`~ PLAN REVIEW COMMENTS
BUILDING DIVISION
�St g90 (425) 771-0220
DATE: August 24, 2006
TO: Byung Kim
23726 100 Ave W
Edmonds, WA 98020
FROM: Ann Bullis, Assistant Building Official *7
RE: Plan Check # 06-176 (2006-0630)
Project: Woodway Gas & Mart Change of Use/Remodel
Project Address: 23726 100` Ave W
During re -re -review of the plans for the above noted project, it was found that the following information,
clarifications or changes are still needed. Please submit 2 sets of revised plans/documents to Marie
Harrison, Permit Coordinator by September 11, 2006 (currently under code enforcement action).
1. Previous item la: Clarify site plan if there is a curb at the building walkway within the accessible route
of travel. If there is, a curb ramp is required. Show on plans and provide detail. ICCIANSI Al 17.1
section 406
2. Previous item 2h: The restroom must be accessible and does not meet the turning space requirements of
ICC/ANSI A117.1 sections 603.2.1 and 304. Alteration of the existing restroom is required, unless the
Architect can find that it is technically infeasible (see definition under IBC 3402). If technically
infeasible, provide a letter stamped and signed by the architect (addressed to the Building Official,
Jeannine Graf) explaining why it is technically infeasible to alter the restroom to comply with current
accessibility codes.