Loading...
20041059.pdf[PERMIT DATE RECEIVED/ 7 EXPIRES CITY OF EDMONDS PERMIT NUMBER JOB UITE/ArT! ADDRESS. mn r CONSTRUCTION PERMIT APPLICATION OWNER NAMEiNAME OF BUSINESS PLAT NAMEISUBDIVISION NO, LOT NO LID NO MAILING ADDRESS ui LID FEE S PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP TESCP Approved [3 RW Permit Required 0 '0: z -2-,? e3 Street Use Permit Required 13 0 CITY ZIP TELEPHONE EXISTING PROPOSED inspection Required 0 SiduAalk Required 0 7.7;e REQUIRED DEDICATION FT Underground Waing required [3 NAME METER SIZE LINE SIZE NO. OF FIXTURES PRV REQUIRED YESM NOM z U 0: LLJ LLI t= ADDRESS REMARKS OWNERiCONTRACTOR RESPONSIBLE FOR EROSION CONTROLIDRAINAGE LU z a z CITY ZIP _7ELEPHONE NAME CBL# DATE ENGINEERING REVIEWED BY ADDRESS It 0 U IC?2 15ox FIRE REVIEWED BY DATE W �Z- CITY ZIP TELEPHONEZ06--��4e; M 0 U VARIANCE OR CU SHORELINE OR ADBH INSPECTION REO'D SEPA COMPLETED EXEMPT STATE LICENSE NUMLStK tAt_11Kf%1 ILM LIM C CHECKED By 22A 13YES 13NO I CA# ZONE SIGN AREA HEIGHT PROPERTY TAX ACCOUNT PARCEL NO, WAIVER 13 ALLOWED PROPOSED ALLOWED OSED I PROP Uj STUDY 0 I NEW RESIDENTIAL PLUMBING I MECH ACOMPLIANCE LOT COVERAGE ALLOWED PROPOSED REQUIRED SETBACKS (FT.) FRONT SIDE REAR PROPOSED SETBACKS (FT.) FRONT LIRSIDE REAR COMMERCIAL OR ADDITION 1:1 z CHANGE OF USE MIXED USE REMODEL SIGN PARKING REQ'D PROVIDED LOTAREA PLANNING REVIEWED BY DATE El MULTIFAMILY I GRADING Ei FENCE REPAIR CYDS I X FT.) REMARKS DEMOLISH TANK OTHER GARAGE Ei RETAINING WALL E:] FIRE SPRINKLER FIREALARM z CARPORT ROCKERY (L (TYPE OF USE. BUSINESS OR ACTIVITY) EXPLAIN. Tr/ CONSTRUCTI CODE . OCCUPAN GROUP (n uj 0 NUMBER OF NUMBER OF DWELLING SPECIAL Il`TSPeCiI0'_N CONSULTANT OCCUPANT co 0 STORIES UNITS REQUIRED LOAD DESCRIBE WORK TO BE DONE REMARKS 0 9 GEOTECH REPORT BY T-7— s 6— STRUCTURAL DESIGN BY: VALUATION Description FEE Description FEE Plan Check State Surcharge HEAT SOURCE LOTSLOPE% VESTED DATE Building Permit City Surcharge 2 PLAN CHECK NO: Plumbing Base Fee Mechanical THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO Grading BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBIC DONMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. Engr. Review PERMIT APPLICATION: SEE ECDC 19.00.05(A)(5) Engr. Inspection pu PERMIT LIMIT: SEE ECDC 19.00.005(A)(6) SEE BACK OF PINK PERMIT FOR MORE INFORMATION (n 'APPLICANT, ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESSORS Fire Review Plan Chk. Deposit V) W IN INTEREST. AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE CITY OF _1 2 EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES. AND AGENTS FROM ANY AND Fire Inspection Receipt # < ALL CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE FROM THE Insp. Total Amt. Due DEEMED TO MODIFY. WAIVE OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE Landscape 01 NOR LIMIT IN ANY WAY THE CITY's ABILITY TO ENFORCE ANY ORDINANCE PROVISION.' x - Recording Fee . A Receipt il . . . . . . . I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THAT THE INFORMATION APPLICATION APPROVAL GIVEN IS CORRECT; AND THAT I AM THE OWNER, OR THE DULY AUTHORIZED AGENT OF This application is not a pernut until signed by the THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- CALL Building official or his/her Deputy and Feesare paid,and TION: AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED receipt is acknowledged it) space provided IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION I WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. OFF1 ALS SIGNA URE DAT SIGN,ATURE (OWNER AGENT.,k DATE SIGNED (425) /A 771-0220 R - E S By DATP( -7— vATTENTION EXT. 1333 IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTI- ORIGINAL FILE YELLOW INSPECTOR FICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109 / IBC110 / IRC110. PINK -OWNER GOLD - ASSESSOR 10104 PRESS HARD - YOU ARE MAKING 4 COPIES 10 z 0 i 0 M --I -n CD M C M 0 0 0 C: --i