20070206160756.pdf01� EDS City of Edmonds rf} PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: February 6, 2007 TO: Doug and Claudine MacDonald. dougandclaudine@gmail.com FROM: Jenny Readwin, Plans Ex ine RE: Plan Check # 2006-1279 Project: MacDonald Addition/Remodel Project Address: 534 2nd Ave N During re -review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) ok 2) ok 3) ok 4) 2/6/47 Response says see note 16 but note 16 does not address garage/dwelling separation and I could not find any other note in the garage that takes care of this correction. Still need. Note garage/dwelling separation on plans. Minimum 1/z" sheetrock required on garage side of wall and 518" type X on the ceiling when there is habitable space above and minimum 20 minute rated or 13/8" solid core door. 5) ok 6) ok 7) ok 8) ok 9) ok 10) ok 11) ok 12) ok 13) ok 14) ok 15) ok 16) ok 17) ok 18) ok 19) 2/6/07 Note 23 was added but it is still not called out or shown at the front porch area. Please show footing on the plan and reference note 23. Clarify on the foundation how the front porch 4x8 beam will be supported. Currently nothing is shown. 20) 2/6/07 Will need prior to permit issuance. Special inspections are required for the following. Complete the enclosed special inspection agreement signed by the owner, the general contractor and the special inspector and submit to the City for approval prior to issuance. • Kwick Bolts • Epoxy 21) 2/6/07 New: Per Gina Coccia's comments from the Planning Division dated January 2, 2007 there is no approval for an Accessory Dwelling Unit. New plans removed references on the floor plan to the ADU but some of the notes still reference the Accessory Dwelling Unit (i.e. note 16 on sheet 3). If approval for the ADU isnot being obtained please remove all references on the plans. Also this area must be accessible from the house. As shown this is still an accessory dwelling unit. Also, covenant will need to be recorded. Page 2 of 2