Loading...
20061129111820.pdfOF ED4 City of Edmonds lvi Od PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: November 29, 2006 TO: Jose Cadiz FAX: 206-364-0934 FROM: Ann Bullis, Assistant Building Official RE: Plan Check #2006-1242 Project: Greenberg Mixed Use Building -- Plumbing Project Address: 155 3r1 Ave S During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please submit 2 sets of revised plans/documents to Marie Harrison, Permit Coordinator. 2 0 6 Items 2 and 4 from the City's Plumbing Permit Submittal Requirements are missing from the permit application. Please provide. On the schematic plans, show the main building shut off, pressure reduction valve, shut off for each unit, and dishwashers. Show the location of the water heaters on the floor plans, and note whether they are gas or electric. If gas, show how combustion air will be provided per IFGC 304 (also see prohibited locations in WAC 51-56 section 505.1 (State amendment to UPC)). Show how water heater will be vented to the outside and maintain 1 -hour fire ratings at floor - ceilings and walls (including shaft, lined joist bays, soffits, etc.). Hilti fire stopping submittal: a. The Hilti fax notes that this is for "ABS through gyp floor", however the UL assembly (W -L-2340) is for plastic pipe through a gyp wall assembly, not a floor. b. The assembly is also for a steel stud wall, while the approved plans show no steel stud walls, except for the steel runners at the 1 -hour shaft detail. On the plumbing plans, show where this fire stopping assembly applies within the building. c. Provide listed and tested fire stopping assemblies for all penetrations of 1 -hour rated floor -ceiling, roof -ceiling, and wall assemblies that match the construction shown on the approved plans and type of pipe penetration. Respond to Engineering Division comments dated 11128106. B55 City of edmonds development information �n. I sao Plumbing Permit Submittal Requirements PERMIT REQUIRED: A permit is required to install, alter, repair, relocate, or replace any portion of a potable or waste plumbing system. Including gas hot water tank replacement, water service line repair or replacement, propane tanks, and to install or alter gas piping. EXEMPT WORK: The clearing of stoppages or the repairing of leaks in drains, pipes, valves, vents or fixtures, and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes or fixtures. CODES: Uniform Plumbing Code (Current Edition) International Fuel Gas Code (Current Edition) LPG per 2001 NFPA-58 and 2002 ANSI 2223.1/NFPA-54 FEE: Base fee $30 plus additional fees based on.the number and type of plumbing fixtures plus $15 City surcharge fee SUBMITTAL REQUIREMENTS FOR NEW INSTALLATIONS: I. Plumbing Fixture Schedule Form (See Handout #B, attached) 2Q On a scaled floor plan show the following: a. Drain, Waste and Vent piping layout; sizing, slope and pipe material b. Potable water line layout, sizing and pipe material c. Fixture unit and flow calculations to support line sizing 3. Cross connection devices are required on all direct connections to the potable water system. Specify all fixtures that require cross connection devices (i.e., ice machines, soap ejection systems, beverage dispensers, boilers, etc.) and note the make and model of each device. Indicate the location and cross connection device for premise isolation 5. Manufacturer's specifications for equipment such as sump pumps, ejector pumps, water heater boosters, etc. 6. Gas piping layout, sizing and pipe material, pipe sizing calculations, maximum design operating pressure and location of pressure regulators 7. For Commercial and Multifamily projects, provide Listed and Tested Fire Stopping Assemblies NOTE: THE PURPOSE- OF THIS HANDOUT IS TO ASSIST THE PUBLIC IN COMPLYING WITH DETAILED PERMIT SUBMITTAL REQUIREMENTS. IT IS NOT A COMPLETE LIST OF PERMIT OR CODE REQUIREMENTS AND SHOULD NOT BE USED AS A SUBSTITUTE FOR APPLICABLE LAWS AND REGULATIONS_ IT IS THE RESPONSIBILITY OF THE OWNERIDESIGN PROFESSIONAL TO REVIEW THE SUBMITTAL FOR COMPLETENESS AND APPLICABILITY TO OTHER CODES. ONLY COMPLETE APPLICATIONS WILL BE ACCEPTED BY THE CITY FOR REVIEW_ LITEMPIBU1LDiNGIHANDOUT ICODES/PLUMBING B55 8105