19804 81st PL W-SITE PLAN.pdfCLIMATIC & &W&RAFHIG 12551&N CRITERIA (R3o1.2U)) ROOF SNOW LOAD J WIND 5i°EED TOPOGRAPHIC EFFECTS 5E15MIC f DESIGN CAT. a WEATHERING FROST LINE �P I H b TERMITE WINTER DESIGNe tGC BARRIER UNDERLAYME hT FLOOD HAZARDS ! AIR FRECZING MEAN ANNUAL TEMP REQUIRED INDEX ' TEMPI ZG� pjGj NO PZ MODERATE 12 51 IGHT TO 22 NO 110** MRM 170 5! MODERATE 2015 W5EC Br IRG VENTILATION TABLE 4o2.1.1 CLIMATE ZONE MARINE 4 (R-VALUE (a) OR U-FACTOR) FENESTRATION U�FACTOR (b) 0.30 SKYLIGHT (b) U-FACTOR 0,00 GLAZED FENESTARTION SHGG (b,e) N/A 40 21 Int. CEILING R-VALUE (k) WOOD FRAME WALL (g,m,n) R-VALUE MASS WALL R-VALUE (I) 2V21 (h) FLOOR R-VALUE 30 (g) BELOW -GRAPE (c,m) WALL R-VALUE 10/15/21 Int. +TB 5LA3 (d) R-VALUE Sr PEPTH 10, 2 4, FOR 51: 1 ¢00t =304,8mm, .I. - CONTINUOUS INSULATION, Int.= INTERMEDIATE FRAMING (a) R-VALUES ARE MINIMUMS. LI-FAGTORS AND 5HGC ARE MAXIMUMS. WHEN iN%L.ATION 6INSTALLED IN A CAVITY WHICH IS LE55 THAN THE LASH OR DESIGN THICKNESS OF THE INSULATION, THE COMPRE55ED R-VALUE OF THE INSULATION FROM APPENDIX Alai SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED (b) THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS, THE SHGG COLUMN APPLIES TO ALL GLAZED FENESTRATION. EXCEPTION: %YUGHT5 MAY BE EXCLUDED FROM GLAZED FENESTRATION SHGC REQUIREMENTS IN CLIMATE ZONES I THROUGH 3 WHERE THE SHGC FOR SUCH SKYLIGHTS DOES NOT EXCEED 0.30 (c) 10/I5i/21 MEANS R-la CONTINUOUS INSLLATION ON THE EXTERIOR OF THE WALL, OR R-15 ON THE CONTINUOUS INSULATION ON THE INTERIOR OF THE WALL, OR R-21 CAVITY INSULATION FLUB A THERMAL BREAK BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF THE BASEMENT WALL, 10/10/21+TB SHALL BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE WALL. TB MEANS THERMAL BREAK BETWEEN FLOOR SLAB AND BASEMENT WALL. (d) R-10 CONTINUOUS INSULATION t5 REQUIRED UNDER HEATED SLAB ON GRADE FLOORS. 5EE R402.2.®.1 (e) THERE ARE NO SHGG REQUIREMENTS IN THE MARINE ZONE (f) (g) (h) RESERVED 0) THE SECOND R-VALUE APPLIES WHEN MORE THAN HALF THE INSULATION 15 ON THE INTERIOR OF THE MA55 WALL. 0)RESERVED (k) FOR SINGLE RAFTER OR J015T VALLTED GEIUNGS, THE INSULATION MAY BE REDUCED TO R-38 (1) RESERVED (� INT. (INTERMEDIATE FRAMING) DENOTES STANDARD FRAMING 16 INCHES ON GENTER WITH HEADERS INSULATED WITH A MINIMUM OF R-10 INSULATION. (N) LOG AND 50LIP TIMER WALLS WITH A MINIMUM AVERAGE THICKNESS OF 3.O INCHES ARE EXEMPT FROM THIS INSULATION REQUIREMENT TABLE R40VZ, FOOTNOTE: (a) NOWENE5TRATION U-FACTOR5 SHALL BE OBTAINED FROM MEASUREMENT, CALCLLATION OR AN APPROVED 50URCE OR AS SPECIFIED IN SECTION R402.1.3 GENERAL NOTES: THESE GENERAL NOTES ARE TO BE U5EP AS A SUPPLEMENT TO THE DRAWINGS. ANY PISCREPANCIES FOUND AMONG THE DRAWINGS, GENERAL NOTES AND 51TE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH PISCREPANCY IN WRITING. ANY WORK PONE 15Y THE CONTRACTOR