20070110135219.pdfof cbo City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION FSI. S g90 (425) 771-0220 DATE: January 10, 2007 TO: Billy Wallace jhbconstruction@venzon.net FROM: Jenny Readwin, Plans Exa ne RE: Plan Check # 2006-1374 Project: Meinke Carport Enclosure Project Address: During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) The International Residential Code requires a continuous foundation under all exterior walls. Now that the carport is being enclose please provide foundation detail and plan for continuous foundation support around the exterior walls. See attached sample. SAMPLE SECTION VIEW (FOR CONVENTIONAL LIGHT -FRAME WOOD CONSTRUCTION) Roofing material type and weather barrier Roof Slope (e.g. 3:12) y Sheathing thickness, type, and nailing pattern (e.g. 112" CDX Plywood, 8d nails, 6" o.c. at edges and 12" o.c at field) Maintain 1" airspace with approved baffle Ceiling Insulation Gutter connected R -Value (e.g. R-30 batt) to tighlined \ downspout J Eave venting Three 2" holes per bay covered with 114" galvenized wire mesh Siding material type and weather barrier Sheathing thickness, type and nailing pattern (e.g. 1/2" CDX Plywood, 8d nails, 6" o.c. at edges and 12" o.c at field) fl' 1/2" x 10" anchor bolt with nut and washer spaced at 6' o.c. maximum, with min. 7" embedment, 2 bolts per piece within 12" of each end. Plate \ washers are required for each bolt (2" x 2" x 3116" thick) 6" minimum wood- j earth separation L 3rade shall slope away from _ Foundation walls minimum 6 riches within the first 10 Feet. Footing are drains require For all foundation walls that f _ enclose habitable or _— useable space below grade. See footing drain detail for requirements, Attachment j C1. VIII— Footings must be placed on firm, bearing, undisturbed soil LltemplbuildinglhandoutlsfrlsedionC.vsd updated 4106 Ridge Board size Manufactured Truss/Rafter size, spacing and lumber species/grade (e.g. 2x8 HF#2 rafters at 24" on center) Ceiling JoistfCollar Tie size, spacing and species Rafters/Trusses must be anchored to bearing wall with approved framing clips (See Typical Construction Connectors) Double top plate Wall Insulation R -value (e.g. R-19 kraft paper batts face stapled) Sheetrock thickness (e.g. 112" Sheetrock) Studs size, spacing and species (e.g. 2x6 HF#2 studs at 16" on tenter) DESIGN LOADS: Wind Speed: 80 mph Wind Exposure: B Seismic Zone: 3 Roof Snow Load: 25 psf Roof Dead Load: 15 psf Floor Live Load: 40 psf Floor Dead Load: 15 psf SCALE. 3/4"=V-0" Subfloor thickness, type, and nailing pattern (e.g. 3/4" CDX Plywood, 8d nails, 6" o.c. at edges Floor Insulation R -value and 12" o.c at field) (e.g. R-19 baits) Floor Joist size and spacing (e.g. 2x10 HF#2 at 16" on center) Size of pressure treated sill plate E (e.g. 2x6 pressure treated sill plate) E o E ami Eo E c 7 #4 rebar continuous (typ) .E o o .- 6 mil vapor barrier throughout - Z °r° .0 - v — n crawispace See chart on page 4 for minimum } _foundation footing and wall sizes ATTACHMENT C 12 Concrete foundation