Loading...
20060712132510.pdf-COMM, JOURNAL- DATE MAY-10-2006 ***** TIME 12:14 *** P.01 MODE = MEMORY TRANSMISSION FILE NO.= 016 STN NO. COKJ ABER NO. STATION NAME/TEL.ND 001 9425??81910 01F CD4r 0 %1P DATE: May 10, 2006 START=MAY-10 12:12 PAGES DURATION 007/007 00:02'14" Citj of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 TO: Jan Newman Fax (425)778-1910 FROK Jenny Readwin, Plans Exami* RE: Plan Check 4 06-145 Project: Conternpra SFR Project Address: 8044 Cyrus Place END=MRY-10 12:14 During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/docurnents (affected sheets only) with a written response to each of the above items to a Permit Coordinator, Provide top and bottom wall elevations for all proposed rockeries. Rockeries located in a critical area arc required to be designed and stamped by a Washington State Licensed Professional Engineer. Provide stamped and signed calculations and construction details for proposed rockeries. 2) Label datum point on the site plan. 3) Per Geotech report submitted minimum footing widths shall be 18" and 24". Revise foundation plan to reflect foundation recommendation of Geotechnical report. 4) Provide site specific foundation plan showing all steps to account for variation in grade. Alter foundation details accordingly, 5) Provide letter from Geotechnical Engineer of Record stating that they have reviewed the plans and that they are consistent with the report recommendations. 6) Special inspections are required for the following. Complete the enclosed special inspection agreement signed by the owner, the general contractor and the special inspector and submit to the City -for approval prior to issuance. • Layout of foundation alignment with regard to top -of -slope • Soil cuts • Foundation sub -grade verification • Any retaining wall, or rockery placement • Any fill placement • Subsurface drainage installation (including footing drains) • Temporary and final erosion control measures • Slope stabilization/grading activities 7) See attached structural comments from city consultant. Respond to each itern in writing. 0 ED DATE: May 10, 2006 Cily of . Edmonds PLAN REVIEW, COMMENTS BUILDING DIVISION (425) 171-0220 TO: Jan Newman Fax (425)778-1910 FROM: Jenny Readwin, Plans Exami* RE: Plan Check # 06-145 Project: Contempra SFR Project Address: 8044 Cyrus Place During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the above items to a Permit Coordinator. 1) Provide top and bottom wall elevations for all proposed rockeries. Rockeries located in a critical area are required to be designed and stamped by a Washington State Licensed Professional Engineer. Provide stamped and signed calculations and construction details for proposed rockeries. 2) Label datum point on the site plan. 3) Per Geotech report submitted minimum footing widths shall be 18" and 24". Revise foundation plan to reflect foundation recommendation of Geotechnical report. 4) Provide site specific foundation plan showing all steps to account for variation in grade. Alter foundation details accordingly. 5) Provide letter from Geotechnical Engineer of Record stating that they have reviewed the plans and that they are consistent with the report recommendations. 6) Special inspections are required for the following. Complete the enclosed special inspection agreement signed by the owner, the general contractor and the special inspector and submit to the City for approval prior to issuance. • Layout of foundation alignment with regard to top -of -slope • Soil cuts • Foundation sub -grade verification • Any retaining wall, or rockery placement • Any fill placement • Subsurface drainage installation (including footing drains) • Temporary and final erosion control measures • Slope stabilization/grading activities 7) See attached structural comments from city consultant. Respond to each item in writing. Eagle Eye Consulting Engineers, P.S. PO Box 523 01alla, WA 98359 hoytjeter@centurytel.net 2538574151 Fax 253 857 5759 To: JoAnne Zulauf City of Edmonds Edmonds, WA 98020 Re: Contempra Homes 8044 Cyrus PI Edmonds, WA 98020 Plan Review # 06-145 Structur, I Area SS' First floor 1556 Second floor 1923 Total 3479 Garage 634 Total 4113 Porches 206 Grand total 4319 21 Date: April 26, 2006 EECE # EDM 06-19 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review isfor the structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or wilt meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 3 EECE#: OrojectID)) <<Pr0JectDescn'ption>) STRUCTURAL COMMENTS Sheet A3 FOLTNDATION PLAN: 1. Architect of Record (AOR), please specify the required hanger to be used for the doublejoist. 2. AOR, please specify the size of the footing to be used at the perimeter columns. 