20061227100207.pdfof E� City of Edmonds O PLAN REVIEW COMMENTS BUILDING DIVISION L>Sr i ago (425) 771-0220 DATE: December 27, 2006 TO: Vince Norberg tnicholson@hertz.com FROM: Jenny Readwin, Plans Exam ner RE: Plan Check # 2006-0250A Project: Nicholson Revision Project Address: 703 Driftwood Ln During review of the above noted revision, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the above items to a Permit Coordinator. 1) Hobby room has a closet therefore it is considered a sleeping room and must have a smoke detector and complying egress. Either completely remove closet or provide complying egress window/door. If openings are made in shearwalls provide revised engineering stamped and signed by Engineer of Record. Also note, egress openings can not open into garage areas.