,1 PLAN REVIEW COMMENTS
BUILDING DIVISION
�Sr S $go (425) 771-0220
DATE: January 8, 2007
TO: Vince Norberg
tnicholson@hertz.com
FROM: Jenny Readwin, Plans EX69
RE: Plan Check # 2006-0250A
Project: Nicholson Revision
Project Address: 703 Driftwood Ln
During review of the above noted revision, it was found that the following information, corrections,
or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents
(affected sheets only) with a written response to each of the above items to a Permit Coordinator.
1) Hobby room has a closet therefore it is considered a sleeping room and must have a smoke
detector and complying egress. Either completely remove closet or provide complying egress
window/door. If openings are made in shearwalls provide revised engineering stamped and
signed by Engineer of Record. Also note, egress openings can not open into garage areas.