18620 88 AVE W-SITE PLAN (2).pdfGENERAL NOTES GENERAL: PROJECT ADDRESS ALL CONSTRUCTION SHALL CONFORM TO THE <_'Y-s INTERNATIONAL BUILDING CODE t THE ,, w�iNTERNATIONAL RESIDENTIAL CODE (IRLi Aa AMENDED BY THE STATE OF wAz:�HINGTON AND BE IN ACCORDANCE WITH WASHINGTON STATE LAWS, REGULATIONS AND VARIOUS CODES IMPOSED BY LOCAL AUTHORITIES. ALL CONSTRUCTION SHALL ALSO CONFORM TO THE,/v <•-WASHINGTON STATE ENERGY CODE, THE - INTERNATIONAL FIRE CODE, IHE 2014 NATIONAL ELECTRIC CODE, THEj- INTERNATIONAL MECHANICAL CODE, THE 7_,,,6-NTERNATIONAL NATION,4 . uEL AND GAS CODE AND THE 'NIFOR'1 PLUMBING ... c. DO NOT SCALE DRAWINGS OR DETAILS - USE GIVEN DIMENSIONS. CHECK D -S FOR LOCATION OF ALL ITEMS NOT DIMENSIONED ON THE PLANS. DIMENSIONS ON T"E CLANS ARE TO FRAMING OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE. DOOR AND CASED OPENINGS WITHOUT DIMENSIONS ARE TO BE 4" FROM FACE OF ADJACENT WALL OR CENTERED BETWEEN WALLS, UNLESS NOTED OTHERWISE. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION Cr THE WORK THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. CONTRACTORS RESPONSIBILITY: CONTRACTOR TO VERIFY ALL DIMENSIONS AND STRUCTURAL MEMBER SIZES PRIOR TO CONSTRUCTION. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK ALL STRUCTURAL SYSTEMS SUCH AS WOOD TRUSSES WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPP_IER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER CONTRACTOR TO COORDINATE FRAMING LAYOUT WITH ELECTRICAL AND ME:�--".0 PLAN. FOUNDATION DESIGN 15 BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 2,000 PSF. ALL FOOTINGS SHALL BE CAST ON UNDISTURBED FIRM NATURAL SOIL OR COMPACTED 501L OF 2,000 PSF BEARING CAPACITY AT LEAST I'-&" BELOW LOWEST ADJACENT GRADE, FREE OF ORGANIC MATERIALS. FOOTING EXCAVATION SHALL BE FREE OF LOOSE SOILS, DEBRIS, AND FREE WATER AT ALL TIMES. CLEARING AND GRADING (T.E.S.C. MEASURES ALL CLEARING AND GRADING MUST BE IN ACCORDANCE WITH LOCAL JURISDICTION CLEARING AND GRADING ER05ION CONTROL STANDARDS, DEVELOPMENT STANDARDS LAND USE CODE, INTERNATIONAL RESIDENTIAL CODE, PERMIT CONDITIONS, AND ALL OTHER APPLICABLE CODES, ORDINANCES AND STANDARDS. THE DESIGN ELEMENTS WITH THESE PLANS HAVE BEEN REVIEWED TO THESE REQUIREMENTS. ANY VARIANCE FROM THE ADOPTED EROSION CONTROL STANDARDS IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE LOCAL JURISDICTION PRIOR TO CONSTRUCTION. A COPY OF THE APPROVED PLANS MUST BE ON -SITE WHENEVER CONSTRUCTION IS IN PROGRESS- THE APPLICANT IS RESPONSIBLE FOR OBTAINING ANY OTHER REQUIRED OR RELATED PERMITS PRIOR TO BEGINNING CONSTRUCTION. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS AND TO DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN WHICH MAY BE EFFECTED BY THE WORK FINAL SITE DRAINAGE MUST DIRECT DRAINAGE AWAY FROM ALL BUILDING STRUCTURES AT A MINIMUM OF 6" WITHIN THE FIRST 10', PER IRC R4013. CRAWL SPACE: UNDER -FLOOR AREAS SHALL BE VENTILATED BY AN APPROVED MECHANICAL MEANS OR BY OPENINGS IN EXTERIOR FOUNDATION WALLS. SUCH OPENINGS SHALL HAVE A NET AREA OF NOT LESS THAN 1 SQ, FT, FOR EACH 150 SQ. FT. OF UNDER -FLOOR AREA. ONE OPENING SHALL BE WITHIN Y OF EACH CORNER OF THE BUILDING. IRC R4082. CRAWL SPACE, UNOBSTRUCTED ACCESS, MINIMUM 18" x 24". IRC R406.4. PROVIDE 18" MINIMUM CRAWL SPACE UNDER WOOD JOIST AND 12" MINIMUM CRAWL SPACE UNDER WOOD GIRDERS. IRC R311.1. A GROUND COVER VAPOR BARRIER OF MIN. 6 MIL. (0.006") POLYETHYLENE (OR EQUIVALENT) SHALL BE INSTALLED IN ALL CRAWL SPACES, JOINTS LAPPED 12", EXTEND UP FOUNDATION WALL AND SECURE TO SILL PLATE WHEREVER PRACTICAL. ALL WOOD IN CONTACT WITH CONCRETE, CMU OR WITHIN 8" OF SOILS SHALL BE PRESSURE TREATED WOOD IN COMPLIANCE WITH IRC R311.1. FACTORY -BUILT FIREPLACES AND CHIMNEYS SHALL BE LISTED AND INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS, IRC R1004.1 AND TESTED IN ACCORDANCE WITH UL 121. MASONRY FIREPLACES, BARBECUES, SMOKE CHAMBERS AND FIREPLACE CHIMNEYS SHALL BE CONSTRUCTED OF MASONRY OR REINFORCED CONCRETE. FOUNDATIONS SHALL BE MIN, 12" THICK AND EXTEND MIN. 6" BEYOND MASONRY. FIREBOX WALLS MIN. 10" THICK EXCEPT MIN. 8" THICK WHERE A FIREBRICK LINING IS USED. COMBUSTIBLE MATERIALS SHALL NOT BE PLACED WITHIN 2 INCHES OF FIREPLACE, SMOKE CHAMBER OR CHIMNEY WALLS. COMBUSTIBLE MATERIAL SHALL NOT BE PLACED WITHIN 6" OF THE FIREPLACE OPENING. MIN. 4" THICK NON-COMBUSTIBLE HEARTH EXTENDING 16" IN FRONT AND 8" TO THE SIDE OF THE FIREPLACE OPENING. COMBUSTIBLE MATERIAL WITHIN 12" OF THE FIREPLACE OPENING SHALL NOT PROJECT MORE THAN 1/6" FOR EACH I" DISTANCE FROM SUCH OPENING. IRC R1001-R1003. CEILING HEIGHTS HABITABLE SPACE SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 1'-0". NOT MORE THAN 50% OF REQUIRED FLOOR AREA OF A SPACE IS PERMITTED TO HAVE A SLOPED CEILING LESS THAN 1'-0" IN HEIGHT WITH NO PORTION LOWER THAN 5'-0". BATHROOM SHALL HAVE A MIN CEILING HEIGHT OF 6'-8" OVER THE FIXTURE AND ITS FRONT CLEARANCE AREA. IRC R305. ROOFING: APPLY ROOFING IN ACCORDANCE WITH IRC R905. BALCONIES, LANDINGS, EXTERIOR STAIRWAYS, OCCUPIED ROOFS AND SIMILAR SURFACES EXPOSED TO THE WEATHER AND SEALED UNDERNEATH SHALL BE WATERPROOFED AND SLOPED A MINIMUM OF 1/4" PER 12" (2% SLOPE) FOR DRAINAGE. I I 34� 3 �$ 3421 ` 346/ \ J ` FIELD MEASUREMENT 9/FACE OVERHANG I I � PROPERTY LINE 1 I S 89°�4'13" E 242.m2' � v � � �- - m EXST DECK("" COO) EDGE T i60F ® ~REt OVED - FIELD MEASUREMENT TO EDGE OF ASPHALT I� w yDGE EXST CONC. EXST SHED i .