20061023155345.pdfo� EDS City of Edmonds =r,Jj PLAN REVIEW COMMENTS BUILDING DIVISION �Sf. 109 , (425) 771-0220 DATE: October 23, 2006 TO: Warren LaFon warrenlafon@earthlink.net FROM: Ann Bullis, Assistant Building Official RE: Revision to Permit #2006-0590 Project: McCormick — Change of Use Project Address: 635 Paradise Lane During review of the revised plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please submit written responses to the comments below, including where changes can be found on the plans, and 2 sets of revised plans/documents (affected sheets only) to Marie Harrison, Permit Coordinator. Ventilation must be provided either mechanically or with natural ventilation for the proposed office space in the storage addition in accordance with the State Ventilation Indoor Air Quality Code. a. Natural ventilation: Provide in each room or area at the rate 4% of the floor area. Show the calculations on the plans. OR b. Mechanical ventilation: Provide outdoor air at the rates specified in VIAQ Table 3-4 (based on the occupant load established for the building) to each room or area. The system must be balanced (supply and return/exhaust). Provide mechanical plans and calculations showing compliance. Provide manufacturer's specs for the mechanical units to be installed. 2. Exterior exit from storage area must now be accessible. Clarify that there is an accessible path of travel from the exterior door to the public way. 3. Note on the plans if the office will be heated. If so, specify the source of heat, provide Non -Residential Energy Calculations, and show wall, floor and ceiling insulation. 4. Provide calculation to show that the existing concrete slab will support the interior wall supporting the ceiling joists. Is the owner intending to use the area above the office for storage? If so, clearly note on the plans and design the ceiling joists for 125 psf live load (light storage). If not, clearly note this on the plans as well. 5. On detail 2/A2, specify the ceiling finish material type and thickness. 6. Window adjacent to door must be safety glazed. Please note on plan.