20060706093221.pdf0 City of Edmonds 0 PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: April 4, 2006 TO: Brian Hunt 22414 96"' Ave W Edmonds, WA 98020 FROM: Jenny Readwin, Plans Exami4w RE_- Plan Check # 06-102 Project SFR addition and detached garage Project Address: 22414 96b Ave W. During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Specify distance between the garage and the addition on the site plan. If less than 6', minimum Y2" sheetrock in the garage along this area is required as well as a 20 minute or 13/8" solid core door. Note on plans. 2) Label covered porches on the site plan (front and rear). 3) Elevation views and impervious surface calculations on the site plan specify the front porch to be covered but this is not shown on the structural plans. Provide complete framing plans for front covered porch. 4) Show location of carport to be demolished on the site plan or provide separate site plan for demolition permit. 5) Written bid is for kitchen remodel only. Revise or provide supplemental written bid for other interior -work shown on the plans (i.e. front entry, angle wall, master bedroom closet, etc.). 6) Complete the enclosed plumbing fixture count worksheet for all new, extended or relocated fixtures. 7) Provide crawlspace ventilation calculations and show size and location of crawlspace vents on foundation plan. No vents are shown between the new and existing foundation. Are there vents along this wall? If so, provide calculation for additional vents in new addition to account for vents being blocked along this. wall. 8). Note 6 on sheet A-2 states that the furnace will be in the attic. Provide calculations for existing roof framing to show that it is capable of being supported by the ex ' isting framing. Also, show how all requirements of IRC MI 305.1.3 will be met (height, clearance to combustibles per manufactures specs, access opening, work space, platform, light, passageway, etc.) as well as combustion air per Chl.7 IRC. 9) It.appears that there will be a site built shower in bathroom #2. Provide shower pan construction detail for shower construction. 10) Special inspections are required for the following. Complete the enclosed special inspection agreement -signed by the owner, the general contractor and the special inspector and submit to the City for approval prior to issuance. KwIck bolts Epoxy anchor bolts and holdowns Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with aw.ritten response to each -of the above items to a Permit Coordinator. CITY OF EDMONDS SPECIAL INSPECTION AND TESTING AGREEMENT The project at j�aql�L_q(A av-e 0 issued under building permit number & - requires special inspection and/or testing per IBC Chapter 17. The complete list of special inspections is attached to this document. BEFORE A PERMIT CAN BE ISSUED: The owner and contractor and special inspector shall complete this agreement and the attached structural test(s) and inspections schedule including the required acknowledgements. APPROVAL OF SPECIAL INSPECTORS: Each special inspector shall be approved by the Building Official prior to performing any duties or inspections. Each special inspector shall submit Statement of Qualifications to the Building Official for review. Special inspectors shall display identification when performing special inspections on site. Special inspection and testing shall meet the minimum requirements of IBC Chapter 17 and the following: A- Duties and Responsibilities of the Sperial-Inspecto .1. Observe Work The special inspector shall observe the site work for conformance with the approved (stamped) plans and specifications and applicable workmanship provisions of the IBC. Architect or Engineer reviewed shop drawings may be used only as an aid to inspection. Special Inspections are to be performed on a continuous basis —meaning that the special inspector is on site at all times observing the work requiring special inspection. Periodic inspections, if any, must have prior approval by the City based on a separate written plan reviewed and approved by the Building Official and the engineer or architect of record. 2. Report Non -conforming Items The special inspector shall bring non -conforming items to the immediate attention of the contractor and note all such items in the daily field report. Any item not resolved in a timely manner shall be immediate cause of the special inspector to notify the Building Official of the plan deviation, error, change or omission. It shall also be the duty of the special inspector to promptly notify the engineer or architect. 3. Complete Daily Reports Each special inspector shall complete and sign both the special inspection record and the daily report form for each day's inspection. These records shall remain at the jobsite with the contractor for review by the City Building Inspector. 4. Furnish Weekly Reports The special inspector or inspection agency shall furnish the City with weekly reports of tests and inspections. The project engineer or architect, and others as designated shall also be copied on reports. Weekly reports must include the following: Description of daily inspections and tests made with applicable locations List of all non -conforming items Report on status of non -conforming items (resolved or unresolved) Itemized changes authorized by the Architect, Engineer and City if not included in non- conformance items. 