- 3�.1 100 SF I -__- A. EXST I 1 I NEW DECK �INe�FILL j ASPHALT i \ DRIVE CONIC. AL410-1 EXST HOME IL I I 1,121 6F ENTRY PORCH E ST CONIC/ '' z I PATIO REMOVED r 25' m" I ' +351 ' I ROOF O I�AAT1Cz r�Prra)` 25 -0 ��N lie e- ` i u / SETBACK \ I I L SETBACK i) MEW DECK A pp - -A W A c` Li �STIMAT�D GRADE LEV5 1@ CORNERS - \ ` � mI I I 349•� 350 5 $ PROPERTY LINk 0 + \ - - N 89°4 '13" W 24264' I Ate. G DE LEVEL: \ ` 6MALLP5T RECTANGLE \ COUND RNER SAKE PERT� \ 1 I I FIELD MEASUREMENT I I I TO EDGE OF ASPHALT 340 1 34 \ 310 I 1 44 34(o 34 3 O I I CONTOUR INFORMATION IS AN INTERPRETATION OF INFORMATION FOUND ON SNOHOMISH COUNTY ONLINE PROPERTY INFORMATION G15 MAP. I I I I SITE PLAN '�' 2�' �' �O FT. iiiiiiiiiiiiiiiiiiiiiillillililig SCALE: i" = 20'-0" A 1 FIC PROVIDE ATTIC VENTILATION AS INDICATED ON ROOF FRAMING PLANS. THE NET FREE VENTILATING AREA SHALL BE NOT LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED, EXCEPT THAT THE AREA MAY BE 1/300, PROVIDED AT LEAST 40 BUT NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT t WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. IRC R8062. ATTIC ACCESS MINIMUM 22" x 30" WITH MINIMUM 30" HEADROOM, UNOBSTRUCTED, READILY ACCESSIBLE OPENING. IRC R801.1 TO BE IN COMPLIANCE WITH IRC R308 AND WASHINGTON STATE SAFETY GLA55 LAW GLAZING IN HAZARDOUS LOCATIONS SUCH AS GLASS ON DOORS, GLAZING WITHIN 24" ON EITHER SIDE OF A DOOR OPENING, AREAS WITHIN 60" VERTICAL AND 3(0" HORIZONTAL OF THE BOTTOM LANDING OF A STAIRWAY, STORM DOORS, RAILINGS, SHOWER DOORS, SLIDING GLASS DOORS, AND TUB ENCLOSURES SHALL BE SAFETY GLAZING MATERIAL. IRC R308.4 ALL EXTERIOR WALL GLAZING SHALL COMPLY WITH THE a )1')-EDITION OF THE WASHINGTON STATE ENERGY CODE. EGRESS IN EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY EXIT WITH A MINIMUM NET CLEAR OPENING OF 5.1 SQ. FT. THE MINIMUM NET CLEAR NI II E ROPE OPENING HEIGHT GNT D MENSION SHA LL BE 24 MI NIMUM IM UM NET CLEAR E LE R OPENING WIDTH DIMENSION OF 20" A`L) A FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE THE FLOOR IRC R310.1. ONE EXIT DOOR CONFORMING TO IRC R31U 15 REQUIRED. FIRE PROTECTION: SMOKE DETECTOR POWER SOURCES TO BE INSTALLED IN ACCORDANCE WITH NFPA 12 t IRC R314. ALL ALAIZI DEVICES SHALL BE INTERCONNECTED PER IRC R314.1. FIREBLOCKING PER IRC R1003.19, R1001.12, R302.11 t R602.8. DRAFTSTOPPING PER IRC R302.12 t R502.12. VENTILATION & LIGHTING: INHABITABLE ROOMS NOT PROVIDED WITH AN OPENABLE EXTERIOR OPENING OF AT LEAST 4% OF THE FLOOR AREA, A MECHANICAL VENTILATION SYSTEM MUST BE PROVIDED THAT PROVIDES MIN 35 AIR CHANGES PER HOUR IRC R303.1. DRYER t BATH FANS TO BE 50 CFM, AND RANGE/OVEN FANS TO BE 100 CFM MIN, VENT TO THE OUTSIDE. IRC303 AND 200(o WA STATE VENTILATION AND INDOOR AIR QUALITY CODE. NATURAL L*WTNG TO BE NOT LESS THAN S% OF THE FLOOR AREA OR ALL HABITABLE SPACES. IRC R303. BATHROOMS: ALL TUB AND SHOWER STALLS SHALL HAVE FIREBLOCKING BETWEEN STUDS ALL GLAZING USED FOR DOORS OR ENCLOSURES IN BATHROOMS SHALL BE SAFETY GLAZING. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING A SHOWER OR BATHTUB WHERE THE BOTTOM EXPOSED EDGE IS LESS THAN 60 INCHES ABOVE THE STANDING SURFACE AND DRAIN INLET SHALL BE SAFETY GLAZING. IRC R308.4 BATH TUB E SHOWER STALL NON -ABSORBENT WAINSCOTS SHALL BE A MINIMUM OF 12 INCHES ABOVE THE FLOOR IRC R3012. WATERCLOSETS SHALL HAVE MIN- 15" TO SIDE WALLS FROM CENTER OF FIXTURE, AND MIN. 21" FRONT CLEARANCE. IRC R301.1 APPLIANCES IN A FIXED POSITION SHALL BE SECURELY FASTENED IN PLACE TO STRUCTURAL MEMBERS WITH STRAP ANCHORS OR SIMILAR ANCHORING METHOD. IRC G2404A METHOD OF COMPLIANCE - PRESCRIPTIVE METHOD FOR GROUP R OCCUPANCY, CLIMATE ZONE PER TABLE R301.1, TABLE R402.1.1, UNLIMITED GLAZING. ALL MATERIALS, WORKMANSHIP AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL RESIDENTIAL CODE AND THE WASHINGTON STATE ENERGY CODE, LATEST EDITION. VERIFY ALL CONDITIONS BEFORE PROGEEDINa WITH WORK WALLS: INSULATED PER TABLE R402.1.1. ROOF AND D CEILING: INSULATED L ED PER TABLE R402.1.1. PROVIDE INSULATION IN CEILING WHERE POSSIBLE AND IN 2x12 RAFTERS IF VAULTED CEILING CONDITION EXISTS. MAINTAIN A MINIMUM OF 2" CLEAR BETWEEN TOP OF INSULATION AND BOTTOM OF SHEATHING FOR VENTING. VENTING MUST OCCUR IN EACH JOIST SPACE. WHERE CONTINUOUS VENTING WITHIN A JOIST SPACE IS INTERRUPTED BY A HEADER 0 E., SKYLIGHT OR AT HIP END), PROVIDE (2) 1 1/2" VENTING HOLES AT THE TOP OF THE RAFTER AT THE HEADER TO ALLOW FOR CONTINUAL THROUGH -VENTING INTO THE NEXT JOIST SPACE. FLOORS: INSULATE PER TABLE R402.1.1 SLAB ON GRADE: INSULATE PER TABLE R402.1.1. PROVIDE EXTRUDED RIGID CLOSED CELL INSULATION. INSULATION, INSTALLED INSIDE THE FOUNDATION WALL, SHALL EXTEND DOWNWARD FROM THE TOP OF THE SLAB 24" MIN. OR DOWNWARD AND THEN HORIZONTALLY BENEATH THE SLAB FOR A COMBINED 24" MIN. INSULATION INSTALLED OUTSIDE THE FOUNDATION SHALL EXTEND DOWNWARD 24" MIN. OR TO THE FROSTLINE. WSEC 402.2.9.1. VAPOR BARRIERS: VAPOR RETARDERS SHALL BE INSTALLED ON THE WARM SIDE (IN WINTER) OF INSULATION PER TABLE R402.4.1.1. FLOORS SEPARATING CONDITIONED SPACE FROM UNCONDITIONED SPACE SHALL HAVE MIN. 4 MIL POLYETHYLENE OR KRAFT FACED MATERIAL. ROOF/CEILING ASSEMBLIES WHERE THE VENTILATION SPACE ABOVE THE INSULATION IS LESS THAN AN AVERAGE OF 12 INCHES SHALL BE PROVIDED WITH A VAPOR RETARDER WALLS SEPARATING CONDITIONED SPACE FROM UNCONDITIONED SPACE SHALL HAVE A VAPOR RETARDER INSTALLED. FACED BATT INSULATION SHALL BE FACE STAPLED. A GROUND COVER OF MIN. 6 MIL BLACK POLYETHYLENE SHALL BE LAID OVER THE GROUND WITHIN CRAWL SPACES W/ JOINTS LAPPED MIN. 12" GLAZING AND DOORS: GLAZING AND DOOR U-FACTORS SHALL BE DETERMINED IN AGCORRDANCE WITH WSEC SECTIONS R402.1.1 AND R303.13(2), RESPECTIVELY. VICINITY PLAN Y i Earr�a: d:; SI 3� 18620 SSTH AVE WEST EDMONDS, WA W026 LOT NUMNBER: 00434600003302 ZONING CLASSIFICATION IRS 12 LEGAL DESCRIPTION ALL THAT PORTION OF TRACT 33, EDMONDS SEA VIEW TRACTS, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 3, OF PLATS, PAGE 16, RECORDS OF SNOHOMISH COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHEAST CORNER OF SAID TRACT 33, BEING THE CENTER OF INTERSECTION OF CONOVER STREET E HIGHLAND AVENUE: THENCE NORTH 0'360" EAST FOR 312 FEET TO THE TRUE POINT OF BEGINNING: THENCE NORTH 89°4413" WEST 262.04 FEET