AFTER THE D15COVERY OP A DISCREPANCY SHALL BE DONE AT THE CONTRACTORS OWN RISK. ALL METHODS ANP MATERIALS TO CONFORM TO THE 2015 INTERNATIONAL BUILDING COPE, 201r2 INTERNATIONAL RESIDENTIAL COPE AND 2o1r2 WASHINGTON STATE ENERGY COPE AS AMENDED ANP APOPTEP BY APPLICABLE ,JURISDICTION. DESIGN CRITERIA (IRO 301): THE ENGINEERED LATERAL PE519N FOR THE BUILDING IS IN ACCORDANCE WITH THE ZOO INTERNATIONAL BUILDING COPE AND IS PROVIPEP BY THE ENGINEER OF RECORD. DESIGN LOAPS: ROOF: LL=2rv, DL=1yi, TL=40 FLOOR: LL=40, PL=10, TL=5o CONCRETE FOUNDATIONS_ CONCRETE FOUNDATIONS SHALL BE DESIGNEP IN ACCORDANCE WITH IRG CHAPTER 4• MIN, CONCRETE COMPRESSIVE STRENGTH (f'-) : 3,000 PSI (R404.1.2.3•I) MIN, YELP STRENGTH OF STEEL REINFORCEMENT: 60,000 PSI (R404,1.2.3.7.1) CONCRETE MIXING Sr DELIVERY SHALL COMPLY WITH A5TM C 04 OR ASTM G MIN. REINFORCEMENT COVER: 3" CAST AGAINST EARTH, L5" TO REMOVABLE FORMS FORMS SHALL BE MADE OF AN APPROVED MATERIAL AND SHALL PROVIDE SUFFICIENT STRENGTH TO CONTAIN CONCRETE DURING THE CONCRETE PLACEMENT OPERATION (IRG R404.1.2.3•&) CONCRETE SHALL. BE CONSOLIDATED BY SUITABLE MEANS DURING PLACEMENT AND SHALL BE WORKED AROUND EMBEDDED ITEMS ANP REINFORCEMENT AND INTO CORNER OF FORMS (IRC 404.1.2.3.5) VERTICAL AND HORIZONTAL WALL. REINFORCEMENT SHALL BE THE LONGEST LENGTHS PRACTICAL. WHEEZE SPLICES ARE NECE55ARY IN REINFORGEMENT, THE LENGTH SHALL BE IN ACCORDANCE WITH TABLE R&II-0.4(I) AND FIGURE R(ol1.5.4(Q. THE MAXIMUM GAP BETWEEN NON -CONTACT PARALLEL BARS AT A LAP SPLICE SHALL NOT EXCEED THE SMALLER OP ONE -FIFTH THE REQUIRED LAP LENGTH ANP (o INCHES. FOR GRAPE (00 STEEL *4 BAR (TABLE -LAP SPLICE LENGTH -TENSION = 3o INCHES -TENSION DEVELOPMENT LENGTH FOR STRAIGHT BAR - 23 INCHES -TENSION DEVELOPMENT LENGTH FOR 00-DEGREE AND I80-DEGREE WITH NOT LESS THAN 2.ri INCHES OF 51PE GOVER PERPENDICULAR TO PLANE OF HOOK AND 00-12E91ZEE STANDARD HOOKS WITH NOT LE55 THAN 2 INCHES OF GOVER ON THE BAR EXTENSION 15EYONP HOOK = 0 INCHES -TENSION PeVELOPMENT LENGTH FOR BAR WITH 00-DEGREE AND ISo DEGREE STANDARD HOOK HAVING L E!66 COVER THAN REQUIRED ABOVE = 12 INCHES. PAMPPROOFING (IRG R40(o): FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR 5PACE5 AND FLOORS BELOW GRADE SHALL BE PAMPPROOFED FROM THE TOP OF THE FOOTING TO THE FINISHED GRADE. CONCRETE WALLS SHALL BE PAMPPROOFEP BY APPLYING ANY ONE OF THE MATERIALS LISTED 1N R 406,•1 & R406.2 SMOKE ALARMS (R314 ALL SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH ULZI7 AND 05TALLEP IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE ANP THE HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. SMOKE ALARMS SHALL BE IIOV INTERCONNECTED WITH BATTERY BACK-UP. FIREBLOCKING: SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS AND TO FORM AN EFFEGTIVE FIRE BARRIER BETWEEN STORIES AND BETWEEN TOP STORY AND ROOF SPA(--E• INSTALL PER