1864_001.pdfFIRE DISTR T Fire Alarm Checklist cp Ilk\ 7P po Name of Building or complex Date Y-11-i9 Address 7q1to Permitnumber �?Oi8o(,V7 Fire alarm system complete and �ire alarm system pre -testing complete Building occupants (if applicable notified of fire alarm testing System is in test mode SnoCorn has been notified Knox box has been provided Remote annunciator is roperly located, accessible, not obstructed and conforms to approved plans Pull station installed in FACP room or adjacent to. Fire alarm control panel is properly located, accessible, and not obstructed and conform to approved plans. Approved signage has been provided. This includes signage to specific locations and specific features. ( ie. Dry Standpipe and FDC) Provide the alarm monitoring company's name and 24 hr number on the control panel. Monitoring company's name 4.1_41ttm (a-rio'caL Provide a manual pull station reset key(s) as needed for the Knox box. System loss of ac power, verify operation standby power AES check list completed (on reverse side) - N 10 Fire alarm control panel circuit breaker shall be labeled FACP, painted red, and locked in the ON position. fiFire alarm panel shall indicate what circuit breaker supplies power and the location of the panel where that circuit is located. Check a random selection of initiating devices (minimum of 25%) —O�L' Activation of audible, visual and audible / visual devices. Verify visual synchronization Outside horn / strobe activation and location Verify alarm, supervisory, and trouble retransmission signals to monitoring station Require Certificate of completion from _installe��x�mple EmAzLV Signature of Fire Official 12425 Meridian Avenue S / Everett WA 98208 / 425-551-1200 www.firedistrict1.org SNOHOMISH co' FIRE DIST 1-CT Wireless Mesh Network (AES) Installation Inspection Checklist All AES radio transmitters shall be installed and inspected according to NFPA 70, NFPA 72, WAC, manufacturer requirements/recommendations. • The AES Radio is mounted near the FACP in a temperature controlled environment. If it is mounted on the interior side of an exterior metal, concrete, or block wall it is mounted on an insulating board to prevent direct contact with moisture or temperature extremes. Alternate locations, if approved by the fire marshal may require the AES Radio to be located inside a lockable NEMA 4X enclosure with smoke detector and thermostatically controlled heater. • AES routing table shows a minimum of two (2) "good" paths with a net -con of 0-5 prior to connecting to FACP. • AES is protected by a smoke detector. • A/C transformer to AES is protected inside a secured transformer enclosure. • The A/C transformer is one of the following 3 models; AMSECO model XF1640, Elk Products model TRG1640, or MG Electronics model MGT1640. • Wires from A/C transformer enclosure to AES enclosure are in conduit. • AES is powered via dedicated A/C circuit or shared with a dedicated circuit to FACP. • A/C breaker to AES circuit is labeled and provided with a lock -on device. • All exposed wiring below seven feet (7� AFF is protected in conduit. • Coaxial cable outside the AES enclosure is installed in conduit. • Exterior antennas are protected by a lightening arrester. Arrester is located a minimum 6'from AES radio and grounded to earth with a minimum 6 AWG copper wire. • All bends in the coaxial cable outside of the AES enclosure (if applicable) have a minimum six inch (6'� radius. • AES AND IntelliPro Fire or FireTap (if installed) is locally supervised at the protected premises (both audibly and visibly) in an approved manner for antenna cut, low battery, communication troubles, and charger fault as a separate zone or address on the FACP. (14 outputs) • General alarm (zone 1), general trouble (zone 2), and supervisory (zone 3) outputs from the FACP are connected to supervised input zones on the AES. • All zones, signals, or addresses capable of being transmitted by the FACP are transmitted to the central station. This may require an IntelliPro Fire or FireTap. • A current Routing Table showing the NetCon, Link Layer, and Signal Strength (minimum 2 "Good" paths with a minimum NetCon of 5 or less) is to be provided to the Fire Inspector at time of final inspection. 12425 Meridian Avenue S / Everett WA 98208 / 425-551-1200 www.firedistrict1.org