Loading...
186578344-1122 Viewland Way.pdfROW PERMIT NO. : ENG___________ ISSUE DATE: ________________ RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: CONTACT: CONTRACTOR: Phone #: Mailing Address: Fax #: State License #: Email #: City Business License #: Liability Insurance Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: Commercial Subdivision City Project Traffic Control (Only) Multi-Family Single Family Other EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? Yes No ANY ASSOCIATED PERMITS? BLD#____________ ENG#____________ DESCRIPTION OF PROPOSED WORK (Be Specific) : _________________________________________________________________________ WAS STREET OVERLAYED WITHIN THE LAST FIVE (5) YEARS? YES NO Year: PAVEMENT CUT: Yes No If yes, indicate size of cut: _________x_________ CONCRETE CUT: Yes No If yes, indicate size of cut: _________x_________ RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street-cut trench work shall be patched with asphalt or City approved material prior to the end of the workday – NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE DATE Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE EDMONDS / VIEWLAND WAY IFS CREW REPLACED 12FT OF 2" PE TO REPAIR BROKEN MAIN SHORELINE CONSTRUCTION IS RESPONSIBLE FOR PERMANENT RESTORATION 1111 1111 10 1019 19 VIEWLAND WAY O L Y M P I C A V E STOP FLAGGER STOP FLAGGER STOP FLAGGER CROSSWALK CLOSED R9 - 3 CROSSWALK CLOSED R9 - 3 ON E L A N E RO A D AH E A D W20-4 X'X'X' RO A D WO R K AH E A D W20-1 W20-7A ONE LANE ROAD AHEAD W2 0 - 4 X' X' X' ROAD WORK AHEAD W2 0 - 1 W2 0 - 7 A ONE LANE ROAD AHEADW2 0 - 4 X' X' X' ROAD WORK AHEADW2 0 - 1 W2 0 - 7 A ON E L A N E RO A D AH E A D W20-4 X'X'X' RO A D WO R K AH E A D W20-1W20-7A STOP FLAGGER M6-2 M6 - 2 RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE USE MAXIMUM AVAILABLE SPACE FOR SIGNS 1100 N PSE PUGET SOUND ENERGY JOB#186578344 1100 Viewland Way, Edmonds, WA May 31, 2018 brent.pogson@pse.com (425) 398-6158 Sheet 1 of 1 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 008997 Card Exp. 08/13/2019 gregory.harwood@pse.com (425)424-6425 CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 MINIMUM TAPER LENGTH = L (feet) LANE WIDTHS POSTED SPEED LIMITS 20 25 30 35 40 45 10 11 12 55 + 60/65 45/55 35/40 30 25 SIGN SPACING "X" 800 500' 350' 200' 100' Notes: 1. All signs and spacing to conform to the MUTCD and City of Edmonds standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m 8. Work area will be 8' SCL of Viewland Way & 32' ECL of Olympic Ave. 9. If used, place NO-PARK signs 72 hours in advance of the day that the work is to be done. BORE PIT 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY ROW ROW 1230 1214 1135 1225 1206 1114 1116 1122 1218 1224 1126 1217 1132 1118 1123 1115 11251020 1225 VIEWLAND WAY OLYMPIC AVE 29'S 19'N 33'E 28'E CL PAV 19'E 2" PE IP 2'S-S EDGE PAV 853167 2" MPE IP 19'E 9518125 2" PE IP 18'E CL PAV 853167 1 1/4" MPE IP 7'N 9601174 1 1/4" MPE IP 5'N 9601174 2" PE IP 13'E 902206 2" MPE IP 20'-25'N 186528658-2004 2" PE IP 1'N-N PAV 853167 1 1/4" PE IP 4'S-N PL 883358 249'N 246'N 325'E315'E 28 0 ' W 16 7 ' W 206'N 461'N 309'N 166'N 33'W 49'W 137'E 154'W 23 3 ' E 13 0 ' E 28'S 314'S 15'E 1 1/8" MPE2016-E 5/8" PE1990 5/8" MPE2000 5/8" PE1985 5/8" PE1988 5/8" MPE1999 1 1/8" MPEI2011-E 5/8" PE1993 5/8" PE1992 5/8" PE1988 5/8" M1996 5/8" PE1989 5/8" PE1989 5/8" MPE1996 5/8" MPE1996 1996 5/8" 5/8" PE1994 1 1/8" MPE2009 5/8" 360'N 169'E 17'E 358'E No electric grid information availableS160062, Q162067 The information on the attached maps is subject to change without notice. Puget Sound Energy makes no warranty, expressed or implied, concerningthe suitability of this information for any purpose. Recipient agrees to not disclose this confidential information to any other person or entity,unless authorized in writing by Puget Sound Energy. This map is not to be used for determining the actual location of any PSE facilities (call 811).“ 05-07-2018 Scale 1:800 Lat\Long=47.8197, -122.3615