2006-1189_PMASFR-3rd.doc CE ITY OF DMONDS th 121 5 Avenue North • Edmonds, WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www.ci.edmonds.wa.us DSD: P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING Plan Review Comments – Planning Division Plan Check #: BLD-2006-1189 (THIRD Review) Project Name: PMA Development Services – New SFR Project Address: 1128 Viewland Way (RS-12 Zone) February 21, 2007 Mike Arnim PMA Development Services rd 19400 33 Avenue West – Suite 200 Lynnwood WA 98036 Phone: 425.775.1591 | Fax: 425.672.7998 Dear Applicant, I have reviewed the above building permit application for the Planning Division and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: 1. SEPA/Grading: Please provide a response in writing.  11/20/2006 Comment: A SEPA DNS was issued with the short plat for grading, which was not anticipated to exceed 3000 cubic yards. Please let me know how much grading has already been done with the plat improvements (broken down in to amount of cut and fill). Please also verify the amount of cut and fill for the building permit – the site plan shows 390 cubic yards (please break down into cut and fill).  01/29/07 Comment: If you plan to exceed 3000 cubic yards of grading, which was approved with your original SEPA determination, we’ll need to issue an addendum to the original determination. Please submit a grading breakdown and request for an addendum which outlines the grading details of the project. Please submit this verbiage as soon as possible so as not to hold up the rest of the project.  02/21/07 Comment: You responded, “Not over 3,000 cyds,” however the Engineering Division has calculated that you will need to grade well over 3,000 cubic yards. They have estimated that in addition to the 3,000 to be done with the short plat improvements, that grading for the building pads will be approximately 750 cubic yards (an over-estimate, due to the unknown grading of future “Lot 1”). Because we issued a DNS for 3,000 cubic yards, we need to do a “SEPA Addendum” to allow grading in excess of 3000 cubic yards. At your earliest convenience, please provide grading estimates (cut and fill) for both the civil improvements that are to be done with the short plat and for the two new building pads – to cover the entire process – and please slightly over estimate. I will simply need a statement in writing that details the grading plans – please be as specific as possible. Thank you for your cooperation. Please redline plans or submit three sets of revised plans/documents (affected sheets only) with a written response to each of the above items. Please make all submittals to the Development Services Permit Coordinator (JoAnne Zulauf) Monday through Friday, 9am to noon or 1pm to 4pm. If you have any questions, please do not hesitate to contact me at (425) 771-0220, extension 1778. I look forward to working with you on this project. Sincerely, CITY OF EDMONDS Gina Coccia, Planner Page 1 of 1