Loading...
20040560.pdfDATE RECEIVED 4 CITY OF EDMONDS CONSTRUCTION PERMIT APPLICATION OWNER NAME/NAME OF BUSINESS _L\J� 1i (' 10 L - �7�c W MAILING ADDRESS W z 0 CITY ZIP k�l TELEPHONE i . - . ADDRESS --KICA- ZT2, CITY Ue- ZIP TELEPHONE 7211 Lk — 211 NAME I CBL ts I ADDRESS I :m cq- 212-1-111 e� CITY ZIP STATE LICENSE NUMBER 'A 16 ) V ) I I _11r TAX ACCOUNT PARCEL NO. TELEPHONE ::-I- _j - ( (. ) �XPIRATION DATE A . I (-I . / - 6-Itz -&-NEW -.Z-RESIDENTIAL ADDITION COMMERCIAL REMODEL MULTIFAMILY REPAIR 'YDS DEMOLISH TANK GARAGE RETAINING WALL CARPORT ROCKERY CrYPE OF USE, BUSINESS OR ACTIVITY) EXPLAIN.- e._� : I L\�M I �< NUMBER NUMBER OF OF DWELLING STORIES UNITS DESCRIBE WORK TO BE DONE 1\)I L��\/\-J (" ( l;­IE URCE t�_, illso, 'PLAN CHECK NO: V -:z '7/ PERMIT EXPIRES L USE PERMIT ZONE NUMBER JOB SUITE/APT# ADDRESSr' PLAT NAME/SUBDIVISION NO, LOT NO. LID NO. /8 7 lkvci,�Nor�;j) LID FEE $ TESCP Approved PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP RW Permit Required Street Use Permit Roq'd EXISTING PROPOSED inspection Required sidewalk Required Underground REQUIRED DEDICATION FT wiring required METER SIZE LINE SIZE NO. OF FIXTURES PRV REQUIRED Y ES ES NO REMARKS OWN E R/CON TRACTOR RESPONSIBLE FOR EROSION CONTROUDRAINAGE IZEO'l N:s t-'Ec -r / n r,4 Cs) ('VtSg:Z0_�, i n i(ArCQ iiii` EERING REVIE ),-/I Q REVIEWED BY DATE :L/./ DATE VARIANCE OR CU SHORELINE OR ADS# I INSPECTION I BOND BY REWi POSTED DYES �kNO Is SEPA REVIEW SIGN AREA HEIGHT COMPLETE EXEMPT ALLOWED PROPOSED ALLOWED PROPOSED EXP PLUMBING / MECH LOT COVERAGE REQUIRED SETBACKS (FT.) PROPOSED SETBACKS (Fr.) ALLOWED. PROPOSED FRONT SID� ] ,;R,.,,,FRgNT 1.4RSID� REAR, 3 4Z COMPLIANCE OR .3 q z CHANGE OF USE z 5 Yc' —7 .7 6' �L7 PARKING OT AREA I P(�NINCG REVIEWFO Y DATE 5 EO SIGN R , 'D I PRQ�IDED 61 /0 q FENCE k 6 5 W ( X FT) REMARKS OTHER FIRE SPRINKLER FIRE ALARM C��EKED BY TYPE OF C RUCTION CODE OCCUPANT GROUP CRITICAL 12- AREAS SPECIAL INSPECTION JAREA OCCUPANT NUMBER -1,2 �r � ]�� REQUIRED M I LOAD )Iz_ YES Cl REMARKS PROGRESS INSPECTIONS PER UBC 108/FINAL INSPECTION REQ1D FEE Description FEE State Surcharge City Surcharge / 7 �!, // c/ 4:::� Mechanical THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO t BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC Grading DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE o SEPARATE PERMISSION. Engr. Review cc zV-40- ut PERMIT APPLICATION: 180 DAYS CL PERMIT LIMIT., I YEAR - PROVIDED WORK IS STARTED WITHIN 180 DAYS Engr. Inspection SEE BACK OF PINK PERMIT FOR MORE INFORMATION Cn Fire Review Plan Chk. Deposit (n 'APPLICANT. ON BEHALF OF HIS OR HER SPOUSE, HEIRS. ASSIGNS AND SUCCESORS uj IN INTEREST, AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE CITY OF 2 EDMONDS, WASHINGTON, ITS OFFICIALS. EMPLOYEES, AND AGENTS FROM ANY AND Fire Inspection Receipt # ALI- CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE Landscapelnsp. Total Amt. Due DEEMED TO MODIFY, WAIVE OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE 0 NOR LIMIT IN ANY WAY THE CITY'S ABILITY TO ENFORCE ANY ORDINANCE PROVISION,' X1 Recording Fee Receipt # I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT THE INFORMATION APPLICATION APPROVAL GIVEN IS CORRECT, AND THAT I AM THE OWNER, OR THE DULY AUTHORIZED AGENT OF THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRLIC- CALL This application is not a permit until signed by the TION, AND IN DOING THE WORK AUTHORIZED THEREBY. NO PERSON WILL BE EMPLOYED Building Official or his/her Deputy: and Fees are paid, and IN VI,01:A ON OF THE LABO 1700i� OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION receipt is acknowledged in space provided. W?RKME S COMPENSATA URA E AND RCW 18.2T OFFIC41AUS SIGNATURE DATE (425) ,tGNAOTU (bWNER A6 NT DATE SIGNED _'7 771 RELEASED BY, .0220 -4'� dATE 'I�E ATTENT)bN EXT 1333 7//, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL L A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI- ORIGINA11,�fjL�� YELLOW - INSPECTOOR CATE OF OCCUPANCY HAS BEEN GRANTED. UBC SECTION 109 PINK - I ASSESSOR 04/02 PRESS HARD -YOU ARE MAKING 5 COPIES GREEN - ACCOUNTING GLAZING % L SLO % iA /47 "ESTED DATE VALUATION $ Description Plan Check Building Permit z 0 M (j) M M 0 --i C) 0 C: --I K X M M Z ID --I C X (n 0 _n n X > M M 0_(1) 0 r_ 0 M Cn Cn M 0 Z z __4 X 0) z 0 A 0 ITI I I SITE BENCHMARK 55MH TOF'387.54 - , "r" A- 7, ( ril :S,0 4 i .n�- -� q�R qon 0 r `1� ne. P, `50 z Nx r�'W-XTER > 7-- LIN E7% , 'a