20061195 edmonds prof ctr.doc City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Comments Plan Check : Date: # 20061195 8 Dec 06 Project Name/Address: Edmonds Professional Center Contact Person/Address/Fax: fax/email : : Reviewer: Division:Engineering Lyle Chrisman, Engineering Program Manager The subject application has been reviewed but cannot be completed until the following items have been addressed/corrected. Please resubmit 3 sets of revised drawings to a Development Services Permit Coordinator. General: 1.Where will patients park if all parking stiping is being removed? How will handicap gain access to the bldg from the east? Sheet A1.7 2.Attach this sheet to the civil drawings. Sheet A 1.1 th 3.Existing main entrance off 210 shall remain commercial type. Existing parking lot to the west shall be changed to a commercial entrance and the new parking lot shall have a commercial type entrance per City standard detail E 2.27. 4.Annotate the parking stall depth (16.5’) on the drawing. 5.Be sure this site plan matches the civil site plan. Sheet C 3 th 6.The existing commercial type entrance from 210 St is to remain as commercial. The new parking lot shall have a commercial type entrance. 7.Entry width to parking lot shall be a minimum of 24’ wide. Indicate width on drawing. 8.Dimension the new parking lot and include stall width and depth and spacing between perpendicular parking stalls. 9.Is the new rockery on the west side of the new parking lot really rockery or modular type block wall? __________________(Attach fax transmittal) DATE FAXED PAGE ____ OF ___ C:\\Users\\cockrum\\AppData\\Local\\Temp\\20061195 edmonds prof ctr.doc_153908\\20061195 edmonds prof ctr.doc 10.Where do the new wall drain connect to? 11.Provide an enlarged detail of the stair construction that leads from the new parking lot to the lower existing parking. 12.Label the symbol for the new sewer ejector pump (located on the west side of the new addition). 13.Indicate the distance between the new curbing in the vicinity of the west entrance. 14.Provide a larger detail drawing of the steps to the new upper parking lot. Sheet C4 th 15.With the upper existing parking lot off 210 St SW being enlarged, the existing detention system needs to be enlarged to accommodate the new impervious surface in that area. 16.Provide drawing a details for the new sewer ejector system. Label its location and indicate where it connects to the building sewer line. 17.Sleeve the storm pipe that goes under the rockery. 18.There is insufficient cover for the proposed 8” pipe that goes through the new portico. Change the pipe material from pvc to d.i.p. Sheet C5 th 19.The curb and gutter to be installed on 210 St shall be the type A standard 18” curb and gutter (detail E2.8). 20.Ladder in the type II cb’s shall be polypropylene. 21.Change the driveway entrance from residential to commercial. 22.Indicate where the sidewalk ramp detail (as shown) will be located. The curb ramp at the parking lot entrances shall match as noted the particular driveway entrance detail. 23.General notes; a.note 1 and 12: Change 2002 to “current edition” b.delete note 7 c.note 12: change ‘or as directed by the City of Edmonds’ to “and City of Edmonds Standards” Storm Drainage report 24. Comments, if any will be forwarded no later than Dec 13, 2006. General 25. Provide a detailed cost break down (engineer’s estimate or contractor’s bid) for all site work both on site and off site so the engineering inspection fee and bond amount can be determined. __________________(Attach fax transmittal) DATE FAXED PAGE ____ OF ___ C:\\Users\\cockrum\\AppData\\Local\\Temp\\20061195 edmonds prof ctr.doc_153908\\20061195 edmonds prof ctr.doc __________________(Attach fax transmittal) DATE FAXED PAGE ____ OF ___ C:\\Users\\cockrum\\AppData\\Local\\Temp\\20061195 edmonds prof ctr.doc_153908\\20061195 edmonds prof ctr.doc