20060810133605.pdfEDo City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION ESt 18go (425) 771-0220 DATE: August 10, 2006 TO: Jack Hicks shelterform@yahoo.com FROM: Jenny Readwin, Plans Ex4-e RE: Plan Check # 2006-0839 Project: Dawson SFR Project Address: 9016 242"' St During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Site plan submitted is missing some minimum submittal requirements (setbacks from sfr to property lines, roof/cave overhangs, topography, sewer and water lines, North arrow on reduced copy, etc.). See attached sample plot plan checklist for minimum site plan requirements. Please submit 3 revised site plans one no larger than 8 %" x 14" scaled 1"=20'. 2) Show accurate porch configuration on the site plan. Per the plans it curves out front rather than being straight. If they are only steps please still show on the site plan. 3) Elevation views show a deck above the covered porch. How will this be accessed? Show location of proposed deck on the floor plans. 4) Specify on the elevation views the grade slope away from the building. If minimum 6" within 10' is not possible or habitable or useable space is below grade, foundation drainage is required. Provide footing drain detail on foundation sections complying with R405.1 and show required drain locations on the foundation plan. 5) See attached structural comments from city consultant. Respond to each item in writing. e M Eagle Eye Consulting Engineers, P.S. PO Box 523 Olalla, WA 98359 hoytjeter@centurytel.net 360 874 0562 Fax 360 874 0591 To: JoAnne Zulauf City of Edmonds Edmonds, WA 98020 Re: Dawson Residence 9016 242nd St SW Edmonds, WA 98020 Plan Review # 2006-0839 Structure Area S.F. First floor 1604 Second floor 1384 Total 2988 arae 704 otal 3692 Date: 7/31106 EECE # EDM 06-40 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed, prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 4 EECE#: EDM 06-40 Dawson Residence STRUCTURAL COMMENTS General 1. The drawing clearly states tile roofing is going to be used. The lateral analysis submitted has not included this. Resubmit a lateral analysis to account for the higher roof dead load. IBC 1617.5.1 2. Resubmit a gravity analysis to account for the tile roof as specified on the drawings. For example, roof supporting beam mark BM used 15 PSF, which is not conservative for a file roof. Note, not all beams were checked so when resubmitting please verify all design forces. IBC 1671.5 3. The design analysis only used 4 foot high for the floor diaphragm seismic lateral force. The floor system wall below must be included for the floor diaphragm forces not just the wall part above that floor. The walls span from floor to floor and this force will be induced on the horizontal diaphragm. Resubmit analysis to account for this for this force on the diaphragm. IBC 1617.5.2 Sheet 1 1St Floor Plan 4. Engineer of Record (EOR), please clearly dimension all of the shear wall lengths that are required on the drawings. For example, the drawings show the shear wall at the porch to be 5 feet long on one side. The window schedule has the window mark 7, 2 and 1 which adds up to 13 feet. This would make the shear wall only 2 feet long. The analysis used 5 feet for this wall. I assume the window is incorrect and a different window is to be used here, but the drawings specify these windows to be used. 5. Please clearly add the required length of all shear walls on the drawings. Based off the submitted drawings the walls would have to be scaled to verify the length. For example, the shear walls at the library. Based off the dimensions shown there is no way to determine the required length. Please add this information to the drawings in order to complete the lateral review of this structure. Sheet 2 2nd Floor Plan 6. The shear wall schedule requirements on this sheet for the sill plate are different. Which one is the correct schedule to use? This is very important to clearly specify the correct schedule to use for this structure. Please modify accordingly. 7. EOR, please add a detail on the drawing for the hold-down required at the master bedroom. How are the loads being transferred at this level. Page 3 of 4 EECE#: EDM 06-40 Dawson Residence 8. The code requires positive connections for the posts to beams to be specified on the drawings. Currently the drawings do not specify this. For example, what is the J1 connection to post P2? IBC 2304.9.7 Sheet 3 Foundation 1st Floor Frame 9. EOR, please specify the required size of the footing that is to be used under the P3 columns. Also include analysis to justify size used. IBC 106.3 10. The drawings do not show any connection for the P3 column at the base. All columns are required to be positively attached to prevent lateral displacement. This should be clearly specified on the drawings. IBC 2304 11. Please specify the required connections of joist J2 to the house. It isnot clear on the drawings what is required for this connection. Please add this to the drawings. IBC 2304.9.6 12. Please clarify where detail 413 is shown. This is cut at the bedroom 4.1 assume the intent is to have this be section 4B but this is not what is called out on the drawings. Please modify accordingly. IBC 106. 