5. Furnish Final Construction Report The special inspector or inspection agency shall submit a final signed report to the City stating that all items requiring special inspection and testing were fulfilled and reported. And, to the best of L.:\TEMP\BUILDING\SpeciallnspectionAgreementIBC.doc 7/04 hisfher knowledge the project is in conformance with the approved plans and specifications, approved change orders and the applicable workmanship provisions of the IBC. Items not in conformance or unresolved items or any discrepancies in inspection coverage, (i.e., missed inspections, periodic inspection when continuous inspections were required, etc.) shall be specifically itemized in this report. B. Contractor Responsibilities 1. Notify the Special Inspector It is the duty of the contractor to notify the special inspector when work is ready for special inspection. Note, the items listed on the attached schedule and as noted on the approved plans and specifications are required to have special inspections. Adequate notice shall be provided by the contractor so that the special inspector has time to become familiar with the project. 2. Provide Access to Approved Plans The contractor is responsible for providing the special inspector access to approved plans at.the jobsite. 3. Retain Special Inspection Records The contractor is responsible to retain at the jobsite all special inspection records submitted by the special inspector. These records are to be provided to the City building inspector upon request C. City of Edmonds Buildine Department Responsibilities 1. Approve special inspectors or inspection agencies The building department shall approve all special inspectors and special inspection requirements. 2. Monitor special inspection and approve weekly reports Work requiring special inspection and the performance of special inspectors shall be monitored by the City Building Inspector. 11is/Her approval must be obtained prior to placement of concrete or other similar activities in addition to that of the special inspector. 3. Issue Certificate of Occupancy � The Building Official may issue a Certificate of Occupancy after an weekly special inspection reports including the final report have been submitted and accepted. D. Owner Responsibilities The project owner or the engineer or architect of record acting as the owner's agent shall fund special inspection services. E. Engineer or Architect of Record Responsibilities The engineer or architect of record shall include special inspection requirements on the plans and specifications. ACKNOWLEDGEMENTS I have read and agree to comply with the terms and conditions ofthis agreement. Owner Special Inspector General Contractor City BuUding Official Date Date Date Date L:\TEMP\BLfILDING\SpecialInspectionAgreementiBC-doc 7/04 INSPECTION AND TESTING SCHEDULE PROJE�TNAME 414 �-11 .,3 to, n_dA�f�� PROX:CT ADDRM TE��� A%se4cr " spaiAL v4spEctoit REINFORCED CONCRETE, GUNITE, GROUT AND MORTAR: STRUCTURAL STEELIWELDING: Concr"e Gunke Grwa Morlw — Sam le and Test frw spec -if . P ic nembers below) - Shop Matesial Identification Reitiforcing,Tests — Welding Inspection 0 SbV 0 ReW Nfix Designs — uItrawnic Inspection DShOp 0 Field 1 Reinforcing Placement — ffigli-strength Bolting Batch Plant hispccrron Inspection Shop 0 Field bispect Placing 0 A325 Cast sampks 0 A490 0 N 0 x 0 F P"-up Samples Mcul Deck Welding Inspection cornprcssiort Tests Reinforcing Steel welding Inspeti. PRECASTIPREMESSED CONCRETE: Metal Stud Welding Inspeaion Concrete Insen Welding Inspection Filts Post Tens Pre-Ttas Clddmg ft—g—Tests FlREPROOFING: Rcinfmcing Tests — Placement Inspection Tendon Tests — Density Tests Mix Destaw — Tlickoess Tests Reinfofring Placement — Inspect batching Insen PlacerricnE Concrete Ratching INSULATING CONCRETE: concrete I'Licement — Sample and Test butallation I risWi n — Placement Inspection Cast Samples — Unit Weights 'Pick-up Samples jCompressionTcsts FILL MATERIAL: MASONRY — Acceptance Tests — Placenterd Inspection — Special Inspection STcssrs Used — Field Density — I'mliminaryAcccptance Tests (Masonry Units. Will Pfisuls) — Stlb-q—t Tests fMortar. Grout, Field Wan Prism) STRUCTURAL WOOD: — Placemcm Inspection of Units — Shear Wall Nailing Inspection — Inspection of Glu-larn Fib- - Inspection of Truss Joist Fab. ADDITIONAL INSTRUCTIONS OR OTHER TESTS — Sample and Test Components AND INSPECTIONS: Form compk-ted by- Title: Tcicphoxw No-: PLUMBING FIXTURE COUNT Number Fixture Type Water Closet (Toilet) Sink (including laundry sink, bar sink, etc.) Lavatory (Bathroom sink) Tub/Shower Dishwasher Clothes Washer Hose Bib (Exteror water faucet) Hot Water Tank Expansion Tank (for wate.r heater) Floor Drain Backflow Protection Device Pressure Reduction Valve Grease Trap Water Service Line Drinking Fountain Bidet / Urinal GAS OUTLETS AC Unit Furnace BTU's Water Heater ,g r Boil . Dryer Stove/Range/Oven Gas Fireplace/Logs/insert Out door Barbeque Total Gas Piping Outlets lAppliance Location