Loading...
20070111113226.pdfo� ED,�o City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION �Slr. s g90 (425) 771-0220 DATE: January 11, 2007 TO: Don Miller Fax 425-481-8397 FROM: Jenny Readwin, Plans Exam' e . RE: Plan Check # 2007-0005 Project: Vicklund Carport Enclosure Project Address: 19515 94t' PI W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Site plan submitted is too small and hard to read. See attached copy of site plan from previous fence permit we had on file. Please modify this for proposed project. Please label as enclosing existing carport into garage. 2) Please expand floor plan to include attached residence with all room uses specified in rooms adjoining the garage (i.e. kitchen, living room, etc.). 3) Note garage/dwelling separation on plans. Minimum 112" sheetrock required on garage side of wall and 518" type X on the ceiling when there is habitable space above and minimum 20 minute rated or 13/8" solid core door. 4) One #4 vertical hooked rebar is required in the foundation at 4' on center. Please note on the section view. 5) Provide complete existing roof framing plan showing ridge, rafter size and spacing, existing carport postsibeams etc. to check spans and verify header loads. G) Specify all headers and posts or multiple studs on the framing plan. On the front of garage framing plan also show post or multiple studs supporting the garage door header. 7) Based on the framing plan I am unable to determine if the walls meet conventional wall bracing requirements because not wall dimensions are shown. In order to meet conventional construction walls next to garage door must be minimum 4" or an alternate braced wall panel of 2'-8" (see attached detail) is required. Please dimension all wall sections and. specify if an alternate braced wall panel is to be used. Alternate Braced Wall Panel fora 1 -story Structure (IRC R602.1.6) NOTE: This panel may be used in place of any braced wall panel required by IRC R602.10.4. For all other wall bracing that does not meet R602.10, lateral calculations stamped and signed by a Washington State Licensed Professional Engineer must be provided. #4 rebar con top and be inimum 318" thick sheathing ailed with 8d nails at 6" o.c. at ages and 12"o.c. in the field. Holdown with minimum 1800 lb. mcity. Note specific holdowns or ations on the plans for the ctor that meet the 1800# lent. Caution on minimum edge required foundation wall width, embedment requirement, etc.. hor bolts embedded a i of 7", spaced at panel Dints :ontinuous Foundation L:Stemp4building5handoutlgaragelGar abpw_vsd-8104 "TTACI-IIVIEIVT E