDMONDS COMMUNITY DEVELOPMENT CODE. FINAL APPROVAL OF PERMITTED WORK. INSPECTOR'S SIGNATURE DATE: For inspection requirements see Engineering Information Handout. NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE; �e . DATE RECAA he ©O I PERMIT EXPIRES Al„i ` ZONE RS —= PERMIT CITY OF EDMONDS NUMBER NUMBER CONSTRUCTION PERMIT APPLICATION ,IDADDD RESS d 1�1 ? x pL, sulrEtaPT - � J ''. OWNER NAME/NAME OF BUSINESS PLAT N/A��M'jE/ff$�V,BI,DIVIcSION N0. LOT NO. ID NO � . � �. y vW�"ti"'E' ,% -9J MAILING ADDRESS 'V/ �( L'j '�•T % / / ZD'f i 2S Qp 1� j/✓P j !v �' vl/ CFFEE$ PUBLIC RIGHT OF WAY PER OF ICIAL ST ET G CITY ZIP TELEPHONE �d EXISTING. PROP D 11, P.4uU.d ewaB Requasd L )t /J, �•.yy� LfiC%v1 �•{ J /Y/gt�G�.L• y(iL./v/ A��� � 4c � �� `'�P-Y EOUIRED DEDICAT N T wiring `eq"d wiring required NAME ETER IZEII SIZE FIXTURES P V R OUIRED jr: YES NO Q V A IDREE/SAS ./{.y�� RKS R/CONTRACTOR SIBL R EROSION CONTROUDRAINAGE z i aJ wv i {; CI P TELEPHONE 6 �� • �� / NAME f' ENGINEERING . -: REVIEWED/DATE M ADDRESS .. ., IRS REVIEWED BY DATE w CITY ZIP I TIV YARIAN - 'C '�- H LINE' � DBs INSPECTION REO'D BOND POSTED STATE LICENSE NUM EXP NOAEE E ED BVa -- (,YES ONO EPA R , SION'AREA HEIGHT PROPERTY TAX ACCOU RCELNO. - ETE-' E ALLOWED PROPOSED �� ALLOWED PROPOSED 0 NEW RESIDENTIAL:.: -' C - COVERAGE ,REQUIRED ED PROPOSED FRONT SETBACK$(FT.) SIDE REAR PROPOSED SETBACKS (FT) FRONT--IJR SIDE REAR u ❑ AUDITION C LI NO❑ N E `'.. PARKING. LOTAREA IPLANNINdREVIEWEDSY�.DATE g ❑ REMODEL - ❑ - APARTME SIG REO'D PROVIDED .. , FENC — ❑ REPAIR ❑ ( _X FT). REMARKS ❑ DEMOLISH ❑ TANK OTHER - RETAINING WALL ❑ RENEWAL OARRAGGE ❑ _ Zp a (TYPE OF USE, BUSINESS OR ACTT PLAIN:- CHEM.TYPE OF ON C OCCUPANT/']' CUP cNUMBER OF NUMBER OF OWELUNG '. CRITICALII /� AREAS %J� ���1 SPECIAL INSPECTOR AREA OCCUPANT T' o STORIES UNITS. NUMBER .J REOVIRED ❑-,yEs LOAD � r I - DESCRIBE WORK TO BE DONE / � :�>..: REMARK_ PROGRESS'INSPECTIONS PER''UBC 108JFINAL INSPECTION REO'D y GCD m .�cq4 V.vv riv j4 1 VALUATION FEE V. CHECK FEE H V CE GLAZING % Jf/?.n' t ?Iy'C/ LOT SLOPE % canBUILDING y5� — PLAN CHECK may. VESTED DATE PLUMBING .- ­10 MECHANICAL THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO - t: BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC GRADING/FILL +� Z DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. STATE SURCHARGE w PERMIT APPLICATION: 180 DAYS PERMIT LIMIT: 1 YEAR • PROVIDED WORK IS STARTED WITHIN 180 DAYS ENO. REVIEW FEES 5C% SEE BACK OF PINK PERMIT FOR MORE INFORMATION -APPLICANT, ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESORS ENO. INSPECTION FEE IN INTEREST. AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE CITY OF LANDSCAPING 2 EDMONDS, WASH11 TON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM ANY AND INSPECTION FEE a ALLCLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLYOR INDIRECTLY RECEIPT = FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE PLAN CHECK DEPOSIT p 4 j DEEMED TO MODIFY, WAIVE OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE 0 NOR LIMIT IN ANYWAY THE CITY'S ABILITY TO ENFORCE ANY ORDINANCE PROVISION.' RECEIPT TOTAL AMOUNT DUE i HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THAT THE INFORMATION APPLICATION APPROVAL GIVEN IS CORRECT, AND THAT I AM THE OWNER, OR THE DULY AUTHORIZED AGENT OF THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- CALL This application is not a permit until signed by the TION; AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED Building 081cial or his/her Deputy: and Fees are paid, and IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION receipt Is acknowledged in apace provided. WORKMEN'S COMPENSATION INSURANCE AND RCW 1827. OFFICIALS SIGNATURE DATE OWNE SIGNAT ORAGENT) DATE SIGNED (425) - m 771,0220 RELEASED BY GATE ATTENTION EXT 333 IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL 771-0221 A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI- ORIGINAL -FILE • YELLOW.INSPECTOR CATE OF OCCUPANCY HAS BEEN GRANTED. UBC SECTION 109 FAX PINK - OWNER • GOLD - ASSESSOR s/98 LS J U w LO U - 3 3 Z N a ❑ z W Ludim m �❑ J 5 SS i `. W 2' ❑ m o� Z LLas N � � a! U � � w mz O � o m U4o W z ScD S Z pp z W UCuu]� � w0 KO J � �-o m I I � y annos I I d - iry i %bH 0'SZ 70-1--c-) 16le-,e �5 /,,/- t-v