3. AOR, provide an analysis for the footing at the comer of the nook and kitchen considering an eccentric load on the footing. A check of analysis shows as drawn (scaled) that the beaning pressure will be exceeded. Provide an analysis to justify. EBC 1801.2 4. Please specify the required support at the wood columns. This is required to resist lateral translation (this shall include the multiple studs that are used as posts). EBC 2304.9.7 Sheet A4 MAIN FLOOR PLAN: 5. Please specify the required connection of the glu-lam beam to the post supporting them. I was unable to find where this was called out on the drawings. E3C 2304.9.7 6. The design of the gl-u-lam beam assumes the top compression part of the glu-lam will be continuously supported. This is not the case as drawn. The joists are spaced at 16" O/C continuous over the beam and no attachment is shown connecting the j oist to the gl-u-lam beam. Please specify the attachment of the J oist to the glu-lam beam on the drawings and submit an analysis for the Lu equal to 16 inches and not zero. The glu lam beam must be checked using either the volume factor (Cv) or the stability factor Q. Please modify drawings accordingly. NDS 5.1 and 5.3.6 7. Please specify the required connection of the joist to the beams. Sheet G1 has not dealt with this. IIBC 2jO4.9.6 Sheet A5UPPER FLOOR PLAN: 8. The upper floor shows guard rails are required. Please provide a detail for the attachment of the guard rails on the drawings. This is required to resist a force of 200 pounds applied in any direction. EBC 1607.7.1 Page 3 of 3 EECE#: <<ProjectH)>) <&roj ectDescnptiort)) Sheet G-1 TYPICAL WALL SECTIONS: 9. Typical Wall Section: Please note on the detail that the reinforcement steel shall have a 90 degree hook. The bars can not develop with straight bar embedment. 11BC 1907 and R403.1.3 10. Typical Wall Section: Provide an analysis that a 1/2" diameter anchor will prevent lateral resistance at the base. Colurmi ends are required to resist lateral forces. EBC 2304.9.7 Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (253) 857-4151 between 8:00 a.m. and 5:00 p.m. By: Hoyt Jeter, P.E. President I CITY OF EDMONDS SPECIAL INSPECTION AND TESTING AGREEMENT The project at r-A,/'V'F U JZ> Q- t-, . issued under building permit number requires special inspection and/or testing per IBC Chapter 17. The complete Est of special inspections is attached to this document. BEFORE A PERNUT CAN BE ISSUED: The owner and contractor and special inspector shall complete this agreement and the attached structural test(s) and inspections schedule including the required acknowledgenients. APPROVAL OF SPECIAL INSPECTORS: Each special inspector shall be approved by the Building Official prior to performing any duties or inspections. Each special insp ector shall submit Statement of Qualifications to the Building Official for review. Special inspectors shall display identification When performing special inspections on site. Special inspection and testing shall meet the minimum requirements of IBC Chapter 17 and the following: A. Duties and Responsibilities of the Special Inspector 1. Observe Work The special inspector shall observe the site work for conformance with the approved (stamped) plans and specifications and applicable workmanship provisions of the IBC. Architect or Engineer reviewed shop drawings may be used only as an aid to inspection. Special Inspections are to be performed on a continuous basis —meaning that the special inspector is on site at all times observing the work requiring special inspection. Periodic inspections, if any, must have prior approval by the. City based on a separate written plan reviewed and approved by the Building Official and the engineer or architect of record. 2. Report Non -conforming Items The special inspector shall bring non -conforming items to the immediate attention of the contractor and note all such items in the daily field report. Any item not resolved in a timely manner shall be immediate cause of the special inspector to notify the Building Official of the plan deviation, error, change or omission. It shall also be the duty of the special inspector to promptly notify the engineer or architect. 3. Complete Daily Reports Each special inspector shall complete and sign both the special inspection record and the daily report form for each day's inspection. These records shall remain at the jobsite with the contractor for review by the City Building Inspector. 