20060714100710.pdfD City of Edmonds PLAN REVIEWCOMMENTS BUILDING DIVISION St. 199 (425) 771-0220 DATE: July 14,2006 TO: Sofeea Kaufman kafeneo43@comcast.net FROM: Ann Bullis, Assistant Building Official RE: Plan Check # 20060784 Project: Storage addition (unheated) Project Address: 21108 Highway 99 In reviewing the plans for the above noted project, it was found that the following information, clarifications or changes are -needed. Please redline the plans currently on file with the City or submit 2 sets of revised plans/documents (affected sheets only) to Theresa Umbaugh, Permit Coordinator. 1 . On the site plan, clearly show and label the new storage enclosure. Relabel all other previously "new" work on the site plan to "existing" so there is no confusion as to what work is covered under this permit. 2. Cross out the details and portionsof the plan that do not apply to the storage enclosure so there is no confusion as to what work is covered under this permit. Also, the plans submitted do no match the approved plans for addition/remodel under permit #2005-0640 and appear to be plans that were submitted during the review process but were not approved.: For example, the loft storage and pull - down stair were -not approved. Revise the exiting configuration through the outdoor dining to match the . revision approved by the City for your addition/remodel on 7/13/06. 3. Enclosed storage area must be separated from the rest of the building with a I -hour fire ba ff*ier (since the storage area exceeds 100 square feet) per JBC 302.1.1. Provide a listed and tested 1-hour assembly (examples enclosed for wood wall) for the 1 -hour rated fire barrier wall. The existing portion of the exterior wall that is 8" CNW (masonry block) will meet the 1 -hour rating. The wall (both masonry and wood portions) must extend from the foundation to the underside of the roof sheathing. Doors in the fire barrier wall must be self closing, Y4hour fire rated (with label affixed to door by manufacture showing fire rating). Penetrations of the fire barrier, such as wiring, piping, etc. must be fire stopped with 1 -hour fire stopping assemblies. Revise plans accordingly. 4. The exterior wall construction as shown on the plans is considered non -conventional construction since the wall is not supported on a continuous foundation (like the rest of your building), which requires that the current design be engineered. Based on the date of the engineer's stamp currently on the plans, it is for the previous addition/remodel, not the current storage enclosure design. a. Have a State licensed professional engineer stamp and sign the current design with detail and supporting calculations to show that the post/beam construction will support the exterior wall including lateral. If you plan to support the wall on the existing concrete slab (rather than 8" above the slab), have the engineer also justify the slab thickness for the supporting wall as well as bottom plate connection to the slab, OR b. No. engineer is required if you provide a continuous foundation (footing and stem wall similar to detail I/A3 of the addition plans, or turn -down footing similar to detail 3/A3 of the addition plans) under the exterior wall with Y2" anchor bolts at.6' o.c. with minimum 7" embedment. GYPSUM WALLBOARD, WOOD STUDS, MINERAL FIBER INSULATION, FIBER -CEMENT BOARD, CERAMIC TILE One layer s/s" proprietary type X gypsum wallboard applied parallel on ONE SIDE of 2 x 4 wood studs 16" o.c. with 171s" smooth shank nails, 0.093" shank, 0.284" heads, 7" o.c. W, X Nil 31/2" mineral fiber insulation 3.0 pef, friction fit in stud space. OPPOSITE SIDE: One layer 7/16" proprietary fiber -cement board applied parallel to studs with 11/2' galvanized roofing nails 6" o.c. Ceramic file, 5/16" thick, joints grouted, installed Thickness: 5. with latex -modified portland cement mortar. Approx. Weight, 10 psf Rating based on the lesser of loading to 800 lbs per stud or 31% of full design load. Fire Test: OPL 11710-92851, 9-9-92 (LIMITED LOAD -BEARING) PROPRIETARY GYPSUM BOARD BPB America Inc. - 5/s" ProRocTm Type X Gypsum Panels GYPSUM WALLBOARD, WOOD STUDS One layer 51s" type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to each side of 2 x 4 wood studs 24" o.c. with 6d coated nails, 17/a" long, 0.0915" shank, 1/4" heads, 7" o.c. Joints staggered 24" on opposite sides. (LOAD -BEARING) A Thickness: 47/s" Approx. Weight: 7 psf Fire Test: UL R3501-47, -48, 9-17-65, Design U309; UL R1319-129, 7-22-70, UL Design U314 Sound Test: NGC 2404,10-14-70 GYPSUM WALLBOARD, WOOD STUDS One layer 5/a" type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to each side of 2 x 4 wood studs 16" o.c. with 11/4" Type W drywall screws 12" O.C. Joints staggered 16" on opposite sides. (LOAD -BEARING) EX_. I � - I—. � Thickness: 43W Approx. Weight: 7 psf Fire Test, SWRI 01-4511-619, B-19-92 Sound Test: See WP 8526 (G&H NG-246FT, 7-2-65) 'A I M GYPSUM WALLBOARD, WOOD STUDS One layer type X plain or predecorated gypsum wallboard applied parallel to each side of 2 x 4 wood studs 24" o-c. with 6d coated nails, IN" long, 0.0915" shank, 1/4" heads, 7" o.c. at joints and top and bottom plates and 3/s" beads of adhesive at intermediate ILI_ I studs. Joints staggered 24" on opposite sides. (LOAD-BEARIING) Thickness: 47/e" Approx. Weight: 7 psf Fire Test: FM WP 90,8-21-67 Sound Test: G&H NG-246F� 7-2-65 GA-600-2003 t Contact the manufacturer for more detailed information on proprietary products- . 57