20070131150529.pdfCity of Edmonds o� ��� PLAN REVIEW COMMENTS Efa.;� :.��„N BUILDING DIVISION �Sr, t091 (425) 771-0220 DATE: January 31, 2007 TO: Cramer Construction colincramer@hotmail.com FROM: Jenny Readwin, Plans Exam' e RE: Plan Check # 2006-1382 Project: Nguyen SFR Project Address: 8555 Talbot Rd. During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Reduced site plan provided is not scaled 1"=20' and it is illegible. Please provide new reduced site plan scaled no smaller than 1" = 20' on paper no larger than 8 %" x 14". 2) Show how island sink will be vented through the roof or with a loop vent as permitted by UPC 909.0.Air admittance valves are not permitted unless first approved by the Building Official under and alternate method per UPC 301.2. 3) Show size and location of crawlspace access for area below the guest room. 4) Provide attic ventilation calculations. 5) Gas fireplace in the master bedroom must be direct vent. Please not on floor plan. 6) Specify cfin rating for all exhaust fans (50 cfin min for bath, laundry and 100 cfin over kitchen stove). 7) An additional smoke detector is required in the hall outside bedrooms 2, 3 and 4. Please note on plans. 8) It appears that there will be a site built shower. Please provide shower pan construction detail . showing pan, material, drain, slope, etc. 9) Detail E/7 shows nails in the deck ledger. Per R502.2.1 nails subject to withdrawal are not permitted. Pleaser revise to lag bolts or screws and specify size and spacing and provide calculations to justify. 10) Per our Rockery handout any rockery located in a critical area must have plans designed consistent with ECDC Chapter 23.80 (including design calculations) and stamped by a Washington State Licensed Professional Engineer. 11) Soils report provided (Robert M. Pride, LLC Dated 11/22/2006) does not meet the minimum soils report requirements of IRC chapter 4 or IBC chapter 18. See attached for minimum report requirements. Please provide complete soils report. 12) See attached structural.comments from city consultant. Respond to each item in writing. Eagle Eye Consulting Engineers, P.S. PO Box 523 Olalla, WA 98359 hoytjeter@centurytel.net 360 874 0562 Fax 360 874 0591 To: JoAnne Zulauf 121 5th Avenue N Edmonds, WA 98020 Re: Nguyen Residence 8555 Talbot Road Edmonds, WA 98020 Thursday, January 18, 2007 Plan Review # 2006-1382 EECE # EDM 07-01 Structure Calculated Area S.F. Lower floor 834 Main floor 2200 tjpper floor 2167 Total 5201 arae 1 832 Garage 2 1045 Total 7078 Deck 297 Porches 203 Grand total 7578 Sprinklers 13D 5201 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficienciesicorrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 4 EECE#: EDM 07-01 Nguyen Residence STRUCTURAL CONEWENTS Sheet 7 MAIN FLOOR FRAMING PLAN: 1. EOR please specify the required joist hanger to be used at the deck framing. I was unable to find this in the drawings. IBC 2304.9.6 Sheet 10 BUILDING SECTION: 2. EOR please submit analysis for the retaining wall with a surcharge added to the design loads. Based on the location of the footing, there will be a surcharge that must be added to the analysis to resist this force. IBC 1806.1 3. EOR please provide analysis for the 4" slab to resist the horizontal force of the retaining wall. This is required to have a safety factor of 1.5. IBC 1806 Sheet S-1 ROOF FRAMING GRAVITY LOAD ENGINEERING: 4. EOR please specify the required connection of the beam to the post. One example location is at the covered deck beam R15. All that is specified is a 6x6 PT post W. Cap & Base. There are other locations as well, so please clearly specify all required connections. Sheet S-2 UPPER FLOOR FRAMING GRAVITY LOAD ENGINEERING: 5. EOR the design analysis assumes beam mark U13 is lateral braced. But there is not a floor system to brace the wall laterally. Modify analysis and drawing accordingly for this condition. NDS table 3.3.3 Sheet S-3 MAIN FLOOR FRAMING ENGINEERING: 6. EOR please clarify how the lateral loads are being transferred by the deck framing. Is X bracing, knee bracing or another method required to transfer the required lateral forces being used? Nothing is shown on the drawing for this toad path. 7. EOR please specify the required Banger to be used to support the joist_ All that I was able to find specified on the drawings was a note stating `manufactured metal hanger, typical'. The specific banger needs to be specified within the drawings. There is no way to check capacity without this information. 