20050707.pdfif r DATE �RECEIVED CITY OF EDMONDS CONSTRUCTION PERMIT APPLICATION OWNER NAMEINAME OF BUSINESS V —a <,e r MAILING ADDRESS 2 'Ig� /� V-42- CITY ZIP TELEPHONE L102 774 / 7-&-_�33 NAME ADDRESS CITY zi I P —]TELEPHONE NAME 5 i� CBL# t�OAIE / *'Z-F - I ADDRESS CITY STATE LICENSE NUMBER TELEPHONE Lu _j PROPER7 Y TAX ACCOUNT PARCEL NO. q 600�onr QA-,l __2 NEW FRI RESIDENTIAL ADDITION COMMERCIAL MIXED USE REMODEL MULTIFAMILY GRADING REPAIR CYDS DEMOLISH TANK GARAGE RETAINING WALL z CARPORT ROCKERY )� 01 P1 n (TYPE OF USE, BUSINESS 9�ACTIYITY) EXPPIN:. — - - - DATE PERMIT EXPIRESSfl I PERMIT NUMBER ro 7 JOB SUITEIAPTO ADDRESS 02,10 C72 4' A PLAT NAMEISUBDIViSION NO LOT NO. LID NO LID FEE $ PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP TESCPApproved 13 RW Permit Reutufud 0 Strew Use Pernin Required 13. EXISTING PROPOSED Inspection Required E3 Sidewalk Required REQUIRED DEDICATION FT underground 13 Wiring required E3 METER SIZE LINE SIZE NO� OF FIXTURES PRV REQUIRED YES13 NOO z 0— rx REMARKS W W OWNER/CONTRACTOR RESPONSIBLE FOR EROSION CONTROUDRAINAGE z uj CHECKED BY PLUMBING / MECH COMPLIANCE OR CHANGE OF USE SIGN FENCE ( — X FT.) OTHER FIRE SPRINKLER FIRE ALARM EERING REVIEWED N A 12-10 FIRE REVIEWED BY It DATE VARIANcr OR CU SHORELINE RADB# INSPECTIO SEPA REO'D I COMPLETED EXEMPT 13YES N NOI I X CA# ZONE SIGN AREA HEIGHT WAIVER 13. ALLOWED PROPOSED ALLOWED PROPOSED I S STUDY , LOT COVERAGE REQUIRED SETBACKS (FT) PROPOSED SETBACKS (FT.) ALLOWED PROPOSED FRONT SIDE REAR FRONT UR SIDg REAR C2 CD I W �z PARKING LOTAREA PLANNING REVIEWED BY DATE z REO'D PROVIDED 1 `ZD31f'(� I 15 1- 19 AA A)IxA,�A ,.- 0 �</ n 2,/ n i.;; fie�&s I ctot 17 lext M TYPE OJUUCTION C NUMBER OF STORIES �hzs-e m-ent NUMBER OF DWELLING I UNITS jMe SPECIAL INSPkTION RE U RED YES CRIBE,WnRK Tn RP As I�MDU., w— 1-111imc: n CRAX, rdlell q6l 77r —7 4200 C_01 I LL;RVIN& 7 M S REMARKS! \L61 OF6M v 8VA-N�> ",f GEOTECHREPORT BY: ME M M 'T V11 4NU P.00O 9 VALUATION $ ��, 9K) O"b�6 102-1 t� �LWI,!� 10'r-, ;;?.% I 1011 .18 1 F 111-0121H 52-7 t# Description Plan Check HEAT SOURCE/ 6 LOT SLOPE% VESTED DATE Building Permit C1 Ci -a - 3 1 - ni q OCCUPANT GROUP T ?� I I R T CONSUL PLAN CHECK NO: 121 -- - , C) ;_;> 5 Plumbing 04� . C-) 1 THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO Mechanical BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBIC DONMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE Grading SEPARATE PERMISSION. PERMIT APPLICATION: SEE ECDC 19.00.005(A)(5) Engr. Review PERMIT LIMIT. SEE ECDC 19.00.005(A)(6) SEE BACK OF PINK PERMIT FOR MORE INFORMATION Engr. Inspection L 'APPLICANT, ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESSORS Fire Review IN INTEREST, AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE CITY OF EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM ANY AND Fire Inspection ALL CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL. NOT BE DEEMED TO MODIFY, WAIVE OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE Landscapelnsp. NOR LIMIT IN ANY WAY THE CITY'S ABILITY TO ENFORCE ANY ORDINANCE PROVISION. - Recording Fee I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THAT THE INFORMATION GIVEN IS CORRECT; AND THAT I AM THE OWNER, OR THE DULY AUTHORIZED AGENT OF THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- TION; AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED CALL IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. SIGNATUR( DATE SIG7,ED (425) 6 1 &./ C le� 7 771-0220 ATTENTION EXT. 1333 IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTI- FICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109 / IBC110 if IRC110. OCCUPANT LOAD FEE Description I Q State Surcharge 49-3c) City Surcharge 17411 1 Base Fee FEE Plan Chk. Deposit Receipt # X Total Amt. Due .?