Loading...
20061010082552.pdfCity of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October 10, 2006 TO: Chris Amonson TGB Architects Sent via e-mail FROM: Ann Bullis, Assistant Building Official (!�07 RE: Revisions to Permit #2005-0962 & 2006-0559 Project: Revision — Exterior ramps for accessible exit from Suite 110 Project Address: 2191176' Ave W During review of the revision for the above noted project, it was found that the following information, clarifications or changes are needed. Please submit 2 sets of revised plans (affected sheets only) to Marie Harrison, Permit Coordinator. 1. Revise ramp handrail height: 34" minimum to 38" maximum measured vertically to top of handrail. 2. Edge protection is required at each side of the ramp per ICCIANSI Al 17.1 Section 405.9. The 17" mid . rail noted on the plans is not a permitted edge protection. cc: Colin Winters, sent via e-mail