20060620131729.pdfE D City of Edmonds 0 PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: June 20, 2006 TO: Ronald D Johnson 1960123" Ave NW Shoreline, WA 98177 FROM, Jenny Readwin, Plans Exam4q---" RE: Plan Check # 2006-0661 Project: Antonowitsch SFR Project Address: 23214 92nd Ave W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the above items to a Permit Coordinator. 1) Specify datum point and elevation on the site plan. 2) Complete the enclosed plumbing fixture count worksheet. 3) Show how island sink will be vented through the roof or with a loop vent as permitted by UPC 909.0.Air admittance valves are not permitted unless first approved by the Building Official under and alternate method per UPC 301.2. 4) Show size and location of whole house fan. 5) Show all fixtures (sink, dishwasher, etc.) in the basement wet bar. 6) Specify on the elevation views the grade slope away from the building. If minimum 6" within 10' is not possible or habitable or useable space is below grade, foundation drainage is required - Provide footing drain detail on foundation sections complying with R405.1 and show required drain locations on the foundation plan. 7). Per our Single Family Residence Handout B73 a complete soils report is required when the lot slope exceeds 15%. Per my calculations this lot is 17%. Provide complete soils report (see attached handout for minimum report requirements). Required special inspections will be determined once a complete report is submitted. 8) See attached structural comments from city consultant. Respond to each item in writing. Eagle Eye Consulting Engineers, P.S. PO Box 523 01alla, WA 98359 hoytjeter@centurytel.net 2538574151 Fax 253 857 5759 To: Marie Harrison City of Edmonds WA Re: Antonowitsch Residence 2321492 nd Ave W Edmonds WA Plan Review # 06-232 Main Floor 1627 Lower floor 1438 Total 3065 Garage 522 Total 3587 Patio 216- Deck 200 Porch 56' Grand total 4059 Rze-J7A Date: June 5, 2006 EECE # EDM 06-25 RECEIVED J U N — b 2.006 BUILDING DEPT. The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the architectural Structural Only requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 3 EECE#: EDM 06-25 ANTONOWITSCH RESIDENCE STRUCTURAL COMMENTS Sheet 8 of 10 Main floor framing 1. Due to the different stifffiess of the concrete shear wall and wood shear wall the code required smallest R factors to be used. The analysis used an R factor of 6.5 which is not correct for the stiffer concrete shear element. The R factor for concrete shear walls that are used for bearing shall be 4.5. The diaphragin also must be analysis with the smaller R factor. Resubmit analysis and drawing to account for this. IBC 167.6.2.2 and IIBC 1617.6.2.3 2. Please provide analysis for the lateral transfer for the deck support. Without having X bracing, diagonal bracing or knee braces there is no lateral transferred specified. Please provide analysis to justify deck framing to transfer these loads and detail accordingly. IIBC 1604.4 3. Please specify the required post to beam connections. All that is stated is 4X6 post each end. Due to seismic event in the northwest it is important to specify the required connection on the drawings. IIBC 1603.1 4. Please specify the required hanger noted on the drawings. The drawing state joist hanger to rim. It was unclear what the required size would be in order to check capacity. 1BC 106.1.1 Sheet 9 of 10 Roof Framing 5. AOR please provide detail on the drawing for the drag trusses to transfer the lateral load into the interior shear wall. I was unable to find where this was called out. EBC 1603,1 6. AOR please provide detail for the connection of the 4XIO beams to the post at the wall. Nothing is called out at this time. (Porch) EBC 2304.9.7 7. AOR please specify the required post connection of the 6X6 to the glu-lani beams on the drawings. One place all that is stated is 6X6 each end. A connection is required to be specified. Please either point out where this is called out or add to the drawings. 113C 2304.9.7 8. AOR please specify the required connection of the 5-1/8X9 glu-lam, header to the jamb studs. A positive connection is required to be specified. ( Great Room) EBC 2304.9.7 9. AOR provide calculations for the (2) 2x6 supporting the hip girder truss. ( Garage area) EBC 1603.1 Page 3 of 3 EECE#: EDM 06-25 ANTONOWTTSCH RESIDENCE 10. AOR please specify the required connection of the 6X8 at the intersection of the girder truss. (Master bedroom) IBC 2304.9.6 Sheet 10 of 10 Sections 11. Detail 1, 2, 5, and 8. Straight bar embedment will not develop the reinforcing steel, please note 90 degree hook is required at the vertical bars into the footing. Please add this to details or justify by analysis not required. R403.1.3 12. Provide calculation for the Joist U hanger to be used nailed through the ply wood into the continuous rim. The nails are only 1-1/2 long and the published data is based off the hanger nails being fully nailed into a solid piece of lumber. Unless specifically called out to use standard I Od standard size the 1 ODX 1 - 1/2 are used. Having 7/16" plywood this only allows I" embedment. (Note also Simpson does not publish U28 hangers anymore in there catalog and per the Simpson engineering department they have discontinue these hangers for awhile and recommend using another hanger. Simpson phone number 1-800 999-5099) Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (253) 857-4151 between 8:00 a.m. and 5:00 p.m. By: Hoyt Jeter, P.E. President I PLUMBING FIXTURE COUNT Number Fixture Type Water Closet (Toilet) Sink (Including laundry sink, bar sink, etc.) Lavatory (Bathroom sink) Tub/Shower Dishwasher Clothes Washer Hose Bib (Exteror water faucet) Hot Water Tank Expansion Tank (for water heater) Floor Drain Backflow Protection Device Pressure Reduction Valve Grease Trap Water Service Line Drinking Fountain IBidet / Urinal GAS OUTLETS AC Unit Furnace BTU's Water Heater Boiler Dryer Stove/Range/Oven Gas Fireplace/Logs/Insert Outdoor Barbeque Total Gas Piping Outlets lAppliance Location