� 10 ,Receipt# APPLICATION APPROVAL This application is not a permit until signed by the Building Official or tits/her Deputy and Fees are paid, and receipt is acknowledged in space provided IALS SIGN )RE DATE 10104 PRESS HARD - YOU ARE MAKING 4 COPIES INAL - FIL.1 K -INSPECTOR ASSESSOR C z r � z 0 1 0 M --I _n C/j M C M -jo 0 oc� Im X M M Z 10 C X 0) 0 -n n x M M 0 0 0 M C (1) 9 Cn Q 0 Z X z C/) z 0 1 0 M 4022 sf Old Roof OverhWQ- — I FOR INSPEUTIUM I 4"7 sf New Roof Ov -1 =91 . I . . . . . Benchmark (smaller are . I cc n� PCO AO Top of Mom EL-36M WR 18B. 0 N09542BW ExIsUng Saw Ikv - ------- S-UVFACF--S 10 1 k A�L .5 *We* - 7"' / -�B!3�0,7. 'I 2v Existing D BE "QOVLF �E-D! LT41 N— 2- DAYS rivieway CD Bda�l' Bk Rii ffr Lee— —t-� - — — — — — T N893428-W iiB.17 2Q1,376 Sf ACCEPTAB�E- -TIGH I LINE 01 MATER& 4- \ ' /-\ N' Y I in SDR 35 CD ID Cg CS z SCH 40 \J C- N6W Ac d area I I < IM I (D N-12 > 0 F810 HANCQR C9 .2= sf C4 6� Ro(�ker I sf M LO *% House 1021 CD W A c M Bidsting .9 Fir Gai- "12395 -Sf 87, 0' C14 U R 4WO 1 72x4O .2 L < > —.1 1 LO (D CL WR .9 rCL .L %1FI&- 12) O'j*j'§pObTj NesSS48W CIO :.q -0 "Ir - I j > �EGTl TO I SYM Vj L . it LLI 0 It W Zone I- ComerND-Flag .5 W F=- (D S etbacks Required Actual Is LU ca CD t > W- Aettr E i DI cy) '27190 It St Hei wit /1-9395 Sf titi MD.' E LL 4— LL N, NOM or C3 W Cornerstone 17625-130th Ave. NE, C102, Woodinville, WA 98072 Phone: 425-8"-1977 Geotechnical, Inc. Fax: 425-844-1987 July 13, 2005 Mr. Jeff Mietzner z 20210 - 92n' West 0 Edmonds, Washington 98020 M Geotechnical Report Single -Family Residence X. M. Edmonds, Washington ..0 M CG File No. 1913 .80 0 C 3: W. Dear Mr. Mietzner: mz� INTRODUCTION C z > This report presents the results.of our geotechnical evaluation for your single -family residence Ca nd site plan located at 20210 - 92 West in Edmonds, Washington., We have been provided with a 0 _n. showing existing topography and planned residence location. You have requested that we M M provide this report that addresses the bearing capacity for the existing foundation system. �.0 0 Fn. C Ca ic Cf) We understand that you plan to remodel the existing residence and use the existing. foundation M O� Z r-:, system.. The existing house is a single-efamily residence with a daylight basement and was constructed in approximately the 1950's. Concrete basement walls exist on the north, east and south sides of the residence. We have not been provided with plans of the new remodel. We Z? understand that the existing remodel will require a bearing capacity of at least 3,364 pounds per -A square foot. z 0� 0 M -SCOPE The purpose of our services was to evaluate -site conditions and to provide recommendations for development. Our scope of services included the following: 1. Review available geologic maps for the site area. 2. Evaluate the subsurface conditions in holes adjacent to the daylight basement. Geotechnical Report Mietzner Single -Family Residence Edmonds, Washington July 13, 2005 CG File No. 1913 Page 2 3. Provide recommendations for foundation support. 4. Document our findings, observations, and conclusions in a report. SITE CONDITIONS z Surface Conditions 0 d The site is rectangular with an access driveway that extends east towards 92 Avenue West. The site is approximately 179 feet in the east to west direction and approximately 100 feet in the north C4 X C: to south direction. M 0 0 0 C The site slo es gently down to the west before reaching the top of a steep slope. Based on the p M provide d site plan, there is a vertical relief of approximately 14 feet from the east to west property M z lines. The steep slope is located off the property to the west and it is approximately 90 feet from C > the residence based on the site plan. The.steep slope extends down to the adjacent residence to r ca the west. 0 _n _n M The existing foundation appears to be performing adequately with no noticeable signs of cracks. M ettled behind the basement r We observed some areas where the backfill appears to have s etaining 0 0 M C CD walls and caused distress in the surrounding sidewalks. E co M 0 z r Geology Most of the Puget Sound Region was affected by past