20061120150119.pdfa ED City of Edmonds PLAN REVIEW COMMENTS BI JILDING DIVISION �St 1890 (425) 771-0220 DATE: November 20, 2006 TO: Luke Hagler Charter Construction, Inc. FAX: 206-382-0450 FROM: . Ann Bullis, Assistant Building Official 5ft�_ RE: Plan Check ##2006-0991 Project: Third Avenue Plaza -- Reroof Project Address: 120 P Ave S During re -review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please submit revised plans/documents to Theresa Umbaugh, Permit Coordinator. 1. Previous Itemla: The City did not receive letter from the architect stating the documents are in conformance with HB1848 (RCW 64.55). Please provide. 2. Previous Item 2: This correction still stands. Also, in response to the architects last paragraph, the plans provided for reference for the exterior wall repair were a copy of the original building plans from permit #1993-0593. No other building plans were provided. 3. Previous Item 3: The type of construction for this building is Type VA (1 -hour), please revise the plans. With regards to the architect's discussion in his letter on this item, during review of the exterior wall repair under Permit #2004-0724, Mr. Soltner made the same argument for fire resistive substitution under the 1991 UBC. After researching City archive records, the City responded to him at that time that the building is only sprinkled on the residential floor and with an NFPA-13R system which did not qualify for fire resistive substitution. He then resubmitted details for 1 -hour fire rated exterior walls for a V 1 -hour building. 4. Previous Item 7: Still need written contractor's bid for project.