20060823093356.pdf08/22/06 11.:10 FAX WJA, PLLC 11002
Structural Review Date 22 Aug 2006
Plan Check No. 2006-0558 Resubmittal WJA Project No. 0407-M
Review by R.V. Stevens
Address 8312 Talbot Road
Owner Mr_ & Mrs. Steve Lovell
Designer Phil Kin Desi in
Engineer JRR Engineering, Inc Ronald K Riach
I have reviewed the Revision Documents and have the following items to be verified:
1. Sheet 1 of 5 Retaining Wall
a. Is wall free to move at top or is wall restrained by roof trusses?
b. If wall is restrained provide connection design and reinforcing on inside face.
c. If wall is un -restrained at top, provide detail to allow for wall deflection.
d. is lap length between vertical bars and dowel bars adequate?
2. Sheet 3 of 5, 8 -Foot Basement Wall
a. Wall reinforcing appears reversed from what is indicated in calculations page 2, verify.
Sincerely,
WJA, PLLC
Architects Engineers i
Land ape h' ct / Ian
r
Ro ert V. Stevens, P.E., S.E.
Senior Structural Engineer