Loading...
20060823093356.pdf08/22/06 11.:10 FAX WJA, PLLC 11002 Structural Review Date 22 Aug 2006 Plan Check No. 2006-0558 Resubmittal WJA Project No. 0407-M Review by R.V. Stevens Address 8312 Talbot Road Owner Mr_ & Mrs. Steve Lovell Designer Phil Kin Desi in Engineer JRR Engineering, Inc Ronald K Riach I have reviewed the Revision Documents and have the following items to be verified: 1. Sheet 1 of 5 Retaining Wall a. Is wall free to move at top or is wall restrained by roof trusses? b. If wall is restrained provide connection design and reinforcing on inside face. c. If wall is un -restrained at top, provide detail to allow for wall deflection. d. is lap length between vertical bars and dowel bars adequate? 2. Sheet 3 of 5, 8 -Foot Basement Wall a. Wall reinforcing appears reversed from what is indicated in calculations page 2, verify. Sincerely, WJA, PLLC Architects Engineers i Land ape h' ct / Ian r Ro ert V. Stevens, P.E., S.E. Senior Structural Engineer CowieORn71vE REcFnVE® AUG 2 2 2006 DEVEL0CpMF-NT SERVICES CTR. OF EDMONDS I yurrE A�SEATTLE, WA gel4 7208.254.2570 r WJA - pg 'l