C #3-TYPE 1 1 uj -u r - foF, = 40,0.9..,-r* ri V6A Q�ADING I E (5 -y4-44 - 0t714- I N 2 ' )7 ;�nili ROCKERY A 1�) L 407.3�OUT 'RY PERMIT G_)!PT,()T GYR AT 470 29.50' D RF.C:FIVF 40�396 3 8 0 4921 JUL 7 20b4 -40*-O,rop-404.20 SS I E - 395.55 P6RMIT COUNTER - -------- - I --- , 0141Z� ,416 i A'i 9 422 /4,24 AVE. GRADE 03.25' B. 414.75'(409.75+419.75'/2) C. 425.00' D. 404.00' 7-4= 411.75' MAX HEIGHT: 436.75' ACTUAL HEIGHT: 436.75' FOOTING= 403.50' SLAB = 412.00' 1STFL. =412.00' 2ND FL. = 422,00' IMPERVIOUS AREA BUILDING: 2,838.01 SQ. F1'. DRIVEVVAY- 750.03 SQ. FT. DECK: 118.77 SQ. FT. PATIO: 170.67 SO. F-E TOTAL: 3,384.35 SQ. Fr. LOT COVERAGE: 2,385.25/9,638.00 = 25%, PTA: 003-7360-0501-502 FILTER FENCE -426 WATER & SEWER INSPECTION REQ-0 CD/ CALL 425.771,0220 EXT 1326 FOOTING DRAINS NOT TO 13E TIED INTO DETENTION 5Y5TEM 8 TEMPORARY CONSTRUCTION ENTRANCE REQ'D 77 w—,*. I ALL EXPOSED SURFACES TO "LA 13E COVERED WITHIN 2 DAYS CONTRACTOR 15 RE5PON51DLE SCALE: I" = 20'-0" FOR ER05ION CONTROL & DRAINAGE 9 comer No Flag Yt Zone Setbacks red Actual Front T-6 7 6' IG q Sides -7 7 Rear 11�7 Other H�Zht Height Calculation Worksheet Address: 49K'J M 'J&js 4 A _VI Date: A - 2 Inspector(s): Dn 4�, 1. Datum Point: 2. Datum Point Elevation: if 3. AverageGrade: .4. Maximum Elevation AHowed: LIU,- '25" .7�(aver-Age e)' -S &ad + 5. Reference Point Elevation Shot to House: 'shot to house) I �0, 0 3 B(datum elevation)— 2-7-2.2 (grade to transit level tine 6. Measurements from line shot onto house to roof ridge: 14 Totid 7. Actual Elevation: -LLLc,� (reference point elevation) + 2-L A4 -(measurements from #6) Conclusion: es than 4U,T (allowed); therefore the house is/ (actual) is greater /0 is not over the height requirement per ECDC 16.20-30 requirements z 0 i 0 M r-"""ITY COPY DONNA L. BRESKE, P.E. 6621 Foster Slough Rd. Snohomish, WA 98290 Phone: 425-334-9980 Fax: 425-334-7380 DETENTION SIZING WORKSHEETS FOR MICHEL CONSTRUCTION INC RECEIV 4-LOT SHORT PLAT MAY 2 4 2004 PERMIT COUNTER DATE: MAY 1, 2003 SITE: 8715 BOWDOIN WAY EDMONDS, WA 98026 2W-3 DRAINAGE - DETENTION - INSPECTION - GRADING & TESC SEWER & WATER - FEASEBILITY - SITE DEVELOPNIENT z 0 M SHARE)) 1�r_C255 PRIV5WAY- IMP ARE�9 = 1�570 SF TABLE 1 — DETENTION PIPE SIZES IMPERMEABLE REQUIRED PIPE DIAMETER AREA SO FT VOL CU FT 15" 18" 24" 3011 2000 50 40 28 16 10 2500 62 3000 75 50 35 20 13 60 42 24 15 REQUIRED PIPE 3500 87 70 49 28 18 LENGTH IN FEET 4000 100 4500 112 80 56 32 21 90 63 C3�) 23 z 5000 125 100 70 _4D 25 0 NOTE: ALLO VABLE PIPE MATERIALS ALLOWABLE TIGHTLINE MATERIALS 0 m rRoNFORCED CONCRETE 'ED SDR35 (ASTM D-30,54) PVC N —12 ADS (DOUBLE WALLED) IZ STEEL )MINI ALu )AL MINUM (16GA) U, SCHED 40 PVC CD m 0 M Mp (ASPHALT COATED) HANCOR (F81 0) PVC c M 0 CN-12 ADS (2' MINIMUM COVER UNDER ROADS/DRIVEWAY S) 0 —1 0 0 IT! TABLE 2— OUTLET ORIFICE SIZES m z c —Z > --I IMPERVIOUS SO FT OUTLET ORIFICE DIAMETER (INCHES) 3: cn -AREA 2000 5/8 0 -n -n 5/8 3/4 3000 3500 3/4 MITI 0 U5 4000 ­00-4500 7/B 0 0 M C cn 5000 7/8 9 cn M 0 Z r- TABLE 3— RECTANGULAR CATCH BASIN REQUIREMENTS [TABLE 3— RECTA NGU DETENTION MAX SIZE **CATCH BASIN 3: > z PIPE DIAMETER KNOCKOUT TYPE <18" 20" TYPE 1, CB 15 3: cn 18" TO 24" 2611 TYPE IL, CB 16 - z 24" TO 36" 3611 TYPE 11, CB 19 �48 BASIN� 0 36" TO 42" 42" TYPE 11, CB 19 54" BASIN m **SOURCE: ASSOC. SAND AND GRAVEL CO. STDS. N:* A REVISIONS STAN DAR D D ETAI L DAlr__ TABLE OF STANDARD RESIDENTIAL DETENTION SYSTEM SIZES 1890-19913 DATE 7/24/01 SCALE NTS DWG NO. E5.12 LOT-2 IMPERVIOD5 PrRP4 000- 5r' Or- 3 ck Lo-r- TABLE 1 - DETENTION PIPE SIZES IMPERMEABLE REQUIRED PIPE DIAMETER AREA SQ FT VOL CU FT 15" 18" 24" 301p 2000 50 40 28 16 10 2500 62 50 35 20 13 3000 75 60 42 24 15 REQUIRED PIPE 3500 87 70 49 18 LENGTH IN FEET —0'4000 100 80 56 21 4500 112 90 63 36 23 5000 125 100 70 40 25 NOTE: ALLOWABLE PIPE MATERIALS ALLOWABLE TIGHTLINE MATERIALS REINFORCED CONCRETE ALUMINIZED STEEL SDR35 (ASTM D-3034) PVC N-12 ADS (DOUBLE WALLED) ALUMINUM (1 6GA) SCHED 40 PVC CMP (ASPHALT COATED) HANCOR (F81 0) PVC N-12 ADS (2' MINIMUM COVER UNDER ROADS/ DRIVEWAYS) TABLE 2- OUTLET ORIFICE SIZES IMPERVIOUS OUTLET ORIFICE DIAMETER (INCHES) AREA SID FT 2000 5/8 5/8 3000 3/4 3500 3/4- --lim-4000 C7/8) 4500 7 8 7- 5000 7/8 FABLE 3- RECTANGULAR CATCH BASIN REQUIREMENTS DETENTION MAX SIZE Leklr%�I�r%l 1r, "CATCH BASIN -rvmrr <1 8" 20': TYPE 1, CB 15 18" TO 24" 261 TYPE IL, CB 16 24" TO 36" 36" TYPE 11, CB 19 �48- BASIN� 36" TO 42" 42" TYPE 11, CB 19 54- BASIN **SOURCE: ASSOC. SAND AND GRAVEL CO. STDS. SCALE Dwr. NO. E5.12 REVISIONS STAN DAR D D ETAI L APPROV0 BY TABLE OF STANDARD RESIDENTIAL DETENTION SYSTEM S17-ES DATE lag()_, qc3o 7/24/01 NTS z 0 i 0 m 3: m c 0 m 0 --1 0 0 C M M z c: 3: 0 m m 0 0 m c: W 9 co M 0 Z X 3: z cl) z 0 i 0 m 17719 Ono d� - Dennis M. Bruce, RE. M.S.C.E., M.B.A. Geotechnical/ Civil Engineer April 28, 2004 RECEIVED MAY 2 4 2004 Michel Construction, Inc. i 7907212 th St. SW, #1 02 -4 IT COV PERMIT COUNTER Edmonds, WA 98026 C Subject: Geotechnicall Evaluation — Fou.ndation Recommendations Proposed 3 New Residences (7117 T-70i ?T�*,) 8717 Bowdoin Way, Edmonds, Washington This engineering report presents the results of a geotechnical evaluation of the Michel Construction, Inc. property at 8717 Bowdoin Way, Edmonds, Washington. This evaluation was required due to owner / developer concerns, as well as City of Edmonds requirements. REFERENCES: 0 Property Survey by LSA, Inc. 0 Proposed new 4-lot Site Plan by Michel Construction, Inc. 0 Photographs by D. Bruce, P.E. dated April 20, 2004 BACKGROUND: The overall property at 8717 Bowdoin Way is irregular in shape with approximately 50 feet of frontage along Bowdoin Way and approximately 270 feet deep. The rear property line is approximately 200 feet wide (see Survey and Site Plan). The property contains an existing residence (to remain) in what is now defined as Lot No. 1. Three new lots are defined and indicated on the Site Plan. Each of the 3 new lots will contain a proposed new single-family residence. The site contains portions of slopes exceeding.40 percent. Visual evaluation of the existing residence reveals no evidence of any geotechnical distress: no settlements, no foundation cracking, or any evidence of erosional degradation. SOILS - FOUNDATIONS - SITE DEVELOPMENT - INSPECTION - DRAINAGE - DESIGN & PERMIT - LEGAL P.O. Box 55502 - Shoreline, Washington 98155 - (206) 546-9217 - FAX 546-8442 z 0 1 0 M =i 9 M C M 0 -10 0 C --i C X M M z 10 --1 C -Z C') o -n n MM 055 0 r- 0 M C (n 9 C/) M 0 Z z --I X CD z 0 1 0 M Michel Construction, Inc. April 28, 2004 Page 2 The properties surrounding this site contain single-family and multi -family dwellings. EVALUATION: In order to augment the existing site geotechnical information, 3 soil test pits were dug under this engineer's observation on April 20, 20034 (1 test pit per proposed house location). See test pit layout plan. The findings of all 3 test pits revealed similar sub -grade conditions, namely: 0" to 8" Organics, roots, and organic silt 8" to 18" Reddish -brown sandy loam, grading to sandy silt. Dense 18" to 6' (bottom of test pits) Very dense, glacially consolidated sandy silt with gravels No water was encountered in any of the three test pits. All test pit walls remained vertical and stable. No sloughing or caving occurred. NOTE: Project developer (Michel Construction, Inc.) had partially cleared the site in order to perform test pit excavations. Additionally, the soil cut along the northeast portion of the slope provided excellent examination of the sub -grade soils (see photographs). The soil cut is approximately 8 feet in height and reveals extremely dense, glacially consolidated "hard pan" soils. The slope cut is stable and does not require shoring through the construction phase. It is understood that final grading will incorporate an erosion stabilization rockery on this exposed soil cut. CONCLUSIONS I RECOMMENDATIONS: Based on the findings of this investigation, and experience with similar sites in the area, the Michel Construction, Inc. property at 8717 Bowdoin Way, Edmonds, Washington is geotechnically approved for the proposed new three single-family residence development, subject to the following: Standard reinforced continuous and spread footings. Allowable bearing pressure: 2,000 p.s.f. Equivalent fluid pressure of 35 p.c.f. is recommended for any retaining wall design provided drainage zone is inspected and verified by this engineer. For retaining wall design, use friction factor of 0.55 and passive pressure of 350 p.c,f. Z 0 0 M =i:fi r M 0 0 0 0 C -19 X rn M Z nc --i C/) 0 71 n M M 0 0 0 M C/) 0 M 0 Z Z U) Z 0 1 0 M Michel Construction, Inc. April 28, 2004 Page 3 Geotechnical inspections by this engineer prior to any foundation concrete placement. The proposed structure can be supported on conventional continuous and spread footings bearing on undisturbed native soils or on structural fill placed above