2006-0839-1.doc
City of Edmonds
TH
121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221
Website: www.ci.edmonds.wa.us
DEVELOPMENT SERVICES DEPARTMENT
Planning • Building • Engineering
Plan Review Corrections
Plan Check : Date:
# BLD20060839 August 11, 2006
nd
Project Name/Address:
Dawson/9016 242 ST SW
Contact Person/Address/Fax:
Jack Hicks/Fax: 425-6545/e-mail: shelterform@yahoo.com
Reviewer: Jaime HawkinsDivision:Engineering
During review of the subject submittal, it was found that the following information, corrections, or
clarifications would need to be addressed:
1.Provide copies of all recorded easements affecting this lot. You are showing a 20-ft access and utility
easement along the east property line and a 10-ft sewer easement along the west property line.
2.The access easement shown in the site plan is a 20-ft easement. If this easement is serving 1- 2 lots then the
required pavement width shall be a minimum of 12-ft. If the easement is serving 3 – 4 lots then the required
pavement width shall be 16-ft. Please see standard details E2.1 and E2.1.1. You may obtain new and up to
date details in the City of Edmonds website under Development/Engineering.
(www.ci.edmonds.wa.us/engr_dept.stm)
3.Please recalculate the proposed impervious surface. I have calculated the proposed impervious surface to be
at 4,650-sq-ft.
4.Please provide invert elevation for all catch basins, and the detention’s system out-fall.
5.The proposed detention system is shown connecting to a line running within the 10-ft sewer easement. Is this
line a sanitary sewer main line or a storm line? Please indicate accordingly. If this is a storm line please
provide size, and type of material. Is this a private storm or sewer line? If this is a private storm line running
through this property you must first obtain permission from the owner by obtaining or modify any existing
easement prior to obtaining approval of this building permit. A catch basin shall be installed in order to
connect the proposed detention system to the existing storm line that is if this indeed is a storm line.
6.Please show the existing sewer line you are proposing to connect the side sewer. A 6-inch clean out with
locking cast iron lamp hole cover shall be installed at the property line.
7.Please show the water service line from the meter to the house. Note that if poly is used as the material for
the water service line you shall include a tracer wire and it must be grounded at ends, the meter and the
house.
DATE E-MAILED 8/09/06 1 PAGES
8.The standard details you have shown in the Drainage plan are outdated. Please obtain new details and
provide as needed. You may obtain new and up to date details in the City of Edmonds website under
Development/Engineering. (www.ci.edmonds.wa.us/engr_dept.stm)
Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. JoAnne
Zulauf is your Permit Coordinator for this project. Please contact me at 425-771-0220 or by e-mail at
hawkins@ci.edmonds.wa.us if you have specific questions regarding these plan corrections.
DATE E-MAILED 8/09/06 1 PAGES