K X M M Z 10--i C CD o -n n MM 0 0 0 M (= U) 90 M 0 Z z __q x cf) z 0 1 0 M Grease Trap Sizing Worksheet Facility Name: NC) I- 6h /7 / , __CLAn,_& j_ta, (A rn r, Address: 22ff Jq 100t, Ave'. Suite No.: • A Grease Trap plumbing permit is required ($165.00 fee). Contact the Pretreatment Technician (425-672-5755) if you have any questions and also to get signature approval on this form. • Dishwashers are not allowed to be connected to a Grease Trap. • Food disposers are not allowed in a facility served by a Grease Trap and must be disabled or removed. Solids must be screened out and placed in the solid waste container. — Fixture Capacity in Cubic Inches (L x W x 1) x no. of sinks)— Fixture Capacity in Gallons (Cu. In. + 231) Drainage Load (75% of Total Capacity) Flow Rate for a 2-Minute Drain Period #1 prexw a� h XY1 rj<, + 231 = gal. x.75 = gal. - 2 0 gpni #2 ck-o- x c.i. -.- 231 = gat. x .75 = gal. --.2= /0 gprn #3 x X X c.i. -- 231 = gal. x .75 = gal. 2= gpm #4 x x x c.i. + 231 = gal. , x.75 = gal. 2 gpm Grease Trap #1 - Total drainage flows from maximum of 4 fixtures gpin #1 x x X c.i. 231 = __gal. x.75= i!al. 2 gpm. #2 X x x c. 23 1. = gal. x.75 = __Kal- 2 # x x x c.i. 231 = gal. x .75 = ga 1. 2= gpm 1 �3 #4] x x x c.i. I + 231 = gal. x.75 = gal. 2 Grease Trap #2 - Total drainage flows from maximum of 4 fixtures gpm MINIMUM SIZE OF GRE ASE TRAP(S) RE QUIRED gp Number of Fixtures Connected to a Grease Trap 1 2 -3 4 Grease Trap Size (in gpm) 20 25 35 50 Upsize for factors such as high volume dishwashing, high oil/grease content on tnenu, etc. ----------- ---------------------------- (F or City use only below this line) ----------------------------------------------- VPVY) ;_t Remarks: DLAk-- -Lo Zibz, re -ELL QL00 2-2 IL Size Approved: 2-0 gpm Approved by: qZjjL4 - � Date: 12-j 7- 0 Pretreatu I iefi7e-elinician [Rev. Feb. 2W41 Z 0 A 0 M -1 -n 0 rn C M 0 0 0 C M M Z X Cn o -n n M M 05 0 r- 0 M C C/) 9 W M 0 Z ;U -4 r Z W Z 0 1 0 M FINAL PROJECT APPROVAL FORM RECEIVED TO: JA'N� '�.' 4 20,35 DATE: ENGINEERING DIVISION MEMO TO: PERMIT COORDINATOR, BUILDING DIVISION FROM: PRETREATMENT DATE- 3 PLEASE SI ENGINEERING DIVISION DATE_� PULASE SIGN PLANNING DIVISION DATE__� I'LEASE SIGN PROJEC 0, SITE ADDRESS__2.Ln4 /Oql� Ave�. PERMIT # 2-0014 - /059 ADB#---------PATF, INSPECTED--L2-----ZO----(D-�-'i-- DESCRIPTION OF WORK TO BE INSPECTED 1mlin 110-tiOn Of C' 20 - Lran A field inspection was conducted to determine compliance with -approved plans. Final approval denotes that there are no objections from the above signed Department to the release of PERFORAlANCE BONDS and the granting of -GRANT FINAL PROJECT APPROVAL GRANT PROJECT APPROVAL WITH CONDITIONS NOTED 0 Copy of CONDITIONS given to owner/contractor by inspector FAILED FINAL INSPECTION - OUTSTANDING ISSUES 0 Copy of CORRECTION NOTICE given to owner/contractor by inpector 2. 3. RE -INSPECTED OUTSTANDING ISSUES - GRANT FINAL PROJECT APPROVAL Date Signature 1:temp:b1dg:fomis:ocaprv1 3/25/04 z 0 M --i -n M C M 0 0 0 0 C: —1 K X M M Z JD --I C= cl) 0-71 n X > M M 0 6 0 r- 0 M C Cl) 9 U) I M C-) Z 71 X —i M > z C/) z 0 i 5 M RECORD OF INSPECTIONS INSPECTOR DATE APPROVED SETBACKS ..................... FOUNDATION: Footing...................... Wall.......................... Pier/Porch ................. Retaining Wall ........... Slab Insulation .......... PLUMBING: Underground ............. Rough -in ................... Commercial Final ...... HEATING, Gas Test .................... Gas Piping ................. Equipment ................. Commercial Final ....... EXTERIOR SHEATHING NAILING.......................... FRAMING........................ FIRST FLOOR FRAMING... INSULATION ................... Floor Insulation ......... Wall Insulation ........... Ceiling Insulation ....... SHEETROCK NAILING ... SPECIAL INSPECTION ... MISCELLANEOUS .......... FINAL APPROVAL FOR OCCUPANCY .................. j/ z 0 1 0 IT!