TO THE WEST LINE OF SAID TRACT 33: THENCE NORTH 0°3640" EAST ALONG SAID WEST LINE FOR 96 FEET± THENCE SOUTH 89°44'13" EAST 262.02 FEETt THENCE SOUTH 0°38'02" WEST FOR 96 FEET TO THE TRUE POINT OF BEGINNING± EXCEPT THE EAST 20 FEET FOR COUNTY ROAD, LOT COVERAGE LOT AREA: 23234.9 SF NOII EFRINO DIVISION EXIST!t1!G AREA: S AS NCOT,Ep HOUSE 2,1983 SF SHED: 100 SF &Ate:. I rCa �j EXISTING TOTAL: 2,8983 SF f ` EX{c,TING LOT COVERAGE: 125% ALLOWABLE LOT COVERAGE: 35% OWNWON MAGMR IS RESPONSIBLE FOR WIN CONTROL AND DRAINAGE SQUARE FOOTAGES EXISTING AREA IOusE 1,121 SF CARPORT 605 SF SHED 100 SF EXISTING AREA TOTAL: 2,432 SF EXISTING AREA REMOVED: CARPORT 525 5F EXISTING AREA REMAIN:. 1,904 SF ADDED AREA: HOUSE INFILL 12 SF GARAGE 539 $F ADDED AREA TOTAL: 611 SF TOTAL. AREA: 2,339 SF BUILDING HEIGHT SOOF HEIGHT: AVERAGE EXISTING GRADE (AEG): 5FF AO.1 FOR SPOT CALCULATIONS ALLOWABLE HEIGHT: SLOPED ROOF (25' + AEG) EXISTING SLOPED ROOF HEIGHT: PRU"OSED SLOPED ROOF ADDITION HEIGHT: AcTLkAL_ Nil t1z- 3(05 3 BUILDING CLASSIFICATION No Nc-v'J P r: N c L-0s I W 4 cA R-P o R T A N D I N Fk L L IF2� � i tN D'E�tZ00 N' Zone IZ S - I Z- Comer Flag Setbacks Required, --Actual Front '2c;� c 3 i Sides t L t� s Eg,J /o D Rear Zs Other I II Iecght _ 2- A �3 t 34955 FT. 7� 1510. 31455 FT, C 41.9 SEE ELEVATIONS , SEE ELEVATIONS b ' 347 . 'b i 31 a . `Z- Af 3`f01.ss u�r .rcvur c ItSC, (-HAt-'Itip K-3 (SINGLE FAM. RESIDENTIAL) CONSTRUCTION TYPE (IBC 602.5): TYPE VA ALLOWABLE AREA (IBC TABLE 503): UNLIMITED ALLOWABLE HEIGHT (IBC TABLE 503): 3 STORIES W1 BASEMENT, OR 4 STORIES IF SPRINKLED SPRINKLERS (IBC 903.3.13) NFPA 131D SYSTEM IF REQ'D FIRE FLOW (UFC TABLE A-llI-A-U YES/NO - +SPRINKLERS REQV =IF PROVIDED, INSTALL PER IFC503, 500 STRUCTURAL DESIGN - IRC PRESCRIPTIVE METHOD ENERGY COMPLIANCE WASHINGTON STATE ENERGY CODE:. y' EDITION, PRESCRIPTIVE FOR SINGLE-FAMILY RESIDENTIAL, CLIMATE ZONE 5 4 MARINE 4. U-FACTORS SHALL CONFORM TO TABLE R303.1.3(2), 31XIWj U-FACTOR CEILMG VAULTED CEILING WALL ABOVE GRADE WALL-INT BELOW GRADE WALL-EXT BELOW GRADE FLOOR SLAB ON GRADE RT. OVERHEAD 030 0.50 R-45 R-36 R-21 -21 R-10/15/21 R-30 R-10 B Int. + TB 2' r n N TACTS OWNER rti2rut Sr Sr: �:`j i f � F �'�� ��-'��/ t � � •D • H AI3B RE VIATIONS a�J UNLESS NOTED OTHERWISE N 'ZT IN CONTRACT LC JATER CLOSET E/3l EXISTING F11 ROOM NTS NOT TO SCALE LLD WOOD APPROVED By PLANNING CITY OF EDNIr'f4DS BUILDING DEPAF FNIENT WORK Lli�_- L ADDRESS1 OWNER ` (2_VS APPROVED DATE: BLDG.OFFICIAL: PIEf,s. `T IN .AMBER �- ao1(0 STRUCTURAL ENGINEER INDEX OF DRAWINGS COVER SHEET/SITE PLAN A0.1 COVER SHEET t SITE PLAN ARCHITECTURAL .I MAIN FLOOR PLAN -.L r !M. ;:i FvATint,15 Al2uiI STRUCTURAL .I FOUNDATION AND MAIN FLOOR FRAMING PLAN ROOF FRAMING PLAN IRECEM Remodel 18620 88th Ave W, Edmonds, WA 98021 NO. DATE REVISION DATE: 05/02/201E FILE: AO.1 COVER SHEET AOM WEE DEC 2 0 2016 DEVELOPMENT SERVICES C1 CITY OF EDMONDS MAW 2016 1619