intrusion of continental glaciation. The last > period of glaciation, the Vashon Stade of the Fraser Glaciation, ended approximately 10,000 to' z 11,000 years ago. Many of the geomorphic features seen today are a result of scouring and overriding by glacial ice. During the Vashon Stade, the Puget Sound region was overridden by z 0 over 3,000 feet of ice. Soil layers overridden by the ice sheet were compacted to a much greater M extent than those that Were not. The geology of the site is shown on the Preliminary Surficial Geologic Map of the Edmonds East and Ed monds West Quadrangle, Snohomish and King Counties, Washington, Mackey Smith, 1975. The geologic unit mapped in the project is Vashon Glacial Till. The glacial till consists of a dense, non -sorted mixture of clay, silt, sand and gravel. We encountered sand deposits that appear to be advancebutwash and glacial drift. Advance outwash was a geologic unit that was Cornerstone Geotechnical, Inc. Ge'otechnical Report, Mietzner Single -Family Residence Edmonds, Washington July 13, 2005 CG File No. 1913 Page 3 deposited during the melt waters as the gl acier advanced over the area. Therefore, the outwash has been compacted by the weight of the glacier. Glacial drift is similar to glacial till, but has some sand seems and may not be as dense. Z Explorations 0 Subsurface conditions were explored at the site on July 5, 2005, by excavating a total of two holes with a hand auger. The explorations were excavated to depths of approximately 1.5 feet n. below the ground surface. The explorations'were located in the field by a representative from this 11A M C firm who also examined the soils and geologic conditions encountered, and maintained logs of 0. the hand augers. The approximate locations of the explorations are shown on the Site Plan in 0 C Figure 2. The soils were visually classified in general accordance with the Unified Soil M M Z Classification System, a copy of which is presented as Figure 3. The logs of the explorations are presented in Figure 4. CO Subsurface Conditions 0 _n -n We encountered gray -brown, dense to very dense, fine to medium sand in Hand Auger 1 (HA-1) M M underlying the surface fill. We have interpreted these soils to be advance outwash. The footing 0 0 r 0 M for- the e xisting residence is, sup orted by the advance outwash. The footing appears to be a p C (A M CO conventional footing with a width of 16 inches. �Mo Z r- We encountered gray -brown, silty sand to.sand with silt in HA-2 underlying the surface fill. We 3: have interpreted these soils to be advance outwash or glacial drift. We where unable to evaluate Z the width and depth of the footing in this area, but we expect the foundation systemis supp orted Cn on the advance outwash or glacial drift. Z 0 Hydrologic Conditions 0 M Shallow ground water seepage was not encountered in our explorations. During the wetter times of the year, we expect perched water conditions may. occur within the upper sand on top of the low permeable soil layers. Perched water does not represent a regional ground water "table" within the upper soil horizons. Volumes of perched ground water vary depending upon the time, of year and the upslope recharge conditions. :Cornerstone Geotechnical, Inc. I V Geotechnical Report Mietzner Single -Family Residence Edmonds, � Washington July 13, 2005 CG File No. 1913 Page 4 Seismic Hazard The site is classified based on its overall soil profile using Table 1615.1.1 of the 2003 International Building Code, (IBC). Site conditions best fit the IBC definition for Site Class C 0 ("Very dense soil and soft rock"). The IBC provides parameters and coefficients to be used in seismic design based upon this site class. 