Loading...
20060621094611.pdfCity of Edmonds Plan Review Corrections Plan Check#: 06-255 Date: June 21, 2006 Project Name/Address: Greenberg @ 155 3rd Avenue S Contact Person/Address/Fax: Doug Buehler @ 425-335-4645 Permit Coordinator: Marie Harrison 425.771.0220 x 1389 Department: Building The following City of Edmonds departments have reviewed your application: [ ] Building Department [ ] Planning Department [ ] Recycling [ ] Pretreatment [ ] Engineering Department [ ] Water Quality XFire Department Attached are comments and corrections from the appropriate departments. Please respond to all comments and corrections and resubmit your corrections to all departments at one time. Please bubble your corrections and submit three sets of corrected sheets. No partial resubmittals will be accepted. Thank you, Senior Permit Coordinator 425.771.0220 x 1389 harrlson(5_ci.edmonds.wa.us ��'< i If (4/ f 4affo 4", el �p DATE FAXED 40IL9,1 of (Attach fax transmittal Page LfT'emp/DST/Forms/plan-review9/01 Eagle Eye Consulting Engineers, P.S. PO BOX 523 Olalla WA 98359 C:206 356-7790 P:253 857-4151 F: 253 867-5759 To: American Sprinkler Corp. 2311 153rd Avenue SE Snohomish, WA 98290 Attn: S. Adamson Re: Greenberg Mixed Use Building P Avenue South & Dayton St. Edmonds, WA Plan Review Number # 06-255 EECE EDM06-28 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes (Fire Code only). The following comments, deficiencies/coffections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -cheek time. SCOPE OF REVIEW The scope of this review isfor fire suppression requirements of thisproject. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Greenberg Mixed Use Building Page 2 of 2 3rd Ave South & Dayton St. Plan Review Number #06-255 EECE # ED06-28 FIRE ALARM COMNENTS General 1. Provide an inspectors test valve for the wet system in a remote location. Show on the plans and resubmit. NFPA 13, 8.16.4.2 2. Calculations for the Wet System: Include the friction loss for the flow switch in the calculations. This is required for flow switches in pipes of 2 inches or less. Resubmit. NFPA 13,14.4.4.5 Sheet 2 Basement 3. Sheet 2: Please provide a sprinkler head in the riser room. Show on the plans and resubmit. NFPA 13, 8. 1.1 Sheet 4 2 d Floor 4. Please provide a sprinkler head at the top of the elevator shaft. Show on the plans and resubmit. -NFPA 13, 8.14.5.4 5. Please provide sprinkler heads for the covered balcony/deck areas. Show on the plans and resubmit. NFPA 13, 8.14. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (253) 857- 4151 between 8:00 a.m. and 5:00 p.m. By:_z Hoyt Jeter PE President