4. Furnish Weekly Reports The special inspector or inspection agency shall furnish the City with weekly reports of tests and inspections. The project engineer or architect, and others as designated shall also be copied on reports. Weekly reports must include the following: • Description of daily inspections and tests made with applicable locations • List of all non -conforming items Report on status of non -conforming items (resolved or unresolved) Itemized changes authorized by the Architect, Engineer and City if not included in non- conformance items. 5. Furnish Final Construction Report The special inspector or inspection agency shall submit a final signed report to the City stating that all items requiring special inspection and testing were fulfilled and reported. And, to the best of .L:\TEMP\BUMDING\SpeciallnspectionAgreementIBC.doe 7/04 his/her knowledge the project is in conformance with the approved plans and specifications, approved change orders and the applicable workmanship provisions of the IBC. Items not in conformance or unresolved items or any discrepancies in inspection coverage, (i.e., missed inspections, periodic inspection when continuous inspections were required, etc.) shall be specifically itemized in this report. B. Contractor Responsibilities Notify the Special Inspector It is the duty of the contractor to notify the special inspector when work is ready for special inspection. Note, the items listed on the attached schedule and as noted on the approved plans and specifications are required to have special inspections. Adequate notice shall be provided by the contractor so that the special inspector has time to become familiar with the project. 2. Provide Access to Approved Plans The contractor is responsible for providing the special inspector access to approved plans at-4he jobsite. 3. Retain Special Inspection Records The contractor is responsible to retain at the jobsite all special inspection records submitted by the special inspector. These records are to be provided to the City building inspector upon request. C. City of Edmonds Buildin2 Department Responsibilities 1. Approve special inspectors or inspection agencies The building department shall approve all special inspectors and special inspection requirements. 2. Monitor special inspection and approve weekly reports Work requiring special inspection and the performance of special inspectors shall be monitored by the City Building Inspector. His/Her approval must be obtained prior to placement of concrete or other similar activities in addition to that of the special inspector. 3. Issue Certificate of Occupancy The Building Official may issue a Certificate of Occupancy after an weekly special inspection reports including the final report have been submitted and accepted. D. Owner Responsibilities The project owner or the engineer or architect of record acting as the owner's agent shall fund special inspection services. E. Engineer or Architect of Record Responsibilities The engineer or architect of record shall include special inspection requirements on the plans and specifications. ACKNOWLEDGEMENTS I have read and agree to comply with the terms and conditions of this agreement. Owner Date Special Inspector Date Ge neral Contractor Date City Building Official Date L-.�TEMP\BUILDI,NG\SpeciallnspectionAgreement]BC.doe 7/04 SPECIAL INSPECTION AND TESTING SCHEDULE 12� ic BITUMM PEX4ry No, TEMINGaNSJT;Ct� AGENCY w SPUIpX INSPECTOR REINFORCED CONCRETE, GUNITE, GROUT AND MORTAR- STRUCTURAL STEELINELDING: Concrett Gunite Grout Mortar — Sample and Test (Iist specific membcrs beIvw) Aggreg� Tests — Sbop Material Mentification Reinforcing Tests — Welding Inspe-ti- ID sbop DFxid Mix Designs — Uh-- 111SP-n- D Shop f3 F=1d Reinforcing Placement — Higb-stmngth Bolting Bitch Plant lnspccum Inslx�cwn 0 Shop OFcld _h1sl)ectPIac*? El A325 El N 0 X D F Cast Samples D A490 Pick-up Sample — Metal Deck Welding Inspection 1 Compression Tests — Reinforcing Sicel WIdig Inspection PRECASTIPRESTRESSED CONCRETE: — Metal Stud Welding Inspection — Concrete Insert Welding Inspect" Piks P051-Tew Prv-Tens Claddwg Agg-g—Tests HREPROOFING: Reinforcing Tests — Placemcni Inspection TeMon Tests — Density Tests Mix DeSi2ns - Tbickriess Tests Reinforcing Placement — Inspect Batching Insert Placement Concrete Barcifing INSULATING CONCRETE: Concrete Placement Sample and Test Installation Inscpcoon — Placement Inspection Cast Samples — Unit Wcigbts I Pick-up Sampirs Comp sion Tests FILLMATERIAL: MASONRY — Acceptance Tes4s — Maccnxm Inspection — Special Inspection Stresses Used — Field Density — Preliminary Acceptance Tests fMasonry Units, Wall Prisms) — Subsequent Tests (Monar. Grout, Field Wall Prisms) STRUCTURAL WOOD: — Placemcal Inspection Of Units — Shear Wall Nailing Inspection — Inspection of Glu-Jam Fab� — Inspection of Truss Joist Rkb- ADDITIONAL INSTRUCTIONS OR OTHER TESTS — Sample and Test Components AND INSPECTIONS: Telephone No.: Date: