20060926152907.pdfof �� City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
Est a g90 (425) 771-0220
DATE: September 26, 2006
TO: Guninder Grewal
Fax (206)870-2772
FROM: Jenny Readwin, Plans ExU6
RE: Plan Check # 2006-0989
Project: Pacific Homes SFR
Project Address: 7104 210' St SW
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised
plans/documents (affected sheets only) with a written response to each of the items below to a
Permit Coordinator.
1) Show second floor bedroom 4 window seat cantilever on the site plan to assure it meets
setbacks.
2) Show minimum 100 cfm fan over kitchen stove and specify cfrn rating for all other source
specific fans (50 cfin) including whole house fan (I 10 cfm minimum per energy form)
3) Specify on the elevation views the grade slope away from the building. If minimum 6" within
10' is not possible or habitable or useable space is below grade, foundation drainage is required.
Provide footing drain detail on foundation sections complying with R405.1 and show required
drain locations.on the foundation plan.