49 Additional seismic considerations include liquefaction potential and amplification of ground C4 X -0 rn C motions by soft soil deposits. The liquefaction potential is highest for loose sand with a high M 0 ground water table. The underlying dense soils are considered to have a very low potential for 0 C liquefaction and amplification of ground motion. M M Z F- -4 SLOPE STABILITY 3: CA The core of the site is inferred to be comprised of advance outwash. We did not observe signs of 0 _n deep-seated slope failures.. The existing structure has -an adequate. setback from the steep slope. M M and does not pose a.significant stability concern. 0 r- 0 M cl) ca CONCLUSIONS AND RECOMMENDATIONS M01 General It is our opinion that the site is compatible with the planned development. The underlying dense or better soils are capable of providing adequate support for the remodeled structure. It is our opinion the existing residence has large setback from,tbe steep slope and it is acceptable. CD 0 We did not observe any noticeable distress from settlement of the existing structure. We expect the any future settlement, even with the slightly additional loads, will not be significant enough to M cause more than cosmetic cracking. Foundations We are not aware of new foundations, but if some are. needed, we recommend they be completed in accordance with this section. Conventional shallow spread foundations should be founded on undisturbed, medium dense to very dense, advance outwash, or be supported on structural fill extending to those soils. If the soil at the planned bottom of footing elevation is not medium dense to very dense, it should be overexcavated to expose suitable bearing soil, and the Cornerstone Geotechnical, Inc. Geotechnical Report Mietzner Single -Family Residence Edmonds, Washington July 13, 2005 CG File No. 1913 Page 5 excavation should be filled with structural fill, or the footing may be overpoured with extra concrete. Footings should extend at least 18 inches below the lowest adjacent finished ground surface for 0, frost protection and b ty considerations. Minimum foundation widths of 16 and 20 earing capaci inches should be used for continuous and isolated spread footings, respectively. Standing water �should not be allowed to accumulate in footing trenches.' All loose or disturbed soil should be M removed from the foundation excavation prior to placing concrete. M 0 For foundations constructed as outlined above, we recommend an allowable design bearing M, pressure of 3,500 pounds per square foot (pso can be used for the footing design. International M Z' Building Code (MC) guidelines should be foll owed when considering short-term transitory wind or seismic loads. Potential foundation settlement using the recommended allowable bearing M, pressure ween footings or is estimated to be less than 1-inch total and V2-inch differential bet 0 -n -n across a distance of about 30 feet. We should be retained to evaluate any new fboting,E2hgades M M prior to placing concrete. 0 M. Cn Lateral loads can be resisted by friction between the foundation and subgrade soil', and by passive C/) Q soil resistance acting on the below grade portion of the foundation. For the latter, the foundation Z r must be poured "neat" against undisturbed soil or backfilled with clean free -draining, compacted structur al fill. Passive resistance may be calculated as a triangular eq alent fluid pressure distribution. We recommend that an equivalent fluid density of 225 pounds.per cubic foot (pcf) be used to calculate the allowable lateral passive resistance for the case of a level ground surface CO' z adjacent to the footing. An allowable coefficient of friction between footings and soil of 0.45 0 may be used, and should be applied to the vertical dead load only.. A factor of safety of 2.0 has rri been applied to the paissive pressure to account for required movements to generate these pres . sures. The friction coefficient does not include a factor of safety. Drainage rom impervious surfaces, such as rooifs, driveway and access We recommend that runoff f roadways, be collected and routed to an appropriate storm water discharge system. Final site grades should allow for drainage away from any