native soils. See the later sub -section entitled General Earthwork and Structural Fill for structural fill placement and compaction recommendations. Continuous and individual spread footings should have minimum widths of eighteen (18) and twenty-four (24) inches, respectively, and should be bottomed at least eighteen (18) inches below the lower adjacent finish ground surface. Depending on the final site grades, some over -excavation may be required below footings to expose competent native soils. Unless lean concrete is used to fill the over excavated hole, the width of the over -excavation at the bottom must be at least as wide as the sum of two times the depth of the over -excavation and the footing width. For example, an over -excavation extending two feet below the bottom of a three-foot wide footing must be at least seven feet wide at the base of the excavation. Footings constructed according to the above recommendations may be designed for an allowable soil bearing pressure of two thousand (2,000) pounds per square foot (p.s.f.). A one-third increase in this design bearing pressure may be used when considering short-term wind or seismic loads. For the above design criteria, it is anticipated that total post -construction settlement of footings founded on competent, native soils (or on structural fill up to five (5) feet in thickness) will be about one-half inch, with differential settlements on the order of one -quarter inch. NOTE: The bearing capacity of 3,000 p.s.f. applies to over -excavated and backfill conditions. Footings placed on native soils may be designed for 2,000 p.s.f. Lateral loads due to wind or seismic forces may be resisted by friction between the foundations and the bearing soils, or by passive earth pressure acting on the vertical, embedded portions of the foundations. For the latter condition, the foundations must either be poured directly against undisturbed soil or the backfill placed around the outside of the foundation must be level structural fill. We recommend the following design values be used for the foundation's resistance to lateral loading: Parameter Design Value Coefficient of Friction 0.55 Passive Earth Pressure 350 p.c.f. z 0 4 0 M -i -n �5 -4 0 M C M 0 0 __10 0 3: M M z cf) 0 _T1 n M M 061) 0 r- 0 M C C0 9(/) M 0 Z 3: z --i X W z 0 1 0 M 0 Michel Construction, Inc. April 28, 2004 Page 4 Where: (1) p.c.f. is pounds per cubic foot. (2) Passive earth pressure is computed using the equivalent fluid density. We recommend that a safety factor of at least 1.5 be used for design of the foundation's resistance to lateral loading. SLABS -ON -GRADE: Slab -on -grade floors may be supported on undisturbed, competent native soils or on structural fill. The slabs may be supported on the existing soils provided these soils can be re -compacted prior to placement of the free -draining sand or gravel underneath the slab. This sand and gravel layer should be a minimum of four (4) inches thick. We also recommend using a vapor barrier such as 6-mil. plastic membrane beneath the slab with minimum overlaps of 12 inches for sealing purposes. PERMANENT FOUNDATION AND RETAINING WALLS: Retaining walls backfilled on one side only should be designed to resist lateral earth pressures imposed by the soils retained by these structures. The following recommended design parameters are for walls less than twelve (12) feet in height, which restrain level backfill: Parameter Active Earth Pressure* Passive Earth Pressure Coefficient of Friction Soil Unit Weight Where: Design Value 35 p.c.f. 350 p.c.f. 0.55 125 p.c.f. (1) p.c.f. is pounds per cubic foot (2) Active and passive earth pressures are computed using equivalent fluid densities. For restrained walls which cannot defect at least 0.002 times the wall height, a uniform lateral pressure of one hundred (100 p.s.f. should be added to the active equivalent fluid pressure). z 0 1 0 M -1 OM C MO 0 --10 0 C 3: M M Z C') 0 -n n M M 0 0 0 M C: (j) 9 Cn M Z X z 3: 0) z 0 i 0 M Michel Construction, Inc. April 28, 2004 Page 5 The values given above are to be used for design of permanent foundation and retaining walls only. An appropriate safety factor should be applied when designing the walls. We recommend using a safety factor of at least 1.5 for overturning and sliding. The above design values do not include the effects of any hydrostatic pressures behind the walls and assume that no surcharge slopes or loads will be placed above the