IRC 302•II FA5TENER5 IN PRESERVATIVE TREATED WOOD (RN7.3.I FASTENER5, INCLUDING NUTS AND WASHERS, FOR PRESERVATIVE TREATED WOOF SHALL BE HOT DIPPED ZING -COATED, GALVANIZED STEEL, 5TAINLES5 STEEL, SILICON BRONZE OR COPPER. DRIP EDGE (IRO R00rp.2.8.5): A DRIP EDGE SHALL BE PROVIDED AT EAVE5 AND GABLES OF ASHPALT 5HIN9L.E ROOFS AND SHALL EXTEND 15 INCHES BELOW SHEATHING AND 2" UP ROOF DECK ta 0 5L �N 51TE PLAN- 0HRI5TEN5EN RE5IDENGE SCOPE OF WORK: CONSTRUCT NEW 33(o S.F. ATTACHED GARAGE PROPERTY INFORMATION: IMPERVIOUS SURFACE COVERAGE: HEIGHT CALCULATION: PARCEL s�: 00(o03400001000 ADDRESS: 10804 815T PL W EPMONPS ZONING: RS-S LOT AREA: 0,712 5•F• SETBACKS: FRONT: 20' REAR: 10' SIDEYARP: 7.r2' MAX. HT: 25' LOT COVERAGE: 35% PARKING 5PACE5: 2 or ' O.H. + 000 5TAIR5 & WALK-O.H. 134 GARAGE + (o OF 2 O.H. 340 DRIVE (- O.N.) 277 TOTAL 2271 LOT AREA 8712 IMPERVIOUS COVERAGE A 384.3 B 381.3 C 37vR P 382.5 AVERAGE FINISH GRADE 381.0 MAX. HEIGHT- ALLOWEV: 3860 +G�j 40".0' ACTUAL HIGHEST RIDGE: 20•75' = 402.05' r l I I� �II I I� E I I II I I I I I II I � I I I I 1 I I � III I GVi�ii&VOOOIN—I nA,90R iS RESiz'G i 403i6L2: FOR EROSION (;ON Rn1, Nn DRAINAGE Applicant shall repair/replace all damage to i utilities or frontage improvements in City right -of -Way per City standards that Is caused or occurs during the permitted project. LEGAL PE5CRIPTION: VALLEY HI 15LK 006P P-00 - LOT 10 �► i�icru �u OR iS r;ESPONS)IBLE ('OR EROSION i;UIN-M-10L AND DRWN'Ar--`E OWK40 GTGA R4ESPONS191-E M LOCATING ALL ON -SITE UTILITIES. AELACATIOWREVISKON TO AW UTILITYS MAY AEA 6EP149ATE PERIVIRL 1. . f— uc 0 z SCALE: i"=lo'-o" ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE LOT UNE STAKES MUST BE IN PLACE AT TIME OF FOUNDATION INSPECTION "Nothing in this t approval proom Shall be itottarpretad as �or permitting the maintenana of any currently emsting illegal, noumfilemW or unpern it d building, structure or site condition which is outside the scope of the ' N10MOOR, regardlese of whether such D �AructUre or condition is shown on the vat wing. Such building. structure or ay maybe the subject of a Separate en'ioroement action." 9 • •,1 , • 1 Cone CornerFlag Setbacks Required Actual Front Q t7 Sides S Rear �`?, ►� = ' Other Bei t__ � �q a�c�, ac�'�fi� IesS 't-'►�a-, 25� 1 n IVA� CITY OF EDMONDS BUILDING DEPARTMENT WORK ADDRESS j W OWNER APPROVED DATE: Z Zoi /r7 BLDG. OFFICIAL: PERMIT NUMBER VICINTIY MAP, AREA GA ULATION -I GARAGE: 33(0 SHEET INDEX G COVER-C>ENERAL NOTES I FOUNDATION PLAN 2 MAIN FLOOR PLAN 3 ROOF FRAMING 4 ELEVATIONS 5-- STRUCTURAL PETAIL5 CITY COPY RECEIVED OCT 2 3 2017 BUILDING z LLJ W~ w�� LLJ cn z Lda �L� Y O fo)00 LU �CO �� N CV U0) Q C 0i E t (1)o 0 C: C Y w (D0 LL ON 00 � 00 z°: U I <- n 71 Z O UJ n' c 1L O iu a- F o 06 N Z O UJ 0 .. (3 W UJ U) W LLJ O U J013 # 17-048 PATE: 019-27-1 SHEET # 2.ri' 0' 10' 20' 4c