Loading...
2006-0650_VarelaSFR.doc CE ITY OF DMONDS th 121 5 Avenue North • Edmonds, WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www.ci.edmonds.wa.us DSD: P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING Plan Review Comments – Planning Division Plan Check #: BLD-2006-0650 Project Name: Varela New SFR th Project Address:9313 190 Street SW – RS-10 Zone June 12, 2006 Arthur & Annette Varela th 19619 88 Avenue West Edmonds WA 98026 Phone: 425.218.3209 / Fax: none given Dear Mr. & Mrs. Varela, I have reviewed the above building permit application for the Planning Division and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: Lot Area: 1. Please update the lot area on the site plan (10,394) to reflect the lot area on the recorded plat map (10,391). SEPA: 2. Please be aware that if 500 cubic yards of grading (of either cut or fill) is proposed, then an Environmental Checklist, an APO list, and a SEPA review fee will be required. Height Calculations: 3. Point A of the height rectangle is located off site. Please confirm: was this elevation of 268 derived by the following method outlined in ECDC 21.40.030.B? If not, please revise and update height calculations (and elevations) accordingly. ECDC 21.40.030.B states: “If a corner falls off the site, its elevation shall be the average elevation of the two points projected downward where the two sides of the rectangle cross the property line.” Rockery: 4. Please be aware that the maximum height of the rockery in the setback area cannot exceed three feet as measured from the top of the wall to the original grade. Please confirm: what is the original grade in this area? Chimney: 5.Please note the following exception to the height limit, pursuant to ECDC 23.40.030.C.4: “Chimneys, not to exceed nine square feet in horizontal section or more than three feet in height, for that portion above the height limit.” What is the area of the horizontal section that exceeds the height limit (please be aware that it cannot exceed nine square feet)? Plat Map: 6.When you receive your copy of the recorded plat map back in the mail, please submit two copies to the Planning Division. We know that the short plat has been recorded Page 1 of 2 (AFN 200605085002), however the copy submitted to the City does not yet have the Auditor’s signature on it (apparently they will mail it to you after they sign and process it?). Thank you for your cooperation. Please redline plans or submit three sets of revised plans/documents (affected sheets only) with a written response to each of the above items. Please make all submittals to the Development Services Permit Coordinator Monday through Friday, 9am to noon or 1pm to 4pm. If you have any questions, please do not hesitate to contact me at (425) 771-0220, extension 1778. I look forward to working with you on this project. Sincerely, CITY OF EDMONDS Gina Coccia, Planner Page 2 of 2