8. EOR please specify all required posts and post connections on the drawings. The post supporting the Glu -lam beams is one example,. I was able to find the reactions specified but not the physical connections. Sheet S-4 FOUNDATION PLAN ENGINEERING: Page 3 of 4 EECE#: EDM 07-01 Nguyen Residence 9. EOR please specify the required size of the footing with a mark U15. This footing is next to the 36" footing. . Sheet S-5 BASEMENT LATERAL ENGINEERING: 10. EOR please specify the required collector elements to drag the shear force into the shear walls. For example: No collector element for the shear walls was specified for the Simpson shear wall panels. Please add this to the drawings in order to verify the transfer of the lateral loads. Sheet D-1 GENERAL STRUCTURAL NOTES: 11. Retaining wall: Rigid insulation is shown between the slab and the wall. EOR please justify the rigid insulation to resist the horizontal forces at the base of the wall. Rigid insulations can not resist the required design force. The analysis submitted uses the slab to resist the sliding force. IBC 1806 12. EOR please submit analysis for a retaining wall of 10'6" as shown in the retaining wall schedule. The submitted analysis only goes up to 9'6" maximum. 13. EOR please modify the retaining wall schedule to match the analysis. For example, the retaining wall design is for 7.5 feet with a wall height above soil to be only 6". But based on the schedule the wail height is 8.5 feet and not 8 feet as assumed in the analysis. The other walls in the schedule have the same issue. Please modify analysis or drawings accordingly. 14. EOR based on the reactions at the top of the wall the A34 will not resist the design force. Submit analysis to justify and modify accordingly. For example, for the 10 foot wall the required force to resist is 1,429 pound per foot of wall. With blocking at 24 inches OIC and (2) A35 at each block. The maximum force this will resist is 450 pounds/ anchor. Therefore, the maximum force it can resist is 900 pounds. Please modify design and/or analysis accordingly. 15. For A35 anchors to be installed on both sides, the minimum size joist thickness can not be less then 3". The drawings specify I Y2:"size members. Please modify accordingly. Simpson catalog A35 footnote 1. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Page 4 of 4 EECE#: EDM 07-01 Nguyen Residence Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874-0552 between 8:00 a.m. and 5:40 p.m. By: Hoyt Jeter, P.E. President SOILS INVESTIGATION AND/OR REPORT (Cont.) The classification of bearing soil at the site must be determined and called out on the plans. The following information from IRC Table R401.4.1, will assist individuals in determining the soil classification of the building site. The Building Official may require this classification to be made by a Washington State licensed Geotechnical Engineer or Engineering Geologist in a written report when soils are not adaptable to conventional spread footings or if allowable foundation and lateral pressures do not meet the values set forth in the table below. The allowable foundation and lateral pressures may not exceed the values in this table, unless data to substantiate the use of higher values is submitted. Sidehill or steep slope construction IS NOT considered conventional construction and soils reports are required for lots with 15% or more slope, unless determined unnecessary by the Building Official, For more specific and technical information on soil capacity, foundation design and construction components, refer to IBC Chapter 18 and IRC Chapter 4 or contact a professional engineer. TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATFRIALS' For SI: 1 pound per square foot= 0.0474 kN/m2. a. When soil tests are required by Section R401.4, the allowable bearing capacities of the sail shall be part of the recommendations. b. Where the building official determines that in-place soils with an allowable bearing capacity of less than 1,500 psf are likely to he present at the site, the allowable bearing capacity shall be determined by a soils investigation. When soils reports are required, they shall include the following: 1. A plot plan showing the location of test borings and/or excavations. 