buildings. We suggest that the finished ground Cornerstone Geotechnical, Inc. Geotechnical Report Mietzner Single -Family Residence Edmonds, Washington July 13, 2005 CG File No. 1913 Page 6 surface be sloped at a gradient of 3 percent minimum for a distance of at least 10 feet away from the buildings as specified in the I13C. z 0. USE OF THIS REPORT We have prepared this report for Mr. Jeff Mietzner and his agents, for use in planning and design of this project. Within the limitations of scope, schedule and budget for bur work,, we have strived to take care our work has been completed in accordance with generally accepted practice s CD M, M C I Ai followed in this area at the time this report was prepared. No other conditions, expressed or M 0 implied, should be understood. 0. 0 a X m mz� We appreciate the opportunity to be of service to you. If there are any questions concerning this letter or if we can provide additional services, please call. Sincerely, 0 -n -n Cornerstone Geo'technical, Inc. M M 0 M. 0 0M C M O� z — r AS Z' 0530 3: z 0 M, Rick B.'Powell, PE Principal RBP:nt Three Copies Submitted Four Figures a Engi eering Report Information about this Geotechnic I n Cornerstone Geotechnical, Inc. 20, 5 (V SPRAGUE H LU 2D6T -4 OTrH BE 2 208TH D "0 1.209TH MAPLEJ ALDER *AL 71L, 6 1 0 121 'H 0 JwF CEDAR HO LL > "S-"P,- -R, UCE 213T 41 214TH NT LAURELr --- po V) Ivi HEM 0!�K Sii� Mo PINE r @11995 Thomas Bros. Maps Phone: (425) 844-1977 Mietzer Residence cornerstone Fax: (425) 844-1987 Geotechnical, Inc. File Number Figure 17625-130th Ave NE, C-1 02 Woodinville, WA 98072 1913 1 M Site Plan R-Jv Leciend HP-1 Hand pit number and approximate location Not to scale 0�9 Unified Soil Classification System MAJOR DIVISIONS GROUP SYMBOL GROUPNAME GRAVEL CLEAN GRAVEL GW WELL -GRADED GRAVEL, FINE TO COARSE GRAVEL COARSE - GRAINED MORE THAN 50% OF GP POORLY-GkADED GRAVEL COARSE FRACTION GRAVEL WITH FINES GM SILTY GRAVEL SOILS RETAINED ON NO. 4 SIEVE GC CLAYEY GRAVEL MORETHAN50% RETAINED ON number 2 00 SIEVE SAND CLEAN SAND SW WELL -GRADED SAND, FINE TO COARSE SAND SID POORLY -GRADED SAND MORE THAN 50% OF SAND WITH FINES SM SILTY SAND COARSE FRACTION PASSES NO. 4. SIEVE SC CLAYEY SAND SILTAND CLAY INORGANIC ML SILT, FINE - GRAINED LIQUID LIMIT LESS THAN 50% CL CLAY ORGANIC OL ORGANIC SI LT, ORGANIC CLAY SOILS MORETHAN50% PASSES NO. 200 SIEVE SILT AND CLAY INORGANIC MH SILT OF HIGH PLASTICITY, ELASTIC SILT CH CLAY OF HIGH PLASTICITY, FAT CLAY LIQUID LIMIT 50% OR MORE ORGANIC OH ORGANIC CLAY, ORGANIC SILT HIGHLY ORGANIC SOILS PT PEAT NOTES: SOILMOISTURE MODIFIERS 1) Field classi fication is based on Dry- Absence of moisture, dusty, dry visual examination of soil in general to the touch accordance with ASTM D 2488-83. Moist- Damp, but no visible water 2) Soil classification using laboratory tests is based on ASTM D 2487-83. Wet- Visible free water or saturated, Usually Soil is obtained from 3) Descriptions of soil density or below water table consistency are based on interpretation of blowcount data, visual appearance of soils, and/or test data. Cornerst one Phone: (425) 844-1977 Unified Soil Classification. System Fax: (425) 844-1987 Geotechnical, Inc. IV 17625-130th Ave NE, C'l 02 - Woodinville, WAO 98072 Figure 3 z 0 m =i 9 am 0 0, 0 M .mz 0 -n. n M M q 0 0'm C 0) M 0 Z Zr X z 0 m .......... LOG OF EXPLORATION DEPTH Usc SOIL DESCRIPTION HAND AUGER ONE 0.0-1.0 sm BROWN, SILTY SAND WITH GRAVEL (MEDIUM DENSE, MOIST) (ELLL) SP. GRAY -BROWN, FINE TO MEDIUM SAND (DENSE TO VERY DENSE, MOIST) (ADVANCE OUTWASH) GROUND WATER SEEPAGE WAS NOT ENCOUNTERED Z, CAVING WAS NOT ENCOUNTERED HAND AUGER WAS COMPLETED AT 1.5 FEET ON 7/05�05 FOOTING WIDTH is APPROXIMATELY 16 INCHES AND IS PART OF A LARGE STEM WALL FOR THE DAYLIGHT BASEMENT HAND AUGER TWO CA 0.0-1.0 sm BROWN, SILTY SAND WITH GRAVEL (LOOSE TO MEDIUM DENSE, MOIST) (ELL-Lj x a m c 1.0-1.5. SM/SP-SM GRAY -BROWN, SILTY SAND TO SAND WITH SILT (DENSE TO VERY DENSE, MOIST) m Ol (ADVANCE OUTWASH/DRIFT) 0 O'� GROUND WATER SEEPAGE WAS NOT ENCOUNTERED. C:'' 3: M CAVING WAS NOT ENCOUNTERED z HAND AUGER WAS COMPLETED AT 1.5 FEET ON 7/05/05 10 z cn 0 -n :m m 0 m C (jj� lz 0 Z O� M, CORNERSTONE GEOTECHNICAL, INCI FILE NO 1913 FIGURE 4 IMPOMM. OPMR000 AboOt. Youll Z 0 The foll6winginformalion isprovidedtohe) you,mnoge your risks. 0 M C5 M C Geotechnical Sepvices Ape Pepfopmed fop elevation, configuration, location, orientation, or weight of the M 0 Specific Pupposes, Pepsons, a nd PpoJects proposed structure, 80 C Geotechnical engineers structure their services to meet the specific needs of composition of the design team, or C :1. 1 M their clients. A geotechnical engineering study conducted for a civil engi- project ownership. M Z neer may not fulfill the needs of a construction contractor or even another civil engineer. Because each geotechnical engineering study is unique, each As a general rule, always inform your geotech.nical eng ineer of project geotechnical engineering report is unique, prepared solely for the client. No changes —even minor ones —and request an assessment of their impact. one except you should rely on your geotechnical engineering report without Geotechpidal engineers cannot accept responsibility or liability for problems first conferring with the geotechnical engineer who prepared it. And no one that occur because their reports do not consider developments, of which 0 -n -n not even you — should apply the report for any purpose or project they were not informed. except the one.originally contemplated. Subsupf ace Conditions Can Change M M 0 V5 Read the Full Repopt A geotechnical engineering report is based on conditions that existed at 0 r_ O,M Serious problems have occurred because those relying o n a geotechnical the time the study*was performed. Do not rely on a geotechnical engineer- C cl) M co engineering report did not read it all. Do not rely on an executive summary. ing-report whose adequacy may have been affected by: the passage of M 0 Do not read selected elements only. time; by man -made events, such as construction on or adjacent to the site; fluctua- Z r— T . or by natural events, such as floods, earthquakes, or groundwater A Geotechnical Engineeping Repopt Is Based on tions. Always contact the geotechnical engineer before applying the report X A Unique Set of PpoJect-Specific Factops to determine if it is still reliable. A minor amount of additional testing or Gootechnical engineers consider a number of unique, project -specific fac7 analysis could, prevent major problems. Z tors when establishing the scope of a study. Typical factors include: the client's goals, objectives, and risk management preferences; the general Most Geotechnical Findings Ape Ppolessional 6i nature of the structure involved, its size, and configuration; the location of the structure on the site; and other planned or existing site improvements, Opinions Site exploration identifies subsurface conditions only at those points where Z 01 -1 such as access roads, parking lots, and underground utilities. Unless the subsurface tests are conducted or samples are taken. Geotechnical engi- 0 geotechni . cal engineer who conducted the study specifically indicates oth- neers review field and laboratory data and then apply their professional M erwise, do not rely on a geolechnical engineering report that was: judgment to render an opinion about subsurface conditions throughout the 0 not prepared for you, site. Actual subsurface conditions may differ —sometimes signitica.ntly. 0 not prepared for your project, from those indicated in your report. Retaining the geolechnical engineer a not prepared for the specific site explored, or who developed your report to provide construction observation is the 0 completed before important project changes were made. most effective method of managing the risks associated w ith unanticipated conditions. Typical changes that can erode the reliability of an existing