20061122113321.pdfof� City of Edmonds E o PLAN REVIEW COMMENTS BUILDING DIVISION Fsr. i 89� (425) 771-0220 DATE: November 22, 2006 TO: Ralph J and Lee Anne Malott latnalott@u.washington.edu FROM: Jenny Readwin, Plans Exami er RE: Plan Check 4 2006-1228 Project: Malott Garage Project Address: 1130 Sierra Place During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Provide roof framing plan showing rafters, beams, ceiling joists, etc. See attached sample plan. 2) By my calculations rafters and ridge beam are over spanned. Provide calculations stamped and signed by a Washington State Licensed Professional Engineer. 3) Provide section view from the foundation through the roof for the garden window area to show how this area frames into the garage. 4) Specify use of space for window area as well as main area on the plans (i.e sunroom, garage, etc.). Also, note if areas are heated or unheated. 5) Foundation as shown on the section detail does not meet conventional construction. Provide calculations from a Washington State Licensed Professional Engineer to verify existing construction is adequate. 6) Exterior walls do not meet minimum wall bracing required by IRC 602.10. Provide lateral calculations stamped and signed by a Washington State Licensed Engineer. 7) Section detail of building notes 6" minimum wood -earth separation at the bottom of the siding, however, from the pictures it looks like some areas do not meet this. Note on the plans that the grade will be changed to meet thing. 8) Specify how the site drains away from the building to prevent water in contact with the wood siding and sill plate (i.e. slope). Also, any wood in contact with concrete must be pressure treated. Clearly show on the plans how these issues will be resolved. Truss Example: Manufactured trusses at 24" o.c_ Truss drawings must be stamped and signed by State licensed Professional Engineer and prov"rded to the Building Inspector at framing Inspection_ All trusses shall be anchored to the bearing walls with approved framing,clips_ Rafter Example: 2x8 HP#2 at 24" o.c. Ali rafters shall be anchored to the bearing walls with approved framing clips_ Sample Roof Plan Tri sp ----------------------------- ----- L ATTACHMENT F L:Itemplbuildinglhandouttgaragelroofpin.vsd — 8104