20061012095722.pdfo ' �� City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION t. Is 9'3 (425) 771-0220 DATE: October 12, 2006 TO: John Carter Woolen Fax (206)784-9809 FROM: Jenny Readwin, Plans Exam' er RE: Plan Check # 06-148 Project: Hadfield SFR Project Address: 509 6t' Ave S. During re -review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the above items to a Permit Coordinator. 1) —17)ok 18) Will need prior to permit „issuance. Still need signed farm. Special inspections are required for the following. Complete the enclosed special inspection agreement signed by the owner, the general contractor and the special inspector and submit to the City for approval prior to issuance. A separate form is required for each separate special inspector. • Excavation/grading/site preparation • Soil Bearing verification • Placement of fill and compaction • Foundation drainage • Rockery/Retaining wall Construction including drainage • Wall backfill • General Site monitoring during wet weather construction • Temporary and final erosion control • Structural steel (including high strength bolting and field welding) • Concrete construction • Masonry • Expansion bolts and expansion inserts • Wood shear wall system as noted on sheet S1.1 note 11B 19)S ee attached third comment letter. See additional comments form City's structural consultant attached. See attached structural comments from city consultant. Respond to each item in writing. 20) ok 21) ok Eagle Eye Consulting Engineers, P.S. PO Box 523 Olalla, WA 98359 hoytjeter@centurytel.net 253 857 4151 Fax 253 857 5759 To: Swenson Say Faget 2124 3`d Avenue STE 100 Seattle WA 98121 Re: Hadfield Residence 506 6t' Avenue Edmonds, WA Plan Review # 20060619 ( OLD 06-148 number) EECE # EDM 06-18 (3) Third Comment letter Structure Area S.F. Lower Floor 1048 Main floor 1075 Upper floor 1824 Total 3947 arae 955 Total 4902 Deck second floor 141 Roof Deck 286 Grand total C 5329 3947 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 3 STRUCTURAL COMMENTS Sheet S2.3 Upper Floor Framing Plan 1. 4. 10. EOR please provide detail for the attachment of the column above (4x4) at the base. How is this connected to the floor system? Please add this information on the drawings. IBC 2304.9.7 Response states see updated drawings but nothing has been modified. Please modify accordingly. This still has not been modified or unable to find where the changes have been made to the drawings. Please clarify where the information is clearly specified what the required connection shall be. 2. 7. 13. Plan Note 4 states different column caps to use. Please clearly specify which is required for which case. Nothing has been changed on the drawings. Please clarify how this was addressed. This still has not been addressed appropriately. The drawings should clearly state the required post cap to use in each case. The contractor is not a licensed professional and should not be making engineer judgments but the drawings should clearly indicate which hanger to use where. Please modify drawings to state the required hanger to use.. 3. 9. 15. Please provide detail for the support of the 5-114X11.7/8 PSL at grid line D. The response state see updated plans but the plans are not updated. Please modify drawings and resubmit. This still has not been addressed. Sheet S3.1 Framing Details 4. 11. 11. Justify by analyses that the slab will resist the sliding forces for the retaining walls. The safety of factor shall be 1.5. Note the slab is only 4 " thick and design analysis is required to justify the 4" slab will resist this forces. IBC 1806.1 Analysis still has not been submitted for this item. Just state the 4" slab will act as a compression element to transfer the sliding force into passive bearing on the soil is not sufficient. Please also note at the elevator pit there will not be slab as assumed in the analysis. Analysis is required to be submitted to justify. 5. Detail 4: EOR please clarify the required base plate size. The note state "base plate per IS_ or 3/4" non shrink grout" Sheet S4.2 Framing Details 6. Analysis is still required is still required to show the stitched member will transfer the loads. Also the proposal being submitted has not been adopted for the 2003 IBC. Please note single 3X or clearly submit analysis to justify at least equivalent. 12. 18. Shear wall Schedule 12: Code requires 3X member at abutting panel edges. Please modify note 4 to state single 3 X member and not double stud. IBC table 2306.4.]footnote i. (Also Detail B to show 3X member). The city will have to Page 3 of 3 accept the APA submitted in the response. Also analysis must be submitted to show the shear will transfer with the double stitched together. Just stating to stitch together is not sufficient. This has not been submitted and must be submitted to show the forces will be able to transfer the forces. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (253) 857-4151 between 8:00 a.m. and 5:00 p.m. By: Hoyt Jeter, P.E. President