Loading...
20061120115731.pdfa� Eng City of Edmonds O PLAN REVIEW COMMENTS - BUILDING DIVISION (425) 771-0220 DATE: November 20, 2006 TO: Gerlach Construction, Inc. gerlacheonst@msn.com FROM: Jenny Readwin, Plans Ex ne RE: Plan Check # 2006-1255 Project: Cannon Interior Remodel Project Address: 205 Highland Drive During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) On the site plan show location/area of proposed remodel. 2) Provide complete main floor plan showing entire house. 3) An additional smoke detector is required in the hallway outside the bedrooms. Note on plans. 4) Specify source specific exhaust fans are minimum 50 cfin. 5) Provide general roof framing plan to verify that all walls being removed are non-bearing. 6) Clarify bedroom window sill height is maximum 44". Two dimensions are given on the floor plan and it is unclear if they meet the minimum sill height requirements.