20070126085416.pdfor EDS City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
Fr. 3 a9° (425) 771.-0220
DATE: January 26, 2007
TO: Mary Grace Villasin
Maryvillasin8733@yahoo.com
FROM: Jenny Readwin, Plans Exam' er
RE: Plan Check 4 2007-0052
Project: Garage Conversion
Project Address: 7724 203' St SW
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised
plans/documents (affected sheets only) with a written response to each of the items below to a
Permit Coordinator.
1) Provide foundation plan showing existing and proposed to clarify if the foundation shown in the
typical wall section on sheet 2 applies all the way around the garage including where the garage
doors are currently. Building code requires a continuous foundation under all exterior walls.
2) Minimum 50 cfm fan is required in the proposed laundry room. Please note on plans.