20061002162953.pdfo� E� City of Edmonds 0 PLAN REVIEW COMMENTS BUILDING DIVISION �sr 5sao (425)771-0220 DATE: October 2, 2006 TO: Kristin Hanson hansondesi gn(c�r�,hotmail_ com FROM: Jenny Readwin, Plans Exam' er RE: Plan Check 4 2006-1047 Project: Elkins Addition Project Address: 9805234' St SW During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Specify on the elevation views the grade slope away from the building. If minimum 6" within 10' is not possible or habitable or useable space is below grade, foundation drainage is required. Provide footing drain detail on foundation sections complying with R405.1 and show required drain locations on the foundation plan. 2) Shearwalls shown on the architectural sheets do not match the ones shown on the structural sheets. Please coordinate and provide revised calculations if necessary. 3) Provide crawlspace ventilation calculations and show size and location of vents on the foundation plan. 4) According to beam calculations beam must be increased to 63/4" x 18" GLB for L/360 deflection (floor load). Revise beam shown on plans. Also EOR calls out 6x6 posts with ECCQ76 top and CB66 bottom at both ends. Note on plans.