20070104142521.pdfo� EDS City of Edmonds o Un PLAN REVIEW COMMENTS BUILDING DIVISION �sr. g90 (425) 771-0220 DATE: January 4, 2007 TO: Kristin Hanson hansondesign@hotmail.com FROM: Jenny Readwin, Plans Examier RE: Plan Check # 2006-0949 Project: Scott -Sayler Addtion Project Address: 646 Dayton St. During re -review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised pians/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) ok 2) ok 3) Response says it was redlined but I was unable to locate on either set ofplans. Show size and location of proposed attic access. 4) ok 5) ok 6) ok 7) ok 8) ok 9) Calculation was provided for triple joists but triple joists are not shown at all point load locations. Please clarify. There is a point load on the corner of the cantilevered floor joists from the 4x8 roof beams. Provide calculations to justify. 10) ok 11) Calculation is needed for cantilevered beam. Please provide. Clarify how DB 1 on sheet 9 (porch roof beam) will be supported at each end. Calculation is not for a cantilevered beam and calculations are for 6x8 and 6x 12 and plans have 6x6 or 4x8 options. Coordinate plans with calculations or provide additional calculations. 1.2) It is still unclear where the beam starts and stops and if a point load is placed on the cantilevered joists. If so show triple joists at this location. Otherwise clearly show posts or multiple studs and how all loads are carried to bearing. Specify how loads from 3 1/8x 10 1/2 GLB are carried to bearing at deck side. It appears to place a point load on the cantilevered floor joists. If this is the case provide calculations for floor joists to justify that they are adequate to carry additional loads. 13) Response states (4) sistered rim boards and this is not shown on the plans. I still don't think that will apply to the area I am specifying. That area in question is not the side that runs parallel with the joists but the opposite end where they would frame into the joists. Please clarify. Specify how deck joists will frame into cantilevered sunroom floor joists. If ledgered off this is non-conventional and calculation are required from EOR. 14) ok 15) ok 16) Still need signed for expoxy bolt installation. Special inspections are required for the following. Complete the enclosed special inspection agreement signed by the owner, the general contractor and the special inspector and submit to the City for approval prior to issuance. • Field Welding • Epoxy bolt installation (T4 holdowns) Page 2 of 2