Loading...
20060794 michel 8 unit- rev comments-20060803091902.pdfCity of Edmonds 121 5"' AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.LIS DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Check #: 20060794 Date: 1 Aug 06 Project Name/Address: Michel 8 Unit Condo; 21207 82nd Ave W Contact Person/Address/Fax: : Rob Michel fax: 778-0896 Reviewer: Lyle Chrisman, Engineering Program Manager Division: Engineering The subject application has been reviewed but cannot be completed until the following items have been addressed/corrected. Please resubmit 3 sets of revised drawings to a Development Services Permit Coordinator. Sheet 1 1. Install cb protection for all surrounding cb's. 2. Indicate existing pavement used for parking at 21215 to be removed. 3. Show existing trees and those to be removed. 4. There is an additional sewer manhole lid immediately south of the one shown on 82"d Ave. The manhole is quite large. Show both lids. 5. Indicate grading within the city right-of-way. 6. Add erosion control fencing along the frontage of the property. 7. Move the rock entrance to the proposed site entrance. The location shown is too close to the intersection and will be difficult to get in and out of. 8. Add a note that grading for the proposed buildings can only go to the finished floor elevation. 9. The proposed c/g on 82" d Ave shall be placed 15' from the right of way centerline. Curb location should align with the flow line of the existing cb at the south end of the site. 10. Adjust entrance radii so flow line matches existing cb on the north side of project entrance. 11. Provide top of curb elevations along the length of the curbing. 12. Provide sufficient existing pavement grade elevations to show flow to the curb line/cb's. DATE, FAXED (Attach fax transmittal) PAGE OF S:\ENGR\PRIVATE DEVELOMENT PROJECTS\REVIEMCOMM-MULTI & LU\2006\20060794 michel 8 unit condo review I.doc Sheet 2 13. Provide street cross sections on 82nd Ave to show existing pavement slope and new pavement slope to curb line. 14. With the existing cb at the north end, being raised, the cb must be changed to a type II because the grade to invert will be 6' or more. In addition, the lid needs to be changed to a solid locking lid. 15. Indicate on the drawing that all the street curbing shall be painted yellow. 16. Show mailbox cluster location and increased sidewalk width accordingly. 17. Footing drains cannot connect to the detention system. Indicate separate lines and connection point of footing drains. 18. Provide invert elevations of the the roof tightlines at the yard basins and slope of the pipes. 19. The control structure cb is not sized correctly to handle the 2.5' detention pipe. 20. Provide additional turn- around at the end of the access road for the end units. 21. Will the trash and recycle containers be kept in the garages? If not show the location of the trash/recyle enclosure. 22. Provide inverts of 4" pipe at cb,72 and cb-3. 23. The extruded curbing shown shall terminate at the property line. Use standard curb and gutter within the right- of-way, including the curb radii. Sheet 3 24. Show the location of the existing sewer laterals to the property line and connection of new lines to those laterals if the existing laterals can be reused. If the lines cannot be reused, show where the laterals will connect to the main. 25. Show new sewer cleanouts on the right-of-way side at the property line. 26. Show water service line location to each unit. Maintain required clearances between utilities. 27. Show location of existing water meters. Will either of the existing meters be used for irrigation? If existing meters will not be reused, place a note on the drawing that the water services must be disconnected and turned off at the main. 28. Provide invert elevations for the sewer laterals and side sewers. Drainage report 29. See attached pdf documents. General 30. Please provide a traffic control plan. 31. Submit an engineers estimate or contractor's bid so the bond amount and inspection fee can be determined. DATE FAXED (Attach fax transmittal) PAGE OF S:\ENGR\PRIVATE DEVELOMENT PROJECTS\REVIEW\COMM-MULTI & LU\2006\20060794 michel 8 unit condo review I.doc 110- . 2 \ � . c E�! i � Lu O O � O � g � �~ W � aa Ed 6 � 5/10/-Q-6 page 1 MICHEL 82nd PLACE WEST CONDO'S 0034 ---------------____________ BASIN SUMMARY BASIN ID: 002EXIST SCS METHODOLOGY TOTAL AREA.......: RAINFALL TYPE....: PRECIPITATION....: TIME INTERVAL....: NAME: 2 YEAR 24 HOUR EXISTING 0.56 Acres TYPElA 1.50 inches 10.00 min ABSTRACTION COEFF: 0.20 TcReach - Sheet L: 26.00 ns:0.1500 p2yr: 31._5-0 S-0-1-923 TcReach - Sheet L: 123.00 ns:0.1500 p2yr: 1.50 s:0.0407 PEAK RATE: 0.07 cfs VOL: 0.03 Ac -ft TIME: 510 min BASEFLDWS: AREA. CN..... TC..... 0.'00 fs PERV , 5 --0."4°3 Acres 85.00 14.6-B :min BASIN ID: 010EXIST SCS METHODOLOGY TOTAL AREA ....... . RAINFALL TYPE....: PRECIPITATION....: TIME INTERVAL....: NAME: 10 YEAR 24-HOUR EXISTENG 0.56 Acres TYPElA 2:00 inches 10.00 min BASEFLOWS: AREA..: CN..... 0.00 cfs PERV , 51 0.'4`0 Acres 85.00 14.68 min ,Abb,1'KAC:'1'lUN C:UEFF : 0,,20 TcReach - Sheet L: =26.00 ns:0.1500 p2yr: 1.50 s:0.1923 TcReach - Sheet L:, 123.00 -ns:0.1500-p2yr: 1.50 s:ff-0407 PEAK RATE: 0.12 cfs VOL: 0.05 Ac -ft TIME: 510 min BASIN ID: 100EXIST SCS METHODOLOGY TOTAL AREA.......: RAINFALL TYPE....: PRECIPITATION....: TIME INTERVAL....: NAME: 100 YEAR 24 HOUR EXISTING 0.56 Acres TYPE 1A 3.00 inches 10.00 min BASEFLOWS: AREA..: CN..... TC..... 0.0 cfs PERV , 0.1-3 Acres 85.00 14.68 min AtS�'1'KAC'1'lUN CUEFF : 0.20 TcReach - Sheet L: 26.00 ns:0.1500 p2yr: 1_50 s-,0.1923 TcReach - Sheet L: 123.00 ns:0.1500 p2yr: 1.50 s:0.0407 PEAK RATE: 0.23 cfs VOL: 0.08 Ac -ft TIME: 510 min IMP 70.1s Acres 98.09 -1-4: b8 min IMP 0 0 . M. Acres 98.00 14.68 min IMP 0.12, Acres 98.00 3-4.58 min MICHEL 82nd PLACE WEST CONDO'S Mao i1HVEIi PC3f?L TA$IlE SIINIMARY____________________ =- e� -A, L., -MATCH INFLOW -STO- --DIS- t PEAT{-> STORAgE lb"e OU T UES IPTI{ki - {8 fi:� {Efs - —fit i�- < i'$ ' � S -d �cf } / 2- YEAR 24 HOUR . _..... _.._..... 9_.-07 Q.ll _ PL {13 415.65 114.513 Cf c`� . 07 100 YEAR 24 HOUR ............. 0.23 0.29 PI Ol 416.99 0 315.55 cf, e� -A, L.,