1.1 13. Please submit analysis for the beam mark B7 to justify size specified on the drawings. This was not in the submitted packages. IBC 1603.1 14. Provide analysis and specify the required connection of the concrete baluster. This is required to be a guard rail and resist a force of 200 pound applied in any directions. IBC 1607.7.1 Sheet 4 Roofing 15. There are no details on the drawing for the connection of the column to the Girder members. The drawings are required to specify the required post to girder connection on the drawings. Please add this information to the drawings. IBC 2304.9.7 Additional corrections may be required following receipt of corrections and additional information as requested. Page 4 of 4 EECE#: EDM 06-40 Dawson Residence Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874-0562 between 8:00 a.m, and 5:00 p.m. By; Hoyt Jeter, P.E. President '' V KI PLOUSITE PLAN CHECKLIST ❑ Property owner's name, tax account parcel number and street address. ❑ North arrow designation and Scaled 1"=20'. ❑ Streets, approaches, driveways, sidewalks, alleys, easements (public and private), paved areas, street dedications and adjacent City right- of-way (developed or undeveloped). Show dimensions. ❑ Side sewer stub and proposed sewer lines, water meter location, water service line, gas, cable and phone lines, fire hydrants, telephone poles, utility transformers. ❑ Existing physical features and water courses of any size (i.e., streams creeks, ponds, ditches, etc.). ❑ Dimension all buildings and structures (label them existing or proposed), indicate setback distances, lot area and lot coverage. ❑ Accessory structures and projections; decks, porches, hot tubs, pools, cantilevered structures, bay windows, chimneys, roof overhangs, eave lines, breezeways, patios, sheds, pool mechanical rooms, etc. ❑ Retaining wall or rockery location with typical section detail. (Refer to separate Rockery and Retaining Wall Handouts #B62 & #B63) ❑ Fences existing and proposed. ❑ Building height calculations, average grade, actual height, maximum allowed height (See Handout #B41). Datum point and elevation located off-site (i.e. top of sewer manhole lid, top of fire hydrant, etc.) and lowest footing elevation. ❑ Elevations at four corners of property lines. Topographic lines at two foot intervals. Lot slope and driveway slope. ❑ Impervious surface calculations, existing impervious surface (Pre and Post July 1977) separate from proposed impervious surface. It is the owner/applicant's responsibility to submit a true and accurate plot/site plan to the City. L:ITEMPIBUILDING\HANDOUT ICODES\Handouts Webpage\PLOTPLAN B57.doc Revised 7104 ..... ..... _ .... ......... Property Owner Name #B57 Property Address SAMPLE PLOT PLAN Tax Account Parcel # Scale: 1"=20' +108 +109 IMPERVIOUS SURFACE CALCS (SOLID SURFACES) +106 / � Exist. Building Roof Outline: 2200 sf. (constr. in 1962) : Existing Covered Porch: 75 A. (constructed in 1962) +104 _ Existing Driveway: 610 s£ (constructed in 1987) +102 Existing Patio: 200 sf. (constructed in 1985) Proposed Addition: 440 s£ Proposed Garage: 500 sf. 1 Proposed Deck: 90 s£ HEIGHT CALCS A = +99' B = +107' C = +100' D = +105' AVE GRADE = 102.75' ACTUAL W 123' MAXIMUM =127.75' LOT COVERAGE: 3515 SQ.FT. (26%) LOT AREA: 13,527 SQ.FT. LOTSLOPE; 11% Property Line I g ry \ I -I I- I "fExisffnO Existing25'-011Residence I� iI, 3O13 2000 sq.ft. u;=��°�OC?;� i€�. l I +9� - Q cg •, I £'sik€i%� IPI IN I I e L.Covered Poch +99 Existing •. I — _ !''� _ I I Grade Contours i I` X00 S ft i 1 g147estFootmiElevaroee len � J :_Pro�osed�Deck _ — +100' . - " - " -- - " ,. �� sq`{3 t B Driveway o '0 Slope 6% I +991; :;'1 OOr +1071 rnrIL .; :. S idewa - Water Meter Existin I I I � 'Rocke I Ii r I I I I g ry \ I -I I- I "fExisffnO Existing25'-011Residence I� iI, 3O13 2000 sq.ft. u;=��°�OC?;� i€�. l I M MAIN STREET Telephone Pole ODATUM PT. +100' — Center of Right -of -Way — ss Top of SS Manhole Cover L:ltemp4buiidinglhandoutladdifionlplotvsd7104 _ ATTACHMENT A L:ITEMP1BUlLD1NGUbXND0UT ICODESIHandouts WebpagelPLOTPLAN B57-doC Revised 7104 Q cg •, I £'sik€i%� IPI IN I I e L.Covered Poch `. Existing •. I — _ !''� _ I I Grade Contours i I` X00 S ft i 1 g147estFootmiElevaroee len - J +100' . - " - " -- - " ,. 1 Existing Asphalt Driveway o '0 Slope 6% I :;'1 OOr Ica - rnrIL .; :. S idewa - Water Meter M MAIN STREET Telephone Pole ODATUM PT. +100' — Center of Right -of -Way — ss Top of SS Manhole Cover L:ltemp4buiidinglhandoutladdifionlplotvsd7104 _ ATTACHMENT A L:ITEMP1BUlLD1NGUbXND0UT ICODESIHandouts WebpagelPLOTPLAN B57-doC Revised 7104