walls. If these conditions exist, then those pressures should be added to the above lateral pressures. Also, if sloping backfill is desired behind the walls, then we will need to be given the wall dimensions and slope of the backfill in order to provide the appropriate design earth pressures. Heavy construction equipment should not be operated behind retaining and foundation walls within a distance equal to the height of the wall, unless the walls are designed for the additional lateral pressures resulting from the equipment. Placement and compaction of retaining wall backfill should be accomplished with hand -operated equipment. Retaining Wall Backfill Backfill placed within eighteen (18) inches of any retaining or foundation walls should be free -draining structural fill containing no organics. This backfill should contain no more than five (5) percent silt or clay particles and have no particles greater than four (4) inches in diameter. The percentage of particles passing the No. 4 sieve should be between twenty-five (25) and seventy (70) percent. Due to their high silt content, if the native soils are used as backfill, a drainage composite, such as Mirafi and Enkadrain, should be placed against the retaining walls. The drainage composites should be hydraulically connected to the foundation drain system. The purpose of these backfill requirements is to assure that the design criteria for the retaining wall is not exceeded because of a build-up of hydrostatic pressure behind the wall. The subsection entitled General Earthwork and Structural Fill contains recommendations regarding placement and compaction of structural fill behind retaining and foundation walls. EXCAVATION AND SLOPES: In no case should excavation slopes be greater than the limits specified in local, state and national government safety regulations. Temporary cuts up to a height of four (4) feet deep in unsaturated soils may be vertical. For temporary cuts having a height greater than four (4) feet, the cut should have an inclination no steeper than 1:1 (Horizontal:Vertical) from the top of the slope to the bottom of the excavation. Under specific recommendations by the geotechnical engineer, excavation cuts may be modified for site conditions. All permanent cuts into native soils should be inclined no steeper than 2:1 (H:V). Fill slopes should not exceed 2H: 1 V. It is important to note that z 0 1 0 M =i 9 0 M C M 0 0 0 C: -4 F. MM M Z g:) --I C icn- o -n n M M 0 V5 0 r- 0 M C cl) 9 cn M 0 Z z C/) z 0 M Michel Construction, Inc. April 28, 2004 Page 6 sands do cave suddenly, and without warning. The contractors should be made aware of this potential hazard. NOTE: As discussed, this engineer approved and verified the stable slope cut at the northeast portion of the property. This cut reposes at an angle of 1 H:6V and is -geotechnically stable. This cut will be protected for erosional sloughing purposes during the final grading phase of the project. Water should not be allowed to flow uncontrolled over the top of any temporary or permanent slope. All permanently exposed slopes should be seeded with an appropriate species of vegetation to reduce erosion and improve stability of the surficial layer of soil. DRAINAGE CONSIDERATIONS: Footing drains are recommended at the base of all footings and retaining walls. These drains should be surrounded by at least six (6) inches of one -inch -minus washed rock wrapped in non -woven geotextile filter fabric (Mirafi 140N, Supac 4NP, or similar material). At the highest point, the perforated pipe invert should be at least as low as the bottom of the footing and it should be sloped for drainage. All roof and surface water drains must be kept separate from the foundation drain system. No groundwater was observed in any of the 3 test pits during the fieldwork. Seepage into the planned excavation is possible, and likely if excavation occurs during winter months, and if encountered should be drained away from the site by use of drainage ditches, perforated pipe, French drains, or by pumping from sumps interconnected by shallow connector trenches at the bottom of the excavation. The excavation of the site should be graded so that surface water is directed off the site and away from the tops of slopes. Water should not be allowed to stand in any area where foundations, slabs, or pavements are to be constructed. Any exposed slopes to be covered with plastic to minimize erosion. Final site