20061122102505.pdfQF ELIC City of Edmonds O PLAN REVIEW COMMENTS BUILDING DIVISION �Sf t s9° (425) 771-0220 DATE: November 22, 2006 TO: PMA Development Services Fax 425-672-7998 FROM: Jenny Readwin, Plans Exine RE: Plan Check # 2006-1189 Project: PMA SFR Project Address: 1128 Viewland Way During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Provide top and bottom wall elevations for existing rockery to verify that it is not supporting a surcharge from the driveway. 2) Lot exceeds 15% slope so a complete soils report complying with IRC chapter 4 is required. See attached for minimum report requirements. Also, foundation recommendations must be incorporated into the foundation plan. Special Inspections will be determined once report is received. 3) According to our maps there is a access easement to the South of the property. Please show on the site plan. 4) Show how island sink will be vented through the roof or with a loop vent as permitted by UPC 909.0.Air admittance valves are not permitted unless first approved by the Building Official 5) Show size and location of attic access. 6) R403:1.3 requires all vertical rebar to have a standard hook. Revise all foundation details to reflect. 7) Specify on the elevation views the grade slope away from the building. If minimum 6" within 10' is not possible or habitable or useable space is below grade, foundation drainage is required. Provide footing drain detail on foundation sections complying with R405.1 and show required drain locations on the foundation plan. 8) See attached structural comments from city consultant. Respond to each item in writing. Eagle Eye Consulting Engineers, P.S. PO Box 523 Olalla, WA 98359 hoytjeter@centurytel.net 360 874 0562 Fax 360 874 0591 To: JoAnne Zulauf 121 5th Avenue Edmonds, WA 98020 Re: PMA Construction 1128 Viewland Way Edmonds, WA 98020 Plan Review # 2006-1189 Structure StatFg4''y''yyyd Are2 S. . Lower Floor 2550 Main Floor 2988 Total 5538 Garage 1117 Total 6655 Deck Above 30' Family room 288 Deck above 30' dining room 84 Grand total 7027 November 9,2006: EECE # EDM 06-63 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 3 EECE#. EDM 06-63 PMA Construction 2006-1189 STRUCTURAL COMMENTS Sheet A4 FOUNDATION PLAN: 1. Architect of Record (AOR), please specify the required post connection to the foundation. The drawings state post and connection per plan. The post is specified on sheet A5 but not the connections. 2. AOR, please specify the size of the footing required to support the covered entry post. 3. AOR, please provide an analysis for the continuous footing to support the post. For example, the post that supports the 3-I/2X 11-718 flush beam supporting the family room joists. Per a check of analysis the allowable bearing pressure 1500 psf. Sheet A5 LOWER FLOOR PLAN: 4. AOR, please specify the required post at the corner of the garage that supports the 5-14X16-12 PSL. Sheet A6 MAIN FLOOR FRAMING PLAN: 5. Please provide a detail and analysis for th �of the ledger to the house that supports the deck framing. 6. Engineer of Record (EOR), please modify the joist call out to match current the joist designation. The drawings state TSI 550 but there is not a 550 but a 560. 1 assume this is the one intended to use. To assure the correct one is used please note this designation. 7. AOR, please specify the required post to support the 5-1/8X13-1/2 glu-lam beam. This also should include the required connections (this occurs at all the deck locations). 8. AOR, please specify the required connection for the 2x12 joist to the 5-1/8X13-1/2 flush beam. Details are for joist bearing on the beams but in this case a joist hanger will be required (this occurs at all the deck locations). 9. AOR, please specify the required joist hanger to use for the 11-7/8 TH 550 (560) to connect to 5-114X16 PSL at the three car garage. 10. AOR, please specify the required connection of post to support the 5-114X16 PSL at the garage. Page 3 of 3 EECE#: EDM 06-63 PMA Construction 2006-1189 Sheet A8 ROOF FRAMING PLAN: 11. AOR, please specify the required post to support the 5-118X9 glu-lam beam. This also should include the required connections (this occurs at all the deck locations). 12. AOR, please provide calculations to justify a 6x8 header to support the framing over the dining room. 13. AOR., please provide calculations for the header over the master bathroom and master bedroom window supporting the roof trusses. Sheet 5-2.0 STRUCTURAL DETAILS: 14. EOR, please clarify how the spacing of the reinforcement steel on the drawings of 16" OIC was determined when the analysis states 44 @ 12". Please clarify on the response. 15. The drawings state 100 psf surcharges, for the design of retaining walls, is required to be used but the analysis submitted appears not to use the surcharge. Please clarify how this was accounted for in the design of the walls. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874-0562 between 8:00 a.m. and 5:00 p.m. By: Hoyt Jeter, P.E. President SOILS INVESTIGATION AND/OR REPORT (Cont.) The classification of bearing soil at the site must be determined and called out on the plans. The following information from IRC Table 8401.4.1, will assist individuals in determining the soil classification of the building site. The Building Official may require this classification to be made by a 'Washington State licensed Geotechnical Engineer or Engineering Geologist in a written report when soils are not adaptable to conventional spread footings or if allowable foundation and lateral pressures do not meet the values set' forth in the table below. The allowable foundation .and lateral pressures may not exceed the values in this table, unless data to substantiate the use of higher values is submitted. Sidehiil or steep - slope construction .,IS NOT considered conventional construction and soils reports are required for lots with 15% or more slope, unless d_etemtined unnecessary by the Building Official. For more specific and technical information on soil capacity, foundation design and construction components, refer to IBC Chapter 18 and IRC Chapter 4 or contact a professional engineer. TABLE R401A.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIAW Far Sl: t pound per square foot= 0.0479 kN/m2. a. When soil tests are required by Section 1,401.4, the allowable bearing capacities of the soil shall be part of the recommendations. b. Where the building official de€ermines that in-placc soils with an allowable bearing capacity of less than 1,500 ps£ are likely to be present at the site, the allowable bearing capacity shall be determined by a soils investigation. When soils reports are required, they shall include the following: 1. A plot plan showing the location of test borings and/or excavations. 2. A complete record of the soil samples. 3. A record of the soils profile. 4. Elevation of the water table, if encountered. 5. Recommendations for foundation type and design criteria, including but not limited to: bearing capacity of natural or compacted soil; provisions to mitigate the effects of expansive soils; ruitigation of the effects of liquefaction, differential settlement an carrying soil strength, the effects of adjacent loads, and foundation drainage. 6. Expected total and differential settlement. 7. Pile and pier foundation information in accordance with IBC Section 1808.22. 8. Special design and construction provisions for footings or foundations founded on expansive soils, as necessary. 9_ Compacted fill material properties and testing in accordance with IBC Section 1803.5. NOTE: Report recommendations shall be incorporated into the foundation design 4. DRAINAGE PLAN (See Handout ##E72) Development of over 2,000 square feet of new impervious area since July 1977 requires an on-site drainage, system. Impervious area includes: building pad with eave overhangs, paved or graveled areas, solid surface decks, patios, walkways, breezeways, awnings, accessory structures, sidewalks, and driveways. Submit three .(3) -drainage plans, scaled 1"-20', showing all impervious area with square footages as well as the location of the proposed drainage detention system. Attach three (3) copies of the'drainage worksheet (See Handout #E72). Note: The plan must provide for temporary and permanent erosion control and rnlrst include footing drain details. L_tTEMPBU1LDINGUTANDOUT ICODES\SFR B73 -DOC Revised 5106 LOAD-BEARING PRESSU" CLASS OF MATERIAL { uunds per square foot Crystalline bedrock 12.000 Scdime,maa and foliated rock 4,000 Sandy gravel and/or gravel GW and GP) 3,000 Sand, silty sand, clayey sand, silty gravel and clayey gravel SW, SP, SM, SC, GM and GC) 2,000 Clay, sandy clay, silty clay, clayey silt, siltand'sandy silt (Cl, ML, Mil and CH) 1,500, Far Sl: t pound per square foot= 0.0479 kN/m2. a. When soil tests are required by Section 1,401.4, the allowable bearing capacities of the soil shall be part of the recommendations. b. Where the building official de€ermines that in-placc soils with an allowable bearing capacity of less than 1,500 ps£ are likely to be present at the site, the allowable bearing capacity shall be determined by a soils investigation. When soils reports are required, they shall include the following: 1. A plot plan showing the location of test borings and/or excavations. 2. A complete record of the soil samples. 3. A record of the soils profile. 4. Elevation of the water table, if encountered. 5. Recommendations for foundation type and design criteria, including but not limited to: bearing capacity of natural or compacted soil; provisions to mitigate the effects of expansive soils; ruitigation of the effects of liquefaction, differential settlement an carrying soil strength, the effects of adjacent loads, and foundation drainage. 6. Expected total and differential settlement. 7. Pile and pier foundation information in accordance with IBC Section 1808.22. 8. Special design and construction provisions for footings or foundations founded on expansive soils, as necessary. 9_ Compacted fill material properties and testing in accordance with IBC Section 1803.5. NOTE: Report recommendations shall be incorporated into the foundation design 4. DRAINAGE PLAN (See Handout ##E72) Development of over 2,000 square feet of new impervious area since July 1977 requires an on-site drainage, system. Impervious area includes: building pad with eave overhangs, paved or graveled areas, solid surface decks, patios, walkways, breezeways, awnings, accessory structures, sidewalks, and driveways. Submit three .(3) -drainage plans, scaled 1"-20', showing all impervious area with square footages as well as the location of the proposed drainage detention system. Attach three (3) copies of the'drainage worksheet (See Handout #E72). Note: The plan must provide for temporary and permanent erosion control and rnlrst include footing drain details. L_tTEMPBU1LDINGUTANDOUT ICODES\SFR B73 -DOC Revised 5106