Plan Review Comments – Planning Division
Plan Check #: BLD-2006-1004 (First Review)
Project Name: Tim Weaver SFR
Project Address: 847 Maple Street (RS-6 Zone)
September 18, 2006
Ronald D. Johnson
Architect
rd
19601 23 Avenue NW
Shoreline WA 98177
Phone: 206.546.2288 / Fax: 425.712.0898
Dear Applicant,
I have reviewed the above building permit application for the Planning Division and it was found that the
following information, corrections, or clarifications will need to be addressed before review can continue:
SEPA:
1. (FYI only) Please contact me if your project exceeds 500 cubic yards of cut (plans show 410
cubic yards of material to be removed) and I will be happy to go over the SEPA process with you,
which will include an Environmental Checklist, an Adjacent Property Owner’s (APO) list, and a $420
review fee.
Setbacks:
2. (FYI only) The minimum rear setback in the RS-6 zone is 15 feet and the site plan shows
20 feet. You are at the maximum lot coverage permitted so this will likely not affect your plans, but
if you could redline the site plan to show the rear (north) setback line at 15 feet it would be
appreciated. Or, I will do it when you resubmit (either way is fine with me).
Height Calculations:
3.
Roof Deck:
a. Sheet 8 of 13 says there will be a 42” half wall on the roof deck. Sheet 3 of 13 says
that the roof deck elevation is 262.5 – I just wanted to confirm that the 3.5’ half wall does not
exceed the maximum height limit. It’s not shown on the elevation so I assume that the half wall
is not higher than the ridgeline but I just wanted to make sure – please respond in writing.
Height Rectangle:
b. No need to include the proposed deck in the height calculations because it is
uncovered and the eaves are less than 30 inches. Please move point C further south, point B
further south and east, and point A further east – just so they enclose the covered building
footprint, and revise height calculations accordingly. If it turns out that the smallest rectangle that
encloses all of the building footprint puts any of the points off site, please review the definition of
Height below and recalculate these points accordingly.
ECDC 21.40.030.B:
“Average level” shall be determined by averaging elevations of the downward projections
of the four corners of the smallest rectangle which will enclose all of the building, excluding a maximum of 30
inches of eaves. If a corner falls off the site, its elevation shall be the average elevation of the two points
projected downward where the two sides of the rectangle cross the property line. (See subsection (C)(1) of this
section for exceptions to this rule.)
Page 1 of 2
Thank you for your cooperation. Please redline plans or submit three sets of revised plans/documents
(affected sheets only) with a written response to each of the above items. Please make all submittals to
the Development Services Permit Coordinator (Marie Harrison) Monday through Friday, 9am to noon or
1pm to 4pm. If you have any questions, please do not hesitate to contact me at (425) 771-0220, extension
1778. I look forward to working with you on this project.
Sincerely,
CITY OF EDMONDS
Gina Coccia, Planner