grading in areas adjacent to buildings should be sloped at least two (2) percent away from the building, except where the area adjacent to the building is paved. GENERAL EARTHWORK AND STRUCTURAL FILL: The proposed building and pavement areas should be stripped and cleared of all surface vegetation, all organic matter, and other deleterious material. The stripped or removed materials should not be mixed with any materials to be used as structural fill. Structural fill is defined as any fill placed under the building, behind permanent retaining or foundation walls, or in other areas where the underlying soils needs to Z 0 1 0 M =i 9 C M M 0 0 0 0 C M M Z 0 -1 C 3: 0 -n Ti --I mg M M 0 0 0 M C cl) 9 cn Q 0 Z ;U Z --I 3: CO Z 0 i 0 M Michel Construction, Inc. April 28, 2004 Page 7 support loads. This engineer should observe site conditions during and after excavation prior to placement of any structural fill. All structural fill should be placed in horizontal lifts with a moisture content at or near the optimum moisture content. The optimum moisture content is that moisture content which results in the greatest compacted dry density. The moisture content of fill soils is very important and must be closely controlled during the filling and compaction process. The allowable thickness of the fill lift will depend on the material type, compaction equipment, and the number of passes made to compact the lift. In no case should the lifts exceed twelve (12) inches in loose thickness. The following table presents recommended relative compaction for structural fill: Location of Fill Placement Beneath footings, slabs or walkways Behind retaining walls Beneath pavements Minimum Relative Compaction 95% 90% 95% for upper 12 inches of Sub -grade, 90% below that level Where: Minimum relative compaction is the ratio, expressed in percentages, of the compacted dry density to the maximum dry density, as determined in accordance with ASTM Test Designation D-1557-78 (Modified Proctor). Use of On -Site Soils If grading activities take place during wet weather, or when the silty, on -site soils are wet, site preparation costs may be higher because of delays due to rains and the potential need to import granular fill. The on -site soils are generally silty and thus are moisture sensitive. Grading operations will be difficult when the moisture content of these soils exceeds the optimum moisture content. Moisture sensitive soils will also be susceptible to excessive softening and "pumping" from construction equipment traffic when the moisture content is greater than the optimum moisture content. Ideally, structural fill, which is to be placed in wet weather, should consist of a granular soil having no more than five (5) percent silt or clay particles. The percentage Z 9 0 M =i M M 0 0 0 0 C: ­4 K X M M Z g) --I C 0 M M 0 0 0 M C Cn K (n M 0 Z X Z C/) Z 0 1 0 M Michel Construction, Inc. April 28, 2004 Page 8 of particles passing the No. 200 sieve should be measured from that portion of the soil pan tng-th-eFth­r-ee--�u-9rt6r-i rfch-si eve. The use of "some" on -site soils for fill material may be acceptable if the upper organic materials are segregated and moisture contents are monitored by engineering inspection. DRAINAGE CONTROLS: No drainage problems were evident with the overall property at 8717 Bowdoin Way. Currently, surface water flows westerly and southwesterly. No evidence of erosional degradation was observed. Contractor shall utilize standard City of Edmonds erosion control measures during construction to minimize / prevent any siltation runoff. Permanent drainage shall comply with City of Edmonds Code and standard good practices. CONCRETE: All foundation concrete (footings, stem walls, slabs, any retaining walls, etc.) shall have a minimum cement content of 5-1/2 sacks per cubic yard of concrete mix. ROCKERIES: As discussed, the current stable slope cut at the eastern portion of the property will use an approximate 8-foot high rockery for erosion control purposes. Rockery construction shall comply to ARC Standards and this engineer's on -site inspections. INSPECTIONS: The recommendations of this report are only valid when key geotechnical aspects are inspected by this engineer durinq construction: • Soil cuts • Foundation sub -grade verification • Retaining wall, or rockery placement • Any fill placement • Subsurface drainage installation Z 0 I 0 M 0 0 0 C M M Z C 0 _n n M M 0 0 0 M C Cj) 9 V) Q 0 Z X Z __4 