Loading...
20060717105115.pdfED Ni P" DATE: July 17,2006 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 TO: Rocky Sheldon FAX: 206-628-0386 FROM: Ann Bullis, Assistant Building Official RE: Plan Check # 2006-0752 Project: Tenant Irnpro vement Project Address: 21616 76h Ave W, Suites 101 & 102 In reviewing the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please submit 2 sets of revised plans/documents (affected sheets only) to Marie Harrison, Permit Coordinator. I . With this tenant improvement, clarify if suites 10 1 and 102 intended to be combined and function as one tenant space. If they are to function as 2 tenant spaces, show the main and accessible entrance to suite 102. Clarify plans. 2. IBC 1004.1 requires that the largest number of occupants (actual number of occupants or number determined using factors in Table 1004.1.2) be used, Clarify occupant load calcs on Sheet A2. 1. What does "programinatic occupancy load" mean? Please clearly show on the plans the actual vs. calculated occupant load. For example, based on the number of chairs shown on the floor plan, Suite 10 1 will have 50 occupants, which requires 2 exits. Revise calculated occupant load to show gross area of tenant spaces (not including conference rooms) at a factor of 100 (per IBC 1002 gross area includes essentially everything except shafts) plus the conference room occupant load. By my calculations, the occupant load of suite 101 is 39 and the occupant load of suite 102 is 36. Chairs on the floor plan well exceed these amounts. Revise/ ustify. Show on plans if the 1 -hour rating of the roof -ceiling above is the suspended ceiling system or at the underside of the joists above. 4. If the suspended ceiling system is providing the 1-hour fire rating (per item 2 above), where the grid system will be altered, provide the listed and tested 1 -hour suspended ceiling system to be used (grid and panels that have been tested together). Submit the manufacturer's grid and p anel information referencing the specified listing number. S. Provide listed and tested firestopping assemblies for penetrations of fire rated walls and ceilings. 6. A portion of the reception counter must be accessible per ICC/ANSI A 117.1 section 904. Provide a construction detail showing the height and width of the counter for forward or side approach. 7. Dimension the minimum 18" maneuvering distance on pull -side of entrance door next to the reception counter. Dimension the minimum 12" maneuvering distance on the push side of door 1011 A. 8. Per IBC/WAC 3409.6 exception 1, provide upgrades to the existing elements of the accessible route of travel not exceed 20% of the contractor's bid, such as door hardware, restrooms, exterior path of travel to the entrances, etc. Architect to provide a letter stating what existing elements do not meet current accessibility codes, and state what upgrades will be made as part of this project to meettoxceed 20% (including itemized bid showing how the 20% is being met). Show upgrades on the plans. 9. Revise details 1 & 3 Sheet A2.2 for seismic anchoring of partitions to roof or floor structure above to meet IBC 1621.1.2, ASCE-7 section 9.6.2.8.1 for lateral bracing. 10. Revise reflected ceiling plan to show existing and proposed mechanical/HVAC work (listed in contractor's bid), or list as a deferred submittal. Supply and return are required for each occupied area, which is currently not shown on the plans. Page 2 of 2