2. A complete record of the soil samples. 3. A record of the soils profile. 4. Elevation of the water table, if encountered. 5. Recommendations for foundation Type and design criteria, including but not limited to: bearing capacity of natural or compacted soil; provisions to mitigate the effects of expansive soils; mitigation of the effects of liquefaction, differential settlement an carrying soil strength, the effects of adjacent loads, and foundation drainage. 6. Expected total and differential settlement. 7. Pile and pier foundation information in accordance with IBC Section 1808.2.2. 8. Special design and construction provisions for footings or foundations founded on expansive soils, as necessary. 9. Compacted fill material properties and testing in accordance with IBC Section 1803.5. NOTE: Report recommendations shall be incorporated into the foundation design 4. DRAINAGE PLAN (See Handout #E72) Development of over 2,000 square feet of new impervious area since July 1977 requires an on-site drainage system. Impervious area includes: building pad with cave overhangs, paved or graveled areas, solid surface decks, patios, walkways, breezeways, awnings, accessory structures, sidewalks, and driveways. Submit three (3) drainage plans, scaled 1"-20', showing all impervious area with square footages as well as the location of the proposed drainage detention system. Attach three (3) copies of the drainage worksheet (See Handout #E72). Note: The plan must provide for temporary and permanent erosion control and must include footing drain details. 3 L:ITEMPIBUILD1NGIHANT)0UT ICODESISFR B73.DOC Revised 5106 LOAD-BEARING PRESSURE CLASS OF MATERIAL(pounds per square foot Crystalline bedrock 12,000 Sedimentary and foliated rock 4,000 Sandy gravel and/or gravel GW and GP) 3,000 Sand, silty sand, clayey sand, silty gravel and clayey gravel (SW, SP, SM, SC, GM and GC) 2,000 Clay, sandy clay, silty clay, clayey silt, silt and sandy silt (Cl, ML, MH and CH) 1,500s For SI: 1 pound per square foot= 0.0474 kN/m2. a. When soil tests are required by Section R401.4, the allowable bearing capacities of the sail shall be part of the recommendations. b. Where the building official determines that in-place soils with an allowable bearing capacity of less than 1,500 psf are likely to he present at the site, the allowable bearing capacity shall be determined by a soils investigation. When soils reports are required, they shall include the following: 1. A plot plan showing the location of test borings and/or excavations. 2. A complete record of the soil samples. 3. A record of the soils profile. 4. Elevation of the water table, if encountered. 5. Recommendations for foundation Type and design criteria, including but not limited to: bearing capacity of natural or compacted soil; provisions to mitigate the effects of expansive soils; mitigation of the effects of liquefaction, differential settlement an carrying soil strength, the effects of adjacent loads, and foundation drainage. 6. Expected total and differential settlement. 7. Pile and pier foundation information in accordance with IBC Section 1808.2.2. 8. Special design and construction provisions for footings or foundations founded on expansive soils, as necessary. 9. Compacted fill material properties and testing in accordance with IBC Section 1803.5. NOTE: Report recommendations shall be incorporated into the foundation design 4. DRAINAGE PLAN (See Handout #E72) Development of over 2,000 square feet of new impervious area since July 1977 requires an on-site drainage system. Impervious area includes: building pad with cave overhangs, paved or graveled areas, solid surface decks, patios, walkways, breezeways, awnings, accessory structures, sidewalks, and driveways. Submit three (3) drainage plans, scaled 1"-20', showing all impervious area with square footages as well as the location of the proposed drainage detention system. Attach three (3) copies of the drainage worksheet (See Handout #E72). Note: The plan must provide for temporary and permanent erosion control and must include footing drain details. 3 L:ITEMPIBUILD1NGIHANT)0UT ICODESISFR B73.DOC Revised 5106