X C/) Z 0 i 0 M Michel Construction, Inc. April 28, 2004 Page 9 SUMMARY: The proposed Michel Construction 3 single-family residence development at 8717 Bowdoin Way, Edmonds, Washington is geotechnically viable when constructed in accordance with the recommendations herein, compliance with City of Edmonds approved plans and requirements, and key geotechnical inspections during construction. CLOSURE: The findings and recommendations of this report were prepared in accordance with generally accepted professional engineering principles and practice. No other warranty, either express or implied, is made. The conclusions are based on the results of the field exploration and interpolation of subsurface conditions between explored locations. If conditions are encountered during construction that appear to be different than those described in this report, this engineer should be notified to observe the situation and review and verify or modify the recommendations. If there are any questions, do not hesitate to call. EXPIRES DMB:abj ( �-00 A- 6L /�' 6�� Dennis M. Bruce, P.E. Geotechnical / Civil Engineer z 0 1 0 M ri C4 42b7789086 388 - - - - - - - - - - - - 400 LOT -402 404 ROM t.,A Us 40(1 9.301 408 410 4 EmsnN 418 4JU 422 424 1A 7,:r 42D ?17 428 430 432. 4,-�4 4uo VURTIC.Al QAT-L;m I -IN IN J�(�Aj� SITUISENCH MARX . MICHEL CONST PAGE e2 0 4,()ti 412 420 422 124 42.-, z z 0 1 0 m -1 -n M c m 0 0 0 0 M M Z c 3: CD 0 -n n m m 0 0 m c CD r. cn M 0 Z 3: z -4 3: cn z 0 m 0 Jul 23 04 UH:42a U. Bruce, P.h. 2ub-b46-H442 P.1 Dennis M. Bruce, P.E. M. S. C. E., M. B. A. Geotechnical /Civil Engineer July 22, 2004 City of Edmonds Community Services Division 121 5�h Ave. N. Edmonds, WA 98020 Subject: Geotechnical Inspections 8717 and 8719 Bowdoin Michel Construction 3 New Residences City of Edmonds Permit # 2004 — 0522 This engineering report presents the results of onsite geotechnical�� inspections for the Michel Construction project (1 existing residence plus 3 new s.f.r.) at 8717 Bowdoin, Edmonds. REFERENCES: City of Edmonds approved project plans Geotechnical Report by D. Bruce, P.E. Site photographs Cal) Required special inspections by City of Edmonds (geotechni INSPECT[ This engineer has provided onsite geotechnical inspections for the above project. Site visits occurred at a minimum of I inspection visit per week, with more frequent inspections during active excavation and grading activities. Excavations for this project began in April, 2004. See photographs. City of Edmonds Inspec tion Items: 1) Excavation and Grading: This engineer verified subsurface conditions consistent with the findings of the geotechnical report. The east property line excavation . is stable dense glacially consolidated "hardpan" soils at a slope approximately 1 H: 1 V. This slope cut is stable. Additionally, excavation and IqMporary access road fill occurred west of proposed house # 2 (see later discussion on slope stability). SOILS - FOUIVDA TIOIVS - SIrE DEVEL 01WENT - WSPECrION - DRAIIVA6E - DES16N & FERUIT - LEGAL P.O. BOX 55502 - Shoreline, WA 98155 - (206) 546-9217 Iq JtX-12P6 54JB-.qA C E i V E 6 J U L 2 3 2004 DEVELOPMENT SERVICES CTR. CITY OF EDMONDS 01 z 0 rn —i -T1 5S M 0 0 -40 0 M M Z r') --i C F- 3: W 0 -n n M M 055 0 r- 0 M C/) M 0 Z X z C0 z 0 1 0 M Jul 23 04 09:42a 11. Bruce, P.E. 206-546-8442 p.2 City of Edmonds July 22, 2004 Page 2 of 3 2) Soil Bearing: This engineer verified dense native sub -grade soils easily providing a minimum of 2.000 p.s.f. bearing capacity for the proposed house on lot 2 and lot 4. "OK' to proceed with foundation formwork, reinforcing steel placement, and concrete per City of Edmonds approved plans for house on lot 2 and lot 4. Z 0 Excavations for house # 3 have yet to occur. 3) Retaining Wall I Rockery Construction: A review of the project plans by M Civil Designer D. Breske, P.E. indicates a rockery of 1 to 6 feet in height west of house # 2. 0 Existing conditions indicate approximately 12 to 16 feet of height is M C 0 M 0 required for stabilization wall. 0 0 C It is unclear at this time if the access roadway will be significantly lowered M or if a significant stabilization wall will be required. This engineer is involved in M Z discu ssions and design work with Michel Construction and D. Breske, P.E., C > regarding this stabilization wall. If a new design is required, this engineer will provide appropriate 0 -n M submittals to City of Edmonds. 4) Pla 3ment of Fill and Compaction: None yet required. rn M 0 C—n 0 r- 0 M 5) Footing Drains: Not yet. C Cn 9 Cn Q 0 Z r- SAFETY: IT This engineer has advised Michel Construction to use extra caution and X diligence regarding the access road and "marginally stable" side cut near house # 2. See photographs. Z it is gssentiall that no heavy equipment be allowed to utilize this access CD road within 10 horizontal feet of top of cut. Z 0 Additionally, safety fencing is recommended along the top of slope for the M access drive. M � Jul 23 04 09:42a D. Bruce, P.E. 206-546-8442 City of Edmonds July 22, 2004 Page 3 of 3 SUMMARY Geotechnical inspections items are gppLovedl through the date of this report July 22, 2004. Access road dimensions and stability issues will require further geotechnical recommendations "OK' to place foundation stem walls on lot 2 and footings on lot # 4. 11,ispections ongoing tions, do not hesitate to call. If there are any ques WAR Al Dennis M. Bruce, P.E. NAL Geotechnical Civil Engineer DMB:jpb z 0 0 M CE Cn Dennis M. Bruce, P.E. M. S. C. E., M. B. A. Geotechnical /Civil Engineer September 23, 2004 ------------- City of Edmonds z Community, Services Division 121 5"' Ave. N M Edmonds, WA 98020 =n- Subject: Field Reports — Geotechnical Inspections Ui -1 M C 8717, 8719, 8721 Bowdoin, Edmonds, Washington M 0 0 Michel Construction 3 New Residences 0 This engineering report presents the results of ongoing geotechnical inspections M M z for the Michel Construction project (3 new residences and access ro ad) at the above C: z referenced addresses. REFERENCES: 0 -n 0 City of Edmonds approved Project Plans MM 71 0 Geotechnical and Inspection Reports by D. Bruce, P. E. 0- r 0 Site photographs 0 M MO INSPECTIONS: Z This engineer has provided and continues to provide on -site geotechnical X inspections for the 3 new Michel Construction residences. > z 8717 Bowdoin (Permit No. 2004 — 052 This engineer continues to monitor slope stability for the driveway adjacent this z 0 residence. Access road has remained stable through this date (September 23, 2004). ?5 M Foundation soils were previously verified to. provide a minimum of 2,000 p.s.f. bearing capacity. The residence foundations were properly placed in accordance with approved Plans. Approved fill material (free draining gravel with fine content less than 15 percent) was properly placed behind foundation stern walls under this engineer's inspections. ro ed Plans and Subsurface drainage properly placed in accordance with app v normal good practices. SOIL S FOUIVDArlolVS SITEDEVELOpI14EN7, INSpECI-10N DRA11VAGE - DESIGN& PERUI 7' - L EGA L P.O. Box 55502 Shoreline, WA 98155 (206) 546-9217 FAX (206) 546-8442 City of Edmonds Community Services Division Re: Michel Construction September 23, 2004 Page 2 It is understood that the road stabilization rockery will begin within the next 2 weeks. This engineer is to provide ongoing inspections. 8719 Bowdoin (Permit No. 2004 — 0560): This engineer verified dense, native sub -grade soils capable of providing 2,000 p.s.f. bearing capacity. Foundation concrete was properly placed in accordance with City of Edmonds approved Plans. The slope cut immediately east of 8719 Bowdoin has remained stable throughout the project. Recent rockery work (a two -tiered rockery) has been placed in accordance with approved Plans and this engineer's on -site inspections. Base rocks were properly -grade soils. Rock size, linkage, batter and drainage embedded in dense, native sub zone were properly placed. Additionally, this engineer observed proper placement of structural fill material as backfill against the stem walls. Subsurface drains were properly placed in accordance with approved Plans and good practices. Geotechnical work on 8719 Bowdoin is approved through this date (September 23,2004). 8721 Bowdoin (Permit No. 2004 — 0620): This engineer verified stable excavation in creating house footprint zone for this residence. All soil cuts remain stable in dense, native soils as anticipated. Soil bearing of 2,000 p.s.f. (at a minimum) was verified. "OK" to proceed with foundation footings and stem walls. Localized grading will require landscape stabilization rockeries (forthcoming with ongoing geotechnical inspections). SUMMARY: 0 Geotechnical work to date (September 23, 2004) on the above 3 residences is approved. 0 Geotechnical inspections are ongoing. Z 0 0 M --I -n M C M 0 0 0 C M M Z g) -1 C Z 0 71 n X M M 0 0 0 M C/) 0 Q 0 Z .4� ;U X Z X W Z 0 M