geotechnical A Repopt's Recommendations Ape Not Final engineering report include those that affect: the function of the proposed structure, as when it's changed from a Do not overrely on the construction recommendations included in your parking garage to an office building, or from a light industrial plant report. Those recommendations are not final, because geotechnical angi- to a -refrigerated warehouse, neers develop them principally from judgment and opinion. Geotechnical engineers can finalize their recommendations only by observing actual ASFE The Best People on Earth 8811 Colesville Road/Suite G106, Silver Spring, MID 20910 Telephone: 301/565-2733 Facsimile: 301/589-2017 e-mail: into@aste.org wwaste.oig Copyright 2004 by ASFE, Inc. Duplication, reproduction, or copying of this document, in whole or in part, by any means whatsoever, is strictly prohibited, except with ASFE's specific written permission. Excerpting, quoting, or otherwise eKtracting wording from this document is permitted only with the express written permission ofASFE, and only for purposes of scholarly research or book review. Only members of ASFE may use this'doCUMMI is a complement to or as an element Of a g0t6chnicaf engineering report. Any other firm, Individual, or other entity that so uses this document without being an ASFE member could be committing negligent or intentional (fraudulent) misrepresentation. IIGER06045.OM CASCADE TESTING LABORATORY, INC. & INSPECTION PREVIOUS 2 17 TESTING REPORT No. No. 12919 N.E. 126TH PLACE KIRKLAND, WASHINGTON 98034 (425) 823-9800 EVERETT (425) 259-OE117 DATE CERT. NO. CIRT FIELD REDC01 PROJECT LOCATION TO: BLDG. PERMIT NO. OWNER TEMP.- AT AM WEATHER 0./7,/Z 7- L2�; AT PM ENGINEER ARCHITECT ATTN: CONTRACTOR (2) INSPECTION PERFORMED FOUNDATIONS co M. c 0 (3) ITEMS INSPECTED RESTEELICONCRETE RESTEELONLY FOOTINGS. SLAB.— M 0 0 0 C RESTEEUMASONRY STR.ST/WELDING AUGER CAST PILES COLUMNS ­4 C m OTHER STR.ST/BOLTING DRILLED PIERS WALLS. rn z BEAMS c: z (4) //04 0 71 LOCAT ION (AREAS) A M m 00) 0 r- 0 M c cl) (5) CONCRETE/MASONRY MIX NO -TR TH (1cl DESIGN S E TH (f'c) c 0) . M 0 I SUPPLIER_ P C TOTAL CU. YD. PLAC SLUMP (INCHES) ,A ST SPECIMENS CAST AIR CONTENT (%) SEE CYLINDER REPORT NO. z ��—YES INSPECTED WERE IN CONFORMANCEWITH BLDG. DEPT. APPROVED PLANS _NO —ITEMS z REMARKS: A117 0 m s 7,4.FIJV I.- IlIV76 h� -21'v Z. 6 1,J 7,�4 D 7 2006 0 t N sERVIC C , WN N TR. S J TEST RESULTS APPLY ONLY TO THE ITEMS HEREIN TESTED. THIS REPORT 9HALL NOT INSPECTOR(S), NA ME(S) PRINTED BE REPRODUCED EXCEPT IN. FULL, WITH- OUT THE WRITTEN APPROVAL OF.CASCADE INSPECTOR SIGNATURE TESTING LABORATORY, INC. REVISED 7105 SIGNED BY COPIES TO' L (425) 023.9000 (425) 2S9-0817 FIELD REPORT TO: /4 -,r=v ATTN: THE FOLLOWING WAS NOTED; DATE =�XENQ�U=M�� �CERT. zz Ame-IM-106 � �NO. Z�- PROJECT LOCATION PERMIT NO. OWNER EBLDG. WEATHER 7__EEd TEMP. AT AM AT PM ENGINEER ARCHITECT L"-65 CONTRACTOR hf1&7eav_ lwlAga:5 lAr, V7 M 0. 8c: Mm m 10 71 7OF I " c z v :3= Btr, ZAV7 r LiTrAob - _n m M 0 0 r 0 M. M 0. z z 3: m RECEIY_E�D TEST RESULTS APPLY ONLY -TO THE ITEMS HEREIN TESTED. THIS REPORT SHALL NOT INSPECTOR(S), NAME(S) PRINTED A 7AV6oW" khe BE REPRODUCED EXCEPT IN FULL WITH- OUT THE WRITTEN APPROVAL OF CASCADE DEVELOPMENIf SEFiVicl:s CTR. TESTING LABORATORY. INC. INSPECTOR SIGNATUR CITY OF FONIONE '000p� s LREVISED 1102 :N Cop STO.MM_ IE Id I CASCADE TESTING LABORATORY, JNC. TESTING & INSPECTION PREVIOUS 1 2919 N.S. 126TH PLACE REPORT No. No. "IRKLAND, WASHINGTON 98034 (425) 823-9800 EVERETT (425) 259-0817 DATE �E F/aD REFIC)RT PROJECT LOCATION TO: BLDG. PERMIT NO., OWNER (& tj u WEATHER S TEMP. AT AM AT PM ENGINEER ARCHITECT ATTN: CONTRACTOR (2) INSPECTION PERFORMED (3) ITEMS INSPECTED FOUNDATIONS RESTEEL/CONCRETE RESTEEL ONLY FOOTINGS SLAB RESTEEL/MASONRY STR.STfWELDING AUGER CAST PILES COLUMNS OTHER STR.STIBOLTING DRILLED PIERS WALLS BEAMS (4) LOCATION (AREAS) Z"1sz_1x"Z__"1 T lye), (5) CONCRETE/MASONRY MIX NO. DESIGN STRENGTH (f'c),-. SUPPLIER TOTAL CU. YD. PLACED SLUMP (INCHES) SPECIMENS CAST AIR CONTENT (%) SEE CYLINDER REPORT NO. —YES —NO ITEMS INSPECTED WERE IN CONFORMANCEWITH BLDG. DEPT. APPROVED PLANS Gel - REMARKS: Ale j/l 7b L /m Zv RECEIVED MAR 2 2006 DEVELOPMENT SERVICES CTR. CITY OF EDMONDS TEST RESULTS APPLY ONLY TO THE ITEMS HEREIN TESTED. THIS REPORT SHALL NOT INSPECTOR(S), NAME(S) PRINTE BE REPRODUCED EXCEPT IN FULL, WITH- OUT THE WRITTEN APPROVAL OF CASCADE Z TESTING LABORATORY, INC. INSPECTOR SIGNATURE ------------ elflKirzil QV 0 m -4 0 m Height Calculation Worksheet. Date CA, Permit. Number 77o-7 Address �j . Inspector NNn� Zi A e Grade v. rage ght (25'+Av Max Rei e.) Actual Height (A+B+C) -2) -4 3: M C 0: 0: C M Z� 0 M M 0 —(C Q 0 Z r X, C (40 z v Elevation of transit abo e Datum (B). Datum MID n'. Elevation (A) 3U 8) -06 1/temp/b u i Idi nW fonns/hei gilt workilleet FINAL PROJECT APPROVAL FORM TO: DATE: MEMO TO: PERMIT COORDINATOR, BUILDING DIVISION FROM: FIRE DEPARTMENT DATE PLRASr SIGN ENGINEERING DlVtSIONIDATE SIGN z 0 PLANNING DIVISION DATE 0 M PLEASESIGN PROJECT CO C M SITE ADDRESS M 0 ADB#_DATE INSPECTED �e_ 0 C: -1 K PERMIT 3: M MZ DESCRIPTION OF WORK TO BE INSPECTED C z A field, inspection was conducted to determine comp liance with -approved, plans. Final approval denotes that, there are n o objections from the above signed Department to the release. of 0 -n PERFORMANCE BONDS and the granting of M M 0 ui FINAL PROJECT APPROVAL 0 0 M C rj) F. Cn ____,LGRANT MO Z 7-1 M GRANT PROJECT APPROVAL WITH CONDITIONS NOTED z IONS iven to owner/contractor by. inspector 0 Copy of CONDIT 9 Cn z 0 .4 'FAILED FINAL INSPECTION OUTSTANDING ISSUES, 0 M Copy of CORRECTIONNOTICE given. to owner/contractor by inpector 2. 3. RE INSPECTE D OUTSTANDING ISSUES - GRANT FINAL PROJECT APPROVAL Date Signature 1:tcmp4b1dg:fomis:oca prvl 3/25/04 p FINAL PROJECT APPRO'VAL FORM TO: DATE: MEMO TO: PERMIT COORDINATOR, BUILDING DIVISION FROM: FIRE DEPARTMENT DATE PLEASE SIGN ENGINEERING DIVISION DATE 912 z .0 Pix.&SE SOM --i 0 PLANNING DIVISION DATE M PIXASE SIGN =n PROJECT 2 F- (P,- C/) x 0 4 C M M0 0 SITE ADDRESS- C7,2 0 -92 0 0 C PERMIT 1t,2VV)__-3 — (Z) Zo Z ADBft DATE'fNSPECTED a: M �M Z DESCRIPTION OF WORK TO BE INSPECTED 6�2 /Ir/ t— (76) C: z Cn A field inspection, was conducted to determine compliance with -approved plans. Final. apprioval 0 -n denotes that there are no objections from the above signed Department to the release of -n PERFORMANCE BONDS and the granting of M M 0 r 0 M C (n GRANT FINAL PROJECT APPROVAL MO z X z GRANT PROJECTAPPROVAL WITH CONDITIONS NOTED 0 Copy of CONDITIONS given to owner/contractor by inspector (n z 0 M FAILED FINAL INSPECTION -.OUTSTANDING ISSUES 0 Copy of CORRECTION NOTICE given to owner/contractor by inpector 2. .3. RE -INSPECTED OUTSTANDING ISSUES - GRANT FINAL PROJECT APPROVAL Date Signature I:Ietiip.:bl(lg:fornis:ocal)i-vI 3/25/04 RECORD OF INSPECTIONS INSPECTOR DATE APPROVED SETBACKS ..................... FOUNDATION: Footing....................... Wall.......................... Pier/Porch ................. z 0 Retaining Wall ........... 0 Slab Insulation .......... 46� jpk.!�� PLUMBING: I c� Underground ............. 0) --j M Rough -In ................... C M 0 V-14 Commercial Final ...... 0 0 C HEATING: 3: M M z 3 Gas Te 10-4 st ........ .......... C z > Gas Piping ................. EPT9Y -4 Equipm ent ................... 0) 0 -n -n 4 s commercial Final ....... -1 3:9 6 M ITI EXTERIOR SHEATHING 055 NAILING.......................... 0 0 ITI FRAMING ......................... C C0 (j) FIRST FLOOR FRAMING... Q0 Z r INSUL ATI.ON ... I ................ Floor Insulation ...... > Ar Wall Insulation ............ z Ceiling* Insulation* ....... SHEETROCK NAILING ... z 0 SPECIAL INSPECTION ... 0 ITI MISCELLANEOUS .......... 1�7a FINAL APPROVAL FOR v- OCCUPANCY .................. r rLtytt AMootm$ Ree*t A &V t DW ed walwMetwSize— AMOUDtpwd- /zk�—Recdpt#�a 0 7 pateft ROW# AMOUntPWd$ Reedpt Datelssued ed