Loading...
20061382 Nguyen SFR.doc City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Corrections Application : Date: # bld20061382 February 8, 2007 Project Name/Address: Nguyen / 8555 Talbot Rd Contact Person/Address/Fax: Cramer Construction / e-mail: colincramer@hotmail.com Reviewer: Jeanie McConnellDivision:Engineering During review of the subject submittal it was found that the following information, corrections, or clarifications will need to be addressed: 1.Provide an accurate, clear detail of the control structure risers/orifices and invert elevations for each on the drainage plan. 2.Provide RIM and invert elevations at CB #4. 3.Indicate how the driveway surface water runoff will be collected and distributed to the storm detention system. 4.Show the footing drain connection to the outfall of the storm detention system. Connection must be made on private property. 5.Show the existing edge of pavement on Talbot Rd. 6.Indicate driveway surface material on the plans. Edmonds Community Development Code section 18.80.060 requires driveway approaches to be paved from the edge of the existing street a distance of 20 feet or to the edge of the property line, whichever is greater. 7.Show the limits of the sewer easement on the plans. I have attached for you a copy of the easement legal description, for Lot #21, from City records. 8.City records indicate there are two sanitary sewer manholes located on the property. Show the location of these manholes. 9.The sewer line shall be 6” from the main to the edge of the easement. A 6” cleanout shall be provided at the edge of the easement with a 12” locking CI lamphole cover. The sewer line can be reduced to 4” from this point to the house. 10.Show the water meter at the property line, as a water meter. What is currently shown could be mistaken for a cleanout. 11.What does the notation “string line” refer to? 12.Clearly label existing and proposed contours. The plan submitted is very busy and it is difficult to follow the topo lines. Please clarify. 13.The proposed contours indicate a driveway slope in excess of 14%. The Edmonds Community Development Code does not allow for a driveway slope to exceed 14% without first obtaining approval by the City DATE E-MAILED 2/8/07 PAGE(s) 2 Engineer. The maximum allowed driveway slope is 20%. Adjust the slope of the driveway to reflect a 14% grade or submit your request in writing to the City Engineer with an explanation as to why the required 14% slope cannot be achieved. 14.Provide top and bottom rockery elevations. The rockery cannot support a surcharge from the driveway. 15.Provide the lowest bottom of footing elevation at each step in the foundation. This information will be used to verify grading calculations. Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Theresa Umbaugh is your City contact for this project. Please contact me at 425-771-0220 or by e-mail at mcconnell@ci.edmonds.wa.us if you have specific questions regarding these plan corrections. DATE E